... ... @@ -2704,11 +2704,16 @@ 2704 2704 You can run the AT command **AT+DEBUG** to view the counting event in the serial output. If the firmware is too old and doesn’t support AT+DEBUG, update to the latest firmware first. 2705 2705 2706 2706 2707 +== 6.6 Can I use point-to-point communication with LT-22222-L? == 2708 + 2709 + 2710 +Yes, you can. Please refer to the [[Point-to-Point Communication of LT-22222-L>>https://wiki.dragino.com/xwiki/bin/view/Main/%20Point%20to%20Point%20Communication%20of%20LT-22222-L/]] page. The firmware that supports point-to-point communication can be found [[here>>https://github.com/dragino/LT-22222-L/releases]]. 2711 + 2707 2707 2708 2708 ))) 2709 2709 2710 2710 ((( 2711 -== 6. 6Why does the relay output default to an open relay after the LT-22222-LAis powered off? ==2716 +== 6.7 Why does the relay output default to an open relay after the LT-22222-L is powered off? == 2712 2712 2713 2713 2714 2714 * If the device is not properly shut down and is directly powered off. ... ... @@ -2716,19 +2716,23 @@ 2716 2716 * In modes 2 to 5, the DO/RO status and pulse count are saved to flash memory. 2717 2717 * After a restart, the status before the power failure will be read from Flash. 2718 2718 2719 -== 6. 7Can I set up LT-22222-LAas an NC (Normally Closed) relay? ==2724 +== 6.8 Can I set up LT-22222-L as an NC (Normally Closed) relay? == 2720 2720 2721 2721 2722 -The LT-22222-L A's built-in relay is Normally Open (NO). You can use an external relay to achieve a Normally Closed (NC) configuration. The circuit diagram is shown below:2727 +The LT-22222-L's built-in relay is Normally Open (NO). You can use an external relay to achieve a Normally Closed (NC) configuration. The circuit diagram is shown below: 2723 2723 2724 -[[image:image-20221006170630-1.png]] 2725 2725 2726 2726 2727 2727 2732 +== 6.9 Can the LT-22222-L save the RO state? == 2728 2728 2729 -== 6.9 Why does the LT-22222-LA always report 15.585V when measuring the AVI? == 2730 2730 2735 +To enable this feature, the firmware version must be 1.6.0 or higher. 2731 2731 2737 + 2738 +== 6.10 Why does the LT-22222-L always report 15.585V when measuring the AVI? == 2739 + 2740 + 2732 2732 It is likely that the GND is not connected during the measurement, or that the wire connected to the GND is loose. 2733 2733 2734 2734