Changes for page LT-22222-LA -- LoRa I/O Controller User Manual
Last modified by Kilight Cao on 2025/07/03 15:34
From version 57.2
edited by Kilight Cao
on 2025/07/03 15:28
on 2025/07/03 15:28
Change comment:
There is no comment for this version
To version 57.4
edited by Kilight Cao
on 2025/07/03 15:30
on 2025/07/03 15:30
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -29,6 +29,8 @@ 29 29 30 30 ((( 31 31 With the LT-22222-LA I/O Controller, users can transmit data over ultra-long distances with low power consumption using LoRa, a spread-spectrum modulation technique derived from chirp spread spectrum (CSS) technology that operates on license-free ISM bands. 32 + 33 +SN50V3-LB/LS has a **built-in BLE module**, user can configure the sensor remotely via Mobile Phone. It also support **OTA upgrade** via private LoRa protocol for easy maintaining. 32 32 ))) 33 33 34 34 ((( ... ... @@ -2682,13 +2682,13 @@ 2682 2682 [[image:1653360498588-932.png]] 2683 2683 2684 2684 2685 -== 6.4 How to change the uplink interval? ==2687 +== 7.4 How to change the uplink interval? == 2686 2686 2687 2687 2688 2688 Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]] 2689 2689 2690 2690 2691 -== 6.5 Can I see the counting event in the serial output? ==2693 +== 7.5 Can I see the counting event in the serial output? == 2692 2692 2693 2693 2694 2694 ((( ... ... @@ -2699,7 +2699,7 @@ 2699 2699 ))) 2700 2700 2701 2701 ((( 2702 -== 6.6 Why does the relay output default to an open relay after the LT-22222-LA is powered off? ==2704 +== 7.6 Why does the relay output default to an open relay after the LT-22222-LA is powered off? == 2703 2703 2704 2704 2705 2705 * If the device is not properly shut down and is directly powered off. ... ... @@ -2707,7 +2707,7 @@ 2707 2707 * In modes 2 to 5, the DO/RO status and pulse count are saved to flash memory. 2708 2708 * After a restart, the status before the power failure will be read from Flash. 2709 2709 2710 -== 6.7 Can I set up LT-22222-LA as an NC (Normally Closed) relay? ==2712 +== 7.7 Can I set up LT-22222-LA as an NC (Normally Closed) relay? == 2711 2711 2712 2712 2713 2713 The LT-22222-LA's built-in relay is Normally Open (NO). You can use an external relay to achieve a Normally Closed (NC) configuration. The circuit diagram is shown below: ... ... @@ -2717,13 +2717,13 @@ 2717 2717 2718 2718 2719 2719 2720 -== 6.8 Why does the LT-22222-LA always report 15.585V when measuring the AVI? ==2722 +== 7.8 Why does the LT-22222-LA always report 15.585V when measuring the AVI? == 2721 2721 2722 2722 2723 2723 It is likely that the GND is not connected during the measurement, or that the wire connected to the GND is loose. 2724 2724 2725 2725 2726 -= 7. Troubleshooting =2728 += 8. Troubleshooting = 2727 2727 2728 2728 2729 2729 This section provides some known troubleshooting tips. ... ... @@ -2733,7 +2733,7 @@ 2733 2733 2734 2734 ((( 2735 2735 ((( 2736 -== 7.1 Downlink isn't working. How can I solve this? ==2738 +== 8.1 Downlink isn't working. How can I solve this? == 2737 2737 2738 2738 2739 2739 ))) ... ... @@ -2746,7 +2746,7 @@ 2746 2746 ((( 2747 2747 2748 2748 2749 -== 7.2 Having trouble uploading an image? ==2751 +== 8.2 Having trouble uploading an image? == 2750 2750 2751 2751 2752 2752 ))) ... ... @@ -2758,7 +2758,7 @@ 2758 2758 ((( 2759 2759 2760 2760 2761 -== 7.3 Why can't I join TTN in the US915 /AU915 bands? ==2763 +== 8.3 Why can't I join TTN in the US915 /AU915 bands? == 2762 2762 2763 2763 2764 2764 ))) ... ... @@ -2768,7 +2768,7 @@ 2768 2768 ))) 2769 2769 2770 2770 2771 -== 7.4 Why can the LT-22222-LA perform uplink normally, but cannot receive downlink? ==2773 +== 8.4 Why can the LT-22222-LA perform uplink normally, but cannot receive downlink? == 2772 2772 2773 2773 2774 2774 The FCD count of the gateway is inconsistent with the FCD count of the node, causing the downlink to remain in the queue. ... ... @@ -2775,7 +2775,7 @@ 2775 2775 Use this command to synchronize their counts: [[Resets the downlink packet count>>||anchor="H3.4.2.23Resettingthedownlinkpacketcount"]] 2776 2776 2777 2777 2778 -= 8. Ordering information =2780 += 9. Ordering information = 2779 2779 2780 2780 2781 2781 (% style="color:#4f81bd" %)**LT-22222-LA-XXX:** ... ... @@ -2792,7 +2792,7 @@ 2792 2792 * (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2793 2793 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2794 2794 2795 -= 9. Package information =2797 += 10. Package information = 2796 2796 2797 2797 2798 2798 (% style="color:#037691" %)**Package Includes**: ... ... @@ -2807,7 +2807,7 @@ 2807 2807 * Package Size / pcs : 145×80×50 mm 2808 2808 * Weight / pcs : 180 g 2809 2809 2810 -= 1 0. Support =2812 += 11. Support = 2811 2811 2812 2812 2813 2813 * ((( ... ... @@ -2819,7 +2819,7 @@ 2819 2819 2820 2820 ))) 2821 2821 2822 -= 1 1. Reference =2824 += 12. Reference = 2823 2823 2824 2824 2825 2825 * LT-22222-LA: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]