Changes for page LT-22222-LA -- LoRa I/O Controller User Manual
Last modified by Kilight Cao on 2025/07/03 15:34
From version 54.1
edited by Kilight Cao
on 2025/07/03 15:03
on 2025/07/03 15:03
Change comment:
Uploaded new attachment "image-20221006170630-1.png", version {1}
To version 54.2
edited by Kilight Cao
on 2025/07/03 15:04
on 2025/07/03 15:04
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2704,16 +2704,11 @@ 2704 2704 You can run the AT command **AT+DEBUG** to view the counting event in the serial output. If the firmware is too old and doesn’t support AT+DEBUG, update to the latest firmware first. 2705 2705 2706 2706 2707 -== 6.6 Can I use point-to-point communication with LT-22222-L? == 2708 - 2709 - 2710 -Yes, you can. Please refer to the [[Point-to-Point Communication of LT-22222-L>>https://wiki.dragino.com/xwiki/bin/view/Main/%20Point%20to%20Point%20Communication%20of%20LT-22222-L/]] page. The firmware that supports point-to-point communication can be found [[here>>https://github.com/dragino/LT-22222-L/releases]]. 2711 - 2712 2712 2713 2713 ))) 2714 2714 2715 2715 ((( 2716 -== 6. 7Why does the relay output default to an open relay after the LT-22222-L is powered off? ==2711 +== 6.6 Why does the relay output default to an open relay after the LT-22222-LA is powered off? == 2717 2717 2718 2718 2719 2719 * If the device is not properly shut down and is directly powered off. ... ... @@ -2721,23 +2721,19 @@ 2721 2721 * In modes 2 to 5, the DO/RO status and pulse count are saved to flash memory. 2722 2722 * After a restart, the status before the power failure will be read from Flash. 2723 2723 2724 -== 6. 8Can I set up LT-22222-L as an NC (Normally Closed) relay? ==2719 +== 6.7 Can I set up LT-22222-LA as an NC (Normally Closed) relay? == 2725 2725 2726 2726 2727 -The LT-22222-L's built-in relay is Normally Open (NO). You can use an external relay to achieve a Normally Closed (NC) configuration. The circuit diagram is shown below: 2722 +The LT-22222-LA's built-in relay is Normally Open (NO). You can use an external relay to achieve a Normally Closed (NC) configuration. The circuit diagram is shown below: 2728 2728 2724 +[[image:image-20221006170630-1.png]] 2729 2729 2730 2730 2731 2731 2732 -== 6.9 Can the LT-22222-L save the RO state? == 2733 2733 2729 +== 6.9 Why does the LT-22222-LA always report 15.585V when measuring the AVI? == 2734 2734 2735 -To enable this feature, the firmware version must be 1.6.0 or higher. 2736 2736 2737 - 2738 -== 6.10 Why does the LT-22222-L always report 15.585V when measuring the AVI? == 2739 - 2740 - 2741 2741 It is likely that the GND is not connected during the measurement, or that the wire connected to the GND is loose. 2742 2742 2743 2743