Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,7 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 +**LT-22222-L LoRa IO Controller User Manual ** 4 4 5 5 6 6 **Table of Contents:** ... ... @@ -166,6 +166,7 @@ 166 166 Packet engine up to 256 bytes with CRC. 167 167 168 168 170 + 169 169 170 170 ))) 171 171 ... ... @@ -179,6 +179,9 @@ 179 179 * Firmware upgradable via program port 180 180 * Counting 181 181 184 + 185 + 186 + 182 182 == 1.4 Applications == 183 183 184 184 * Smart Buildings & Home Automation ... ... @@ -188,6 +188,9 @@ 188 188 * Smart Cities 189 189 * Smart Factory 190 190 196 + 197 + 198 + 191 191 == 1.5 Hardware Variants == 192 192 193 193 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -201,6 +201,8 @@ 201 201 * 1 x Counting Port 202 202 ))) 203 203 212 + 213 + 204 204 = 2. Power ON Device = 205 205 206 206 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -218,11 +218,11 @@ 218 218 == 3.1 How it works? == 219 219 220 220 ((( 221 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%)will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network.(% style="color:green" %)**TX LED**(%%)will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second.231 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second. 222 222 ))) 223 223 224 224 ((( 225 -In case user can 't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.235 +In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 226 226 ))) 227 227 228 228 ... ... @@ -274,15 +274,16 @@ 274 274 275 275 There are five working modes + one interrupt mode on LT for different type application: 276 276 277 -* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO278 -* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO279 -* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO280 -* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO281 -* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO282 -* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5287 +* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 288 +* **MOD2**: Double DI Counting + DO + RO 289 +* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 290 +* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 291 +* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 292 +* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 283 283 284 284 285 285 296 + 286 286 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 287 287 288 288 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -321,8 +321,6 @@ 321 321 * [1] RO1 relay channel is close and the RO1 LED is ON. 322 322 * [0] RO2 relay channel is open and RO2 LED is OFF; 323 323 324 - 325 - 326 326 **LT22222-L:** 327 327 328 328 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -338,8 +338,6 @@ 338 338 ** DO1 is high in case there is load between DO1 and V+. 339 339 ** DO1 LED is off in both case 340 340 341 - 342 - 343 343 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 344 344 345 345 ... ... @@ -376,7 +376,12 @@ 376 376 ((( 377 377 ((( 378 378 **AT+MOD=2** 386 +))) 387 +))) 379 379 389 +(% class="box infomessage" %) 390 +((( 391 +((( 380 380 **ATZ** 381 381 ))) 382 382 ))) ... ... @@ -389,20 +389,49 @@ 389 389 390 390 ((( 391 391 **For LT22222-L:** 404 +))) 392 392 406 +(% class="box infomessage" %) 407 +((( 408 +((( 409 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 410 +))) 411 +))) 393 393 394 -(% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger on low level, valid signal is 100ms) ** 413 +(% class="box infomessage" %) 414 +((( 415 +((( 416 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 417 +))) 418 +))) 395 395 396 -(% style="color:blue" %)**AT+TRIG1=1,100**(%%)** (set DI1 port to trigger on high level, valid signal is 100ms ) ** 420 +(% class="box infomessage" %) 421 +((( 422 +((( 423 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 424 +))) 425 +))) 397 397 398 -(% style="color:blue" %)**AT+TRIG2=0,100**(%%)** (set DI2 port to trigger on low level, valid signal is 100ms) ** 427 +(% class="box infomessage" %) 428 +((( 429 +((( 430 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 431 +))) 432 +))) 399 399 400 -(% style="color:blue" %)**AT+TRIG2=1,100**(%%)** (set DI2 port to trigger on high level, valid signal is 100ms ) ** 434 +(% class="box infomessage" %) 435 +((( 436 +((( 437 +**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 438 +))) 439 +))) 401 401 402 -(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 403 - 404 -(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 441 +(% class="box infomessage" %) 442 +((( 443 +((( 444 +**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 405 405 ))) 446 +))) 406 406 407 407 408 408 ... ... @@ -413,8 +413,6 @@ 413 413 [[image:image-20220523181246-5.png]] 414 414 415 415 ((( 416 - 417 - 418 418 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 419 419 ))) 420 420 ... ... @@ -428,7 +428,6 @@ 428 428 (% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 429 429 ))) 430 430 431 - 432 432 ((( 433 433 **To use counting mode, please run:** 434 434 ))) ... ... @@ -437,7 +437,12 @@ 437 437 ((( 438 438 ((( 439 439 **AT+MOD=3** 478 +))) 479 +))) 440 440 481 +(% class="box infomessage" %) 482 +((( 483 +((( 441 441 **ATZ** 442 442 ))) 443 443 ))) ... ... @@ -482,13 +482,20 @@ 482 482 ((( 483 483 ((( 484 484 **AT+MOD=4** 528 +))) 529 +))) 485 485 531 +(% class="box infomessage" %) 532 +((( 533 +((( 486 486 **ATZ** 487 487 ))) 488 488 ))) 489 489 538 +((( 539 + 540 +))) 490 490 491 - 492 492 ((( 493 493 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 494 494 ))) ... ... @@ -497,16 +497,35 @@ 497 497 498 498 499 499 **Plus below command for AVI1 Counting:** 550 +))) 500 500 552 +(% class="box infomessage" %) 553 +((( 554 +((( 555 +**AT+SETCNT=3,60 (set AVI Count to 60)** 556 +))) 557 +))) 501 501 502 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 559 +(% class="box infomessage" %) 560 +((( 561 +((( 562 +**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 563 +))) 564 +))) 503 503 504 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 566 +(% class="box infomessage" %) 567 +((( 568 +((( 569 +**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 570 +))) 571 +))) 505 505 506 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 507 - 508 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 573 +(% class="box infomessage" %) 574 +((( 575 +((( 576 +**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 509 509 ))) 578 +))) 510 510 511 511 512 512 ... ... @@ -543,7 +543,12 @@ 543 543 ((( 544 544 ((( 545 545 **AT+MOD=5** 615 +))) 616 +))) 546 546 618 +(% class="box infomessage" %) 619 +((( 620 +((( 547 547 **ATZ** 548 548 ))) 549 549 ))) ... ... @@ -561,8 +561,8 @@ 561 561 562 562 For example, if user has configured below commands: 563 563 564 -* **AT+MOD=1 ** 565 -* **AT+ADDMOD6=1** **~-~->** 638 +* **AT+MOD=1 ** **~-~->** The normal working mode 639 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 566 566 567 567 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 568 568 ... ... @@ -569,10 +569,8 @@ 569 569 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 570 570 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 571 571 646 +**AT Command to set Trigger Condition**: 572 572 573 -(% style="color:#037691" %)**AT Command to set Trigger Condition**: 574 - 575 - 576 576 (% style="color:#4f81bd" %)**Trigger base on voltage**: 577 577 578 578 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -607,7 +607,7 @@ 607 607 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 608 608 609 609 610 - (% style="color:#037691" %)**Downlink Command to set Trigger Condition:**682 +**Downlink Command to set Trigger Condition:** 611 611 612 612 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 613 613 ... ... @@ -712,8 +712,6 @@ 712 712 713 713 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 714 714 715 - 716 - 717 717 === 3.4.1 Common Commands === 718 718 719 719 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -726,50 +726,61 @@ 726 726 727 727 Set device uplink interval. 728 728 729 -* (% style="color:#037691" %)**AT Command:**799 +* AT Command: 730 730 801 +(% class="box infomessage" %) 802 +((( 731 731 **AT+TDC=N ** 804 +))) 732 732 733 - 734 734 **Example: **AT+TDC=30000. Means set interval to 30 seconds 735 735 736 736 737 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):**809 +* Downlink Payload (prefix 0x01): 738 738 811 +(% class="box infomessage" %) 812 +((( 739 739 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 814 +))) 740 740 741 741 742 742 743 - 744 744 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 745 745 746 746 Set work mode. 747 747 748 -* (% style="color:#037691" %)**AT Command:**822 +* AT Command: 749 749 824 +(% class="box infomessage" %) 825 +((( 750 750 **AT+MOD=N ** 827 +))) 751 751 752 - 753 753 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 754 754 755 755 756 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):**832 +* Downlink Payload (prefix 0x0A): 757 757 758 -**0x0A aa ** ~/~/ Same as AT+MOD=aa 834 +(% class="box infomessage" %) 835 +((( 836 +**0x0A aa ~/~/ Same as AT+MOD=aa** 837 +))) 759 759 760 760 761 761 762 - 763 763 ==== 3.4.2.3 Poll an uplink ==== 764 764 765 -* (% style="color:#037691" %)**AT Command:**843 +* AT Command: 766 766 767 767 There is no AT Command to poll uplink 768 768 769 769 770 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):**848 +* Downlink Payload (prefix 0x08): 771 771 772 -**0x08 FF **~/~/ Poll an uplink 850 +(% class="box infomessage" %) 851 +((( 852 +**0x08 FF ~/~/ Poll an uplink,** 853 +))) 773 773 774 774 **Example**: 0x08FF, ask device to send an Uplink 775 775 ... ... @@ -779,9 +779,12 @@ 779 779 780 780 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 781 781 782 -* (% style="color:#037691" %)**AT Command:**863 +* AT Command: 783 783 865 +(% class="box infomessage" %) 866 +((( 784 784 **AT+ADDMOD6=1 or 0** 868 +))) 785 785 786 786 1: Enable Trigger Mode 787 787 ... ... @@ -788,36 +788,43 @@ 788 788 0: Disable Trigger Mode 789 789 790 790 791 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):**875 +* Downlink Payload (prefix 0x0A 06): 792 792 793 -**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 877 +(% class="box infomessage" %) 878 +((( 879 +**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 880 +))) 794 794 795 795 796 796 797 - 798 798 ==== 3.4.2.5 Poll trigger settings ==== 799 799 800 800 Poll trigger settings, 801 801 802 -* (% style="color:#037691" %)**AT Command:**888 +* AT Command: 803 803 804 804 There is no AT Command for this feature. 805 805 806 806 807 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):**893 +* Downlink Payload (prefix 0x AB 06): 808 808 809 -**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 895 +(% class="box infomessage" %) 896 +((( 897 +**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 898 +))) 810 810 811 811 812 812 813 - 814 814 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 815 815 816 816 Enable Disable DI1/DI2/DI2 as trigger, 817 817 818 -* (% style="color:#037691" %)**AT Command:**906 +* AT Command: 819 819 908 +(% class="box infomessage" %) 909 +((( 820 820 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 911 +))) 821 821 822 822 823 823 **Example:** ... ... @@ -824,20 +824,25 @@ 824 824 825 825 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 826 826 827 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):**918 +* Downlink Payload (prefix 0xAA 02): 828 828 829 -**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 920 +(% class="box infomessage" %) 921 +((( 922 +**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 923 +))) 830 830 831 831 832 832 833 - 834 834 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 835 835 836 836 Set DI1 or DI3(for LT-33222-L) trigger. 837 837 838 -* (% style="color:#037691" %)**AT Command:**931 +* AT Command: 839 839 933 +(% class="box infomessage" %) 934 +((( 840 840 **AT+TRIG1=a,b** 936 +))) 841 841 842 842 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 843 843 ... ... @@ -849,18 +849,26 @@ 849 849 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 850 850 851 851 852 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 853 -* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 948 +* Downlink Payload (prefix 0x09 01 ): 854 854 950 +(% class="box infomessage" %) 951 +((( 952 +**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 953 +))) 954 + 955 + 956 + 855 855 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 856 856 857 857 Set DI2 trigger. 858 858 859 -* (% style="color:#037691" %)**AT Command:**961 +* AT Command: 860 860 963 +(% class="box infomessage" %) 964 +((( 861 861 **AT+TRIG2=a,b** 966 +))) 862 862 863 - 864 864 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 865 865 866 866 b : delay timing. ... ... @@ -871,62 +871,74 @@ 871 871 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 872 872 873 873 874 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):**978 +* Downlink Payload (prefix 0x09 02 ): 875 875 876 -**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 980 +(% class="box infomessage" %) 981 +((( 982 +**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 983 +))) 877 877 878 878 879 879 880 - 881 881 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 882 882 883 883 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 884 884 885 -* (% style="color:#037691" %)**AT Command**991 +* AT Command: 886 886 887 -**AT+ACLIM** 993 +(% class="box infomessage" %) 994 +((( 995 +**AT+ACLIM. ** 996 +))) 888 888 889 889 890 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )**999 +* Downlink Payload (prefix 0xAA 01 ): 891 891 892 -**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1001 +(% class="box infomessage" %) 1002 +((( 1003 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 1004 +))) 893 893 894 894 895 895 896 - 897 897 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 898 898 899 899 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 900 900 901 -* (% style="color:#037691" %)**AT Command**1012 +* AT Command: 902 902 903 -**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 1014 +(% class="box infomessage" %) 1015 +((( 1016 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 1017 +))) 904 904 905 905 906 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )**1020 +* Downlink Payload (prefix 0xAA 00 ): 907 907 908 -**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1022 +(% class="box infomessage" %) 1023 +((( 1024 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 1025 +))) 909 909 910 910 911 911 912 - 913 913 ==== 3.4.2.11 Trigger – Set minimum interval ==== 914 914 915 -Set AV and AC trigger minimum interval, system won 't response to the second trigger within this set time after the first trigger.1031 +Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 916 916 917 -* (% style="color:#037691" %)**AT Command**1033 +* AT Command: 918 918 919 -**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 1035 +(% class="box infomessage" %) 1036 +((( 1037 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 1038 +))) 920 920 921 921 922 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**1041 +* Downlink Payload (prefix 0xAC ): 923 923 924 -**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 925 - 1043 +(% class="box infomessage" %) 926 926 ((( 927 - 928 - 929 -(% style="color:red" %)Note: ATDC setting must be more than 5min 1045 +**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 930 930 ))) 931 931 932 932 ... ... @@ -933,15 +933,19 @@ 933 933 934 934 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 935 935 936 -* (% style="color:#037691" %)**AT Command**1052 +* AT Command: 937 937 938 938 There is no AT Command to control Digital Output 939 939 940 940 941 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 942 -* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 1057 +* Downlink Payload (prefix 0x02): 943 943 1059 +(% class="box infomessage" %) 944 944 ((( 1061 +**0x02 aa bb cc ~/~/ Set DO1/DO2/DO3 output** 1062 +))) 1063 + 1064 +((( 945 945 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 946 946 ))) 947 947 ... ... @@ -961,19 +961,22 @@ 961 961 962 962 963 963 964 - 965 965 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 966 966 967 -* (% style="color:#037691" %)**AT Command**1086 +* AT Command: 968 968 969 969 There is no AT Command to control Digital Output 970 970 971 971 972 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)**1091 +* Downlink Payload (prefix 0xA9): 973 973 974 -**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1093 +(% class="box infomessage" %) 1094 +((( 1095 +((( 1096 +**0xA9 aa bb cc ~/~/ Set DO1/DO2/DO3 output with time control** 1097 +))) 1098 +))) 975 975 976 - 977 977 This is to control the digital output time of DO pin. Include four bytes: 978 978 979 979 (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9) ... ... @@ -1027,19 +1027,20 @@ 1027 1027 1028 1028 1029 1029 1030 - 1031 1031 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1032 1032 1033 -* (% style="color:#037691" %)**AT Command:**1155 +* AT Command: 1034 1034 1035 1035 There is no AT Command to control Relay Output 1036 1036 1037 1037 1038 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x03):**1160 +* Downlink Payload (prefix 0x03): 1039 1039 1040 -**0x03 aa bb **~/~/ Set RO1/RO2 output 1162 +(% class="box infomessage" %) 1163 +((( 1164 +**0x03 aa bb ~/~/ Set RO1/RO2 output** 1165 +))) 1041 1041 1042 - 1043 1043 ((( 1044 1044 If payload = 0x030100, it means set RO1 to close and RO2 to open. 1045 1045 ))) ... ... @@ -1056,19 +1056,20 @@ 1056 1056 1057 1057 1058 1058 1059 - 1060 1060 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1061 1061 1062 -* (% style="color:#037691" %)**AT Command:**1185 +* AT Command: 1063 1063 1064 1064 There is no AT Command to control Relay Output 1065 1065 1066 1066 1067 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):**1190 +* Downlink Payload (prefix 0x05): 1068 1068 1069 -**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1192 +(% class="box infomessage" %) 1193 +((( 1194 +**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1195 +))) 1070 1070 1071 - 1072 1072 This is to control the relay output time of relay. Include four bytes: 1073 1073 1074 1074 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1110,28 +1110,35 @@ 1110 1110 1111 1111 1112 1112 1113 - 1114 1114 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1115 1115 1116 1116 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1117 1117 1118 -* (% style="color:#037691" %)**AT Command:**1242 +* AT Command: 1119 1119 1120 -**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1244 +(% class="box infomessage" %) 1245 +((( 1246 +**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1247 +))) 1121 1121 1122 1122 1123 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):**1250 +* Downlink Payload (prefix 0xA5): 1124 1124 1125 -**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1252 +(% class="box infomessage" %) 1253 +((( 1254 +**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1255 +))) 1126 1126 1127 1127 1128 1128 1129 - 1130 1130 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1131 1131 1132 -* (% style="color:#037691" %)**AT Command:**1261 +* AT Command: 1133 1133 1263 +(% class="box infomessage" %) 1264 +((( 1134 1134 **AT+SETCNT=aa,(bb cc dd ee) ** 1266 +))) 1135 1135 1136 1136 aa: 1: Set count1, 1137 1137 ... ... @@ -1142,40 +1142,51 @@ 1142 1142 Bb cc dd ee: number to be set 1143 1143 1144 1144 1145 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):**1277 +* Downlink Payload (prefix 0xA8): 1146 1146 1147 -**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1279 +(% class="box infomessage" %) 1280 +((( 1281 +**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1282 +))) 1148 1148 1149 1149 1150 1150 1151 - 1152 1152 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1153 1153 1154 1154 Clear counting for counting mode 1155 1155 1156 -* (% style="color:#037691" %)**AT Command:**1290 +* AT Command: 1157 1157 1158 -**AT+CLRCOUNT ** ~/~/ clear all counting 1292 +(% class="box infomessage" %) 1293 +((( 1294 +**AT+CLRCOUNT ~/~/ clear all counting** 1295 +))) 1159 1159 1297 +* Downlink Payload (prefix 0xA6): 1160 1160 1161 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1299 +(% class="box infomessage" %) 1300 +((( 1301 +**0x A6 01 ~/~/ clear all counting,** 1302 +))) 1162 1162 1163 -**0x A6 01 ** ~/~/ clear all counting 1164 1164 1165 1165 1166 - 1167 - 1168 1168 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1169 1169 1170 -* (% style="color:#037691" %)**AT Command:**1308 +* AT Command: 1171 1171 1172 -**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1310 +(% class="box infomessage" %) 1311 +((( 1312 +**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1313 +))) 1173 1173 1315 +* Downlink Payload (prefix 0xA7): 1174 1174 1175 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1317 +(% class="box infomessage" %) 1318 +((( 1319 +**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1320 +))) 1176 1176 1177 -**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1178 - 1179 1179 ((( 1180 1180 range: aa bb cc:0 to 16777215, (unit:second) 1181 1181 ... ... @@ -1183,7 +1183,6 @@ 1183 1183 ))) 1184 1184 1185 1185 1186 - 1187 1187 == 3.5 Integrate with Mydevice == 1188 1188 1189 1189 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -1413,7 +1413,6 @@ 1413 1413 [[image:image-20220524100748-11.png]] 1414 1414 1415 1415 1416 - 1417 1417 = 4. Use AT Command = 1418 1418 1419 1419 == 4.1 Access AT Command == ... ... @@ -1616,6 +1616,8 @@ 1616 1616 1617 1617 ((( 1618 1618 AT+CFG: Print all settings 1760 + 1761 + 1619 1619 ))) 1620 1620 1621 1621 ... ... @@ -1661,6 +1661,8 @@ 1661 1661 1662 1662 ((( 1663 1663 (% style="background-color:#dcdcdc" %)ATZ 1807 + 1808 + 1664 1664 ))) 1665 1665 1666 1666 ... ... @@ -1867,8 +1867,6 @@ 1867 1867 == 5.5 Can i use point to point communication for LT-22222-L? == 1868 1868 1869 1869 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1870 - 1871 - 1872 1872 ))) 1873 1873 1874 1874 ((( ... ... @@ -1882,7 +1882,6 @@ 1882 1882 1883 1883 After restart, the status before power failure will be read from flash. 1884 1884 1885 - 1886 1886 = 6. Trouble Shooting = 1887 1887 ))) 1888 1888 ... ... @@ -1917,8 +1917,10 @@ 1917 1917 ))) 1918 1918 1919 1919 2062 + 1920 1920 = 7. Order Info = 1921 1921 2065 + 1922 1922 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1923 1923 1924 1924 ... ... @@ -1958,10 +1958,6 @@ 1958 1958 ))) 1959 1959 * ((( 1960 1960 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1961 - 1962 - 1963 - 1964 - 1965 1965 ))) 1966 1966 1967 1967 = 10. Reference =