Changes for page LT-22222-LA -- LoRa I/O Controller User Manual
Last modified by Kilight Cao on 2025/07/03 15:34
From version 59.1
edited by Kilight Cao
on 2025/07/03 15:34
on 2025/07/03 15:34
Change comment:
There is no comment for this version
To version 55.2
edited by Kilight Cao
on 2025/07/03 15:07
on 2025/07/03 15:07
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -29,8 +29,6 @@ 29 29 30 30 ((( 31 31 With the LT-22222-LA I/O Controller, users can transmit data over ultra-long distances with low power consumption using LoRa, a spread-spectrum modulation technique derived from chirp spread spectrum (CSS) technology that operates on license-free ISM bands. 32 - 33 -(% style="color:blue" %)**LT-22222-LA I/O Controller**(%%) support (% style="color:blue" %)**OTA upgrade**(%%) via private LoRa protocol for easy maintaining. 34 34 ))) 35 35 36 36 ((( ... ... @@ -98,7 +98,7 @@ 98 98 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869 99 99 * AT Commands to change parameters 100 100 * Remotely configure parameters via LoRaWAN Downlink 101 -* SupportwirelessOTAupdatefirmware99 +* Firmware upgradable via program port 102 102 * Counting 103 103 104 104 == 1.4 Applications == ... ... @@ -173,7 +173,7 @@ 173 173 == 2.3 Connecting LT-22222-LA to a Power Source == 174 174 175 175 176 -The LT-22222-L AI/O Controller can be powered by a **7–24V DC** power source. Connect your power supply’s **positive wire** to the **VIN** and the **negative wire** to the **GND** screw terminals. The power indicator **(PWR) LED** will turn on when the device is properly powered.174 +The LT-22222-L I/O Controller can be powered by a **7–24V DC** power source. Connect your power supply’s **positive wire** to the **VIN** and the **negative wire** to the **GND** screw terminals. The power indicator **(PWR) LED** will turn on when the device is properly powered. 177 177 178 178 {{warning}} 179 179 **We recommend that you power on the LT-22222-LA after adding its registration information to the LoRaWAN network server. Otherwise, the device will continuously send join-request messages to attempt to join a LoRaWAN network but will fail.** ... ... @@ -508,10 +508,6 @@ 508 508 509 509 510 510 511 - 512 - 513 - 514 - 515 515 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 516 516 517 517 ... ... @@ -550,10 +550,6 @@ 550 550 551 551 552 552 553 - 554 - 555 - 556 - 557 557 ((( 558 558 **To activate this mode, run the following AT commands:** 559 559 ))) ... ... @@ -648,10 +648,6 @@ 648 648 649 649 650 650 651 - 652 - 653 - 654 - 655 655 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 656 656 657 657 ... ... @@ -714,10 +714,6 @@ 714 714 715 715 716 716 717 - 718 - 719 - 720 - 721 721 === 3.3.6 AT+ADDMOD~=6 (Trigger Mode, Optional) === 722 722 723 723 ... ... @@ -2298,10 +2298,6 @@ 2298 2298 2299 2299 2300 2300 2301 - 2302 - 2303 - 2304 - 2305 2305 (% style="color:blue" %)**Example 4**(%%): Connecting to a Dry Contact sensor 2306 2306 2307 2307 From the DI port circuit above, activating the photocoupler requires a voltage difference between the DI+ and DI- ports. However, the Dry Contact sensor is a passive component and cannot provide this voltage difference on its own. ... ... @@ -2569,52 +2569,78 @@ 2569 2569 == 5.1 Counting how many objects pass through the flow line == 2570 2570 2571 2571 2572 -See [[How to set up to setup counting for objects passing through the flow line>> https://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/How%20to%20set%20up%20to%20count%20objects%20pass%20in%20flow%20line/]].2550 +See [[How to set up to setup counting for objects passing through the flow line>>How to set up to count objects pass in flow line]]. 2573 2573 2574 2574 2575 -= 6. OTAFirmware update=2553 += 6. FAQ = 2576 2576 2577 2577 2578 -(% class="wikigeneratedid" %) 2579 -User can change firmware LT-22222-LA to: 2556 +This section contains some frequently asked questions, which can help you resolve common issues and find solutions quickly. 2580 2580 2581 -* Change Frequency band/ region. 2582 -* Update with new features. 2583 -* Fix bugs. 2584 2584 2585 - Firmwareandchangelogcanbedownloadedfrom: **[[Firmwaredownload link>>https://www.dropbox.com/sh/fis3g6nmhv0eokg/AAC6BcCZaX4BdqZkduUvZ3jIa?dl=0]]**2559 +== 6.1 How to update the firmware? == 2586 2586 2587 2587 2588 - Methods to UpdateFirmware:2562 +Dragino frequently releases firmware updates for the LT-22222-L. Updating your LT-22222-L with the latest firmware version helps to: 2589 2589 2590 -* (Recommanded way) OTA firmware update via wireless : **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]** 2591 -* Update through UART TTL interface : **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 2564 +* Support new features 2565 +* Fix bugs 2566 +* Change LoRaWAN frequency bands 2592 2592 2568 +You will need the following things before proceeding: 2593 2593 2570 +* 3.5mm programming cable (included with the LT-22222-L as an additional accessory) 2571 +* USB to TTL adapter/converter 2572 +* Download and install the [[STM32 Flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. (replaced by STM32CubeProgrammer) 2573 +* Download the latest firmware image from [[LT-22222-L firmware image files>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AACrbrDN0AqLHbBat0ViWx5Da/LT-22222-L/Firmware?dl=0&subfolder_nav_tracking=1]]. Check the file name of the firmware to find the correct region. 2594 2594 2595 -= 7. FAQ = 2575 +{{info}} 2576 +As of this writing, the latest firmware version available for the LT-22222-L is v1.6.1. 2577 +{{/info}} 2596 2596 2579 +Below is the hardware setup for uploading a firmware image to the LT-22222-L: 2597 2597 2598 -This section contains some frequently asked questions, which can help you resolve common issues and find solutions quickly. 2599 2599 2600 2600 2601 2601 2584 +Start the STM32 Flash Loader and choose the correct COM port to update. 2585 + 2602 2602 ((( 2603 2603 ((( 2604 - ==7.2 Howto changethe LoRaWAN frequencyband/region?==2588 +(% style="color:blue" %)**For LT-22222-LA**(%%): 2605 2605 2590 +Hold down the **PRO** button, then briefly press the **RST** button. The **DO1** LED will change from OFF to ON. When the **DO1** LED is ON, it indicates that the device is in firmware download mode. 2591 +))) 2592 + 2606 2606 2607 2607 ))) 2595 + 2596 + 2597 + 2598 + 2599 + 2600 + 2601 + 2602 +(% style="color:red" %)**Note**(%%): If you have lost the programming cable, you can make one from a 3.5 mm cable. The pin mapping is as follows: 2603 + 2604 + 2605 + 2606 +((( 2607 +((( 2608 +== 6.2 How to change the LoRaWAN frequency band/region? == 2609 + 2610 + 2608 2608 ))) 2612 +))) 2609 2609 2610 2610 ((( 2611 -You can follow the introductions on [[how to upgrade the image>> doc:.https\:wiki\.dragino\.comxwikibinviewMainUser%20Manual%20for%20LoRaWAN%20End%20NodesLT-22222-LA#H6\.OTAFirmwareupdate.WebHome]]. When downloading, select the required image file.2615 +You can follow the introductions on [[how to upgrade the image>>||anchor="H6.1Howtoupdatethefirmware3F"]]. When downloading, select the required image file. 2612 2612 ))) 2613 2613 2614 2614 ((( 2615 2615 2616 2616 2617 -== 7.3 How to set up LT-22222-LA to work with a Single Channel Gateway, such as LG01/LG02? ==2621 +== 6.3 How to set up LT-22222-LA to work with a Single Channel Gateway, such as LG01/LG02? == 2618 2618 2619 2619 2620 2620 ))) ... ... @@ -2644,7 +2644,7 @@ 2644 2644 ))) 2645 2645 2646 2646 {{warning}} 2647 -Ensure that the Device Address (DevAddr) and the two keys match between the LT-22222-L Aand The Things Stack. You can modify them either in The Things Stack or on the LT-22222-LAto make them align. In The Things Stack, you can configure the NwkSKey and AppSKey on the settings page, but note that the Device Address is generated by The Things Stack.2651 +Ensure that the Device Address (DevAddr) and the two keys match between the LT-22222-L and The Things Stack. You can modify them either in The Things Stack or on the LT-22222-L to make them align. In The Things Stack, you can configure the NwkSKey and AppSKey on the settings page, but note that the Device Address is generated by The Things Stack. 2648 2648 {{/warning}} 2649 2649 2650 2650 ... ... @@ -2688,13 +2688,13 @@ 2688 2688 [[image:1653360498588-932.png]] 2689 2689 2690 2690 2691 -== 7.4 How to change the uplink interval? ==2695 +== 6.4 How to change the uplink interval? == 2692 2692 2693 2693 2694 2694 Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]] 2695 2695 2696 2696 2697 -== 7.5 Can I see the counting event in the serial output? ==2701 +== 6.5 Can I see the counting event in the serial output? == 2698 2698 2699 2699 2700 2700 ((( ... ... @@ -2705,7 +2705,7 @@ 2705 2705 ))) 2706 2706 2707 2707 ((( 2708 -== 7.6 Why does the relay output default to an open relay after the LT-22222-LA is powered off? ==2712 +== 6.6 Why does the relay output default to an open relay after the LT-22222-LA is powered off? == 2709 2709 2710 2710 2711 2711 * If the device is not properly shut down and is directly powered off. ... ... @@ -2713,7 +2713,7 @@ 2713 2713 * In modes 2 to 5, the DO/RO status and pulse count are saved to flash memory. 2714 2714 * After a restart, the status before the power failure will be read from Flash. 2715 2715 2716 -== 7.7 Can I set up LT-22222-LA as an NC (Normally Closed) relay? ==2720 +== 6.7 Can I set up LT-22222-LA as an NC (Normally Closed) relay? == 2717 2717 2718 2718 2719 2719 The LT-22222-LA's built-in relay is Normally Open (NO). You can use an external relay to achieve a Normally Closed (NC) configuration. The circuit diagram is shown below: ... ... @@ -2723,13 +2723,13 @@ 2723 2723 2724 2724 2725 2725 2726 -== 7.8 Why does the LT-22222-LA always report 15.585V when measuring the AVI? ==2730 +== 6.8 Why does the LT-22222-LA always report 15.585V when measuring the AVI? == 2727 2727 2728 2728 2729 2729 It is likely that the GND is not connected during the measurement, or that the wire connected to the GND is loose. 2730 2730 2731 2731 2732 -= 8. Troubleshooting =2736 += 7. Troubleshooting = 2733 2733 2734 2734 2735 2735 This section provides some known troubleshooting tips. ... ... @@ -2739,7 +2739,7 @@ 2739 2739 2740 2740 ((( 2741 2741 ((( 2742 -== 8.1 Downlink isn't working. How can I solve this? ==2746 +== 7.1 Downlink isn't working. How can I solve this? == 2743 2743 2744 2744 2745 2745 ))) ... ... @@ -2752,7 +2752,7 @@ 2752 2752 ((( 2753 2753 2754 2754 2755 -== 8.2 Having trouble uploading an image? ==2759 +== 7.2 Having trouble uploading an image? == 2756 2756 2757 2757 2758 2758 ))) ... ... @@ -2764,7 +2764,7 @@ 2764 2764 ((( 2765 2765 2766 2766 2767 -== 8.3 Why can't I join TTN in the US915 /AU915 bands? ==2771 +== 7.3 Why can't I join TTN in the US915 /AU915 bands? == 2768 2768 2769 2769 2770 2770 ))) ... ... @@ -2774,7 +2774,7 @@ 2774 2774 ))) 2775 2775 2776 2776 2777 -== 8.4 Why can the LT-22222-LA perform uplink normally, but cannot receive downlink? ==2781 +== 7.4 Why can the LT-22222-LA perform uplink normally, but cannot receive downlink? == 2778 2778 2779 2779 2780 2780 The FCD count of the gateway is inconsistent with the FCD count of the node, causing the downlink to remain in the queue. ... ... @@ -2781,10 +2781,10 @@ 2781 2781 Use this command to synchronize their counts: [[Resets the downlink packet count>>||anchor="H3.4.2.23Resettingthedownlinkpacketcount"]] 2782 2782 2783 2783 2784 -= 9. Ordering information =2788 += 8. Ordering information = 2785 2785 2786 2786 2787 -(% style="color:#4f81bd" %)**LT-22222-L A-XXX:**2791 +(% style="color:#4f81bd" %)**LT-22222-L-XXX:** 2788 2788 2789 2789 (% style="color:#4f81bd" %)**XXX:** 2790 2790 ... ... @@ -2798,13 +2798,13 @@ 2798 2798 * (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2799 2799 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2800 2800 2801 -= 10. Package information =2805 += 9. Package information = 2802 2802 2803 2803 2804 2804 (% style="color:#037691" %)**Package Includes**: 2805 2805 2806 -* 1 x LT-22222-L AI/O Controller2807 -* 1 x LoRa antenna matched to the frequency of the LT-22222-L A2810 +* 1 x LT-22222-L I/O Controller 2811 +* 1 x LoRa antenna matched to the frequency of the LT-22222-L 2808 2808 * 1 x bracket for DIN rail mounting 2809 2809 * 1 x 3.5 mm programming cable 2810 2810 ... ... @@ -2813,7 +2813,7 @@ 2813 2813 * Package Size / pcs : 145×80×50 mm 2814 2814 * Weight / pcs : 180 g 2815 2815 2816 -= 1 1. Support =2820 += 10. Support = 2817 2817 2818 2818 2819 2819 * ((( ... ... @@ -2825,7 +2825,7 @@ 2825 2825 2826 2826 ))) 2827 2827 2828 -= 1 2. Reference =2832 += 11. Reference = 2829 2829 2830 2830 2831 2831 * LT-22222-LA: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]