Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,7 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 +**LT-22222-L LoRa IO Controller User Manual ** 4 4 5 5 6 6 **Table of Contents:** ... ... @@ -166,6 +166,7 @@ 166 166 Packet engine up to 256 bytes with CRC. 167 167 168 168 170 + 169 169 170 170 ))) 171 171 ... ... @@ -179,6 +179,7 @@ 179 179 * Firmware upgradable via program port 180 180 * Counting 181 181 184 + 182 182 == 1.4 Applications == 183 183 184 184 * Smart Buildings & Home Automation ... ... @@ -188,6 +188,7 @@ 188 188 * Smart Cities 189 189 * Smart Factory 190 190 194 + 191 191 == 1.5 Hardware Variants == 192 192 193 193 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -218,11 +218,11 @@ 218 218 == 3.1 How it works? == 219 219 220 220 ((( 221 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%)will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network.(% style="color:green" %)**TX LED**(%%)will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second.225 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second. 222 222 ))) 223 223 224 224 ((( 225 -In case user can 't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.229 +In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 226 226 ))) 227 227 228 228 ... ... @@ -274,13 +274,15 @@ 274 274 275 275 There are five working modes + one interrupt mode on LT for different type application: 276 276 277 -* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO278 -* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO279 -* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO280 -* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO281 -* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO282 -* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5281 +* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 282 +* **MOD2**: Double DI Counting + DO + RO 283 +* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 284 +* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 285 +* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 +* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 283 283 288 + 289 + 284 284 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 285 285 286 286 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -334,6 +334,8 @@ 334 334 ** DO1 is high in case there is load between DO1 and V+. 335 335 ** DO1 LED is off in both case 336 336 343 + 344 + 337 337 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 338 338 339 339 ... ... @@ -407,8 +407,6 @@ 407 407 [[image:image-20220523181246-5.png]] 408 408 409 409 ((( 410 - 411 - 412 412 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 413 413 ))) 414 414 ... ... @@ -422,7 +422,6 @@ 422 422 (% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 423 423 ))) 424 424 425 - 426 426 ((( 427 427 **To use counting mode, please run:** 428 428 ))) ... ... @@ -555,8 +555,8 @@ 555 555 556 556 For example, if user has configured below commands: 557 557 558 -* **AT+MOD=1 ** 559 -* **AT+ADDMOD6=1** **~-~->** 563 +* **AT+MOD=1 ** **~-~->** The normal working mode 564 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 560 560 561 561 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 562 562 ... ... @@ -565,7 +565,6 @@ 565 565 566 566 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 567 567 568 - 569 569 (% style="color:#4f81bd" %)**Trigger base on voltage**: 570 570 571 571 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -705,6 +705,8 @@ 705 705 706 706 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 707 707 712 + 713 + 708 708 === 3.4.1 Common Commands === 709 709 710 710 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -713,7 +713,6 @@ 713 713 714 714 === 3.4.2 Sensor related commands === 715 715 716 - 717 717 ==== 3.4.2.1 Set Transmit Interval ==== 718 718 719 719 Set device uplink interval. ... ... @@ -767,7 +767,6 @@ 767 767 768 768 769 769 770 - 771 771 ==== 3.4.2.4 Enable Trigger Mode ==== 772 772 773 773 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -924,7 +924,6 @@ 924 924 925 925 926 926 927 - 928 928 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 929 929 930 930 * (% style="color:#037691" %)**AT Command** ... ... @@ -1076,7 +1076,7 @@ 1076 1076 1077 1077 (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1078 1078 1079 -[[image:image-20220 714135731-1.png||height="406" width="627"]]1082 +[[image:image-20220524093831-10.png]] 1080 1080 1081 1081 1082 1082 (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms ... ... @@ -1086,21 +1086,21 @@ 1086 1086 1087 1087 **Example payload:** 1088 1088 1089 -**~1. 05 01 11 07 D** 1092 +**~1. 05 01 11 07 D0** 1090 1090 1091 -Relay1 and Relay 2 will be set to N C, last 2 seconds, then change back to original state.1094 +Relay1 and Relay 2 will be set to NO , last 2 seconds, then change back to original state. 1092 1092 1093 1093 **2. 05 01 10 07 D0** 1094 1094 1095 -Relay1 will change to N C, Relay2 will change to NO, last 2 seconds, then both change back to original state.1098 +Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then both change back to original state. 1096 1096 1097 1097 **3. 05 00 01 07 D0** 1098 1098 1099 -Relay1 will change to N O, Relay2 will change to NC, last 2 seconds, then relay change to NC,Relay2 change to NO.1102 +Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then relay change to NO, Relay2 change to NC. 1100 1100 1101 1101 **4. 05 00 00 07 D0** 1102 1102 1103 -Relay 1 & relay2 will change to N O, last 2 seconds, then both change to NC.1106 +Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO. 1104 1104 1105 1105 1106 1106 ... ... @@ -1767,7 +1767,7 @@ 1767 1767 1768 1768 1769 1769 (% style="color:blue" %)**For LT-22222-L**(%%): 1770 -Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%)will change from OFF to ON. When(% style="color:red" %)**DO1 LED**(%%)is on, it means the device is in download mode.1773 +Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 1771 1771 ))) 1772 1772 1773 1773 [[image:image-20220524103407-12.png]] ... ... @@ -1882,7 +1882,7 @@ 1882 1882 1883 1883 ((( 1884 1884 ((( 1885 -== 6.1 Downlink doesn 't work, how to solve it? ==1888 +== 6.1 Downlink doesn’t work, how to solve it? == 1886 1886 ))) 1887 1887 ))) 1888 1888 ... ... @@ -1903,7 +1903,7 @@ 1903 1903 ((( 1904 1904 1905 1905 1906 -== 6.3 Why I can 't join TTN in US915 /AU915 bands? ==1909 +== 6.3 Why I can’t join TTN in US915 /AU915 bands? == 1907 1907 ))) 1908 1908 1909 1909 ((( ... ... @@ -1913,24 +1913,21 @@ 1913 1913 1914 1914 = 7. Order Info = 1915 1915 1916 - 1917 1917 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1918 1918 1921 + 1919 1919 (% style="color:#4f81bd" %)**XXX:** 1920 1920 1921 -* (% style="color: red" %)**EU433**(%%):1922 -* (% style="color: red" %)**EU868**(%%):1923 -* (% style="color: red" %)**KR920**(%%):1924 -* (% style="color: red" %)**CN470**(%%):1925 -* (% style="color: red" %)**AS923**(%%):1926 -* (% style="color: red" %)**AU915**(%%):1927 -* (% style="color: red" %)**US915**(%%):1928 -* (% style="color: red" %)**IN865**(%%):1929 -* (% style="color: red" %)**CN779**(%%):1924 +* (% style="color:#4f81bd" %)**EU433**(%%): LT with frequency bands EU433 1925 +* (% style="color:#4f81bd" %)**EU868**(%%): LT with frequency bands EU868 1926 +* (% style="color:#4f81bd" %)**KR920**(%%): LT with frequency bands KR920 1927 +* (% style="color:#4f81bd" %)**CN470**(%%): LT with frequency bands CN470 1928 +* (% style="color:#4f81bd" %)**AS923**(%%): LT with frequency bands AS923 1929 +* (% style="color:#4f81bd" %)**AU915**(%%): LT with frequency bands AU915 1930 +* (% style="color:#4f81bd" %)**US915**(%%): LT with frequency bands US915 1931 +* (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865 1932 +* (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779 1930 1930 1931 - 1932 - 1933 - 1934 1934 = 8. Packing Info = 1935 1935 1936 1936 ... ... @@ -1948,9 +1948,6 @@ 1948 1948 * Package Size / pcs : 14.5 x 8 x 5 cm 1949 1949 * Weight / pcs : 170g 1950 1950 1951 - 1952 - 1953 - 1954 1954 = 9. Support = 1955 1955 1956 1956 * ((( ... ... @@ -1958,10 +1958,12 @@ 1958 1958 ))) 1959 1959 * ((( 1960 1960 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1961 -))) 1962 1962 1963 1963 1964 1964 1961 + 1962 +))) 1963 + 1965 1965 = 10. Reference = 1966 1966 1967 1967 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
- image-20220714135731-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -54.1 KB - Content
- image-20220719105525-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -165.5 KB - Content
- image-20220719110247-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -52.9 KB - Content