Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -171,7 +171,7 @@ 171 171 == 2.3 Connecting LT-22222-LA to a Power Source == 172 172 173 173 174 -The LT-22222-L I/O Controller can be powered by a **7–24V DC** power source. Connect your power supply’s **positive wire** to the **VIN** and the **negative wire** to the **GND** screw terminals. The power indicator **(PWR) LED** will turn on when the device is properly powered. 174 +The LT-22222-LA I/O Controller can be powered by a **7–24V DC** power source. Connect your power supply’s **positive wire** to the **VIN** and the **negative wire** to the **GND** screw terminals. The power indicator **(PWR) LED** will turn on when the device is properly powered. 175 175 176 176 {{warning}} 177 177 **We recommend that you power on the LT-22222-LA after adding its registration information to the LoRaWAN network server. Otherwise, the device will continuously send join-request messages to attempt to join a LoRaWAN network but will fail.** ... ... @@ -507,6 +507,8 @@ 507 507 508 508 509 509 510 + 511 + 510 510 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 511 511 512 512 ... ... @@ -546,6 +546,8 @@ 546 546 547 547 548 548 551 + 552 + 549 549 ((( 550 550 **To activate this mode, run the following AT commands:** 551 551 ))) ... ... @@ -641,6 +641,8 @@ 641 641 642 642 643 643 648 + 649 + 644 644 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 645 645 646 646 ... ... @@ -704,6 +704,8 @@ 704 704 705 705 706 706 713 + 714 + 707 707 === 3.3.6 AT+ADDMOD~=6 (Trigger Mode, Optional) === 708 708 709 709 ... ... @@ -2285,6 +2285,8 @@ 2285 2285 2286 2286 2287 2287 2296 + 2297 + 2288 2288 (% style="color:blue" %)**Example 4**(%%): Connecting to a Dry Contact sensor 2289 2289 2290 2290 From the DI port circuit above, activating the photocoupler requires a voltage difference between the DI+ and DI- ports. However, the Dry Contact sensor is a passive component and cannot provide this voltage difference on its own. ... ... @@ -2552,18 +2552,12 @@ 2552 2552 == 5.1 Counting how many objects pass through the flow line == 2553 2553 2554 2554 2555 -See [[How to set up to setup counting for objects passing through the flow line>>How 2565 +See [[How to set up to setup counting for objects passing through the flow line>>https://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/How%20to%20set%20up%20to%20count%20objects%20pass%20in%20flow%20line/]]. 2556 2556 2557 2557 2558 -= 6. FAQ=2568 += 6. OTA Firmware update = 2559 2559 2560 2560 2561 -This section contains some frequently asked questions, which can help you resolve common issues and find solutions quickly. 2562 - 2563 - 2564 -== 6.1 OTA Firmware update == 2565 - 2566 - 2567 2567 (% class="wikigeneratedid" %) 2568 2568 User can change firmware LT-22222-LA to: 2569 2569 ... ... @@ -2581,10 +2581,17 @@ 2581 2581 2582 2582 2583 2583 2588 += 7. FAQ = 2584 2584 2590 + 2591 +This section contains some frequently asked questions, which can help you resolve common issues and find solutions quickly. 2592 + 2593 + 2594 + 2595 + 2585 2585 ((( 2586 2586 ((( 2587 -== 6.2 How to change the LoRaWAN frequency band/region? ==2598 +== 7.2 How to change the LoRaWAN frequency band/region? == 2588 2588 2589 2589 2590 2590 ))) ... ... @@ -2591,13 +2591,13 @@ 2591 2591 ))) 2592 2592 2593 2593 ((( 2594 -You can follow the introductions on [[how to upgrade the image>> ||anchor="H6.1Howtoupdatethefirmware3F"]]. When downloading, select the required image file.2605 +You can follow the introductions on [[how to upgrade the image>>doc:]]. When downloading, select the required image file. 2595 2595 ))) 2596 2596 2597 2597 ((( 2598 2598 2599 2599 2600 -== 6.3 How to set up LT-22222-LA to work with a Single Channel Gateway, such as LG01/LG02? ==2611 +== 7.3 How to set up LT-22222-LA to work with a Single Channel Gateway, such as LG01/LG02? == 2601 2601 2602 2602 2603 2603 ))) ... ... @@ -2627,7 +2627,7 @@ 2627 2627 ))) 2628 2628 2629 2629 {{warning}} 2630 -Ensure that the Device Address (DevAddr) and the two keys match between the LT-22222-L and The Things Stack. You can modify them either in The Things Stack or on the LT-22222-L to make them align. In The Things Stack, you can configure the NwkSKey and AppSKey on the settings page, but note that the Device Address is generated by The Things Stack. 2641 +Ensure that the Device Address (DevAddr) and the two keys match between the LT-22222-LA and The Things Stack. You can modify them either in The Things Stack or on the LT-22222-LA to make them align. In The Things Stack, you can configure the NwkSKey and AppSKey on the settings page, but note that the Device Address is generated by The Things Stack. 2631 2631 {{/warning}} 2632 2632 2633 2633