<
From version < 80.2 >
edited by Xiaoling
on 2022/06/10 10:19
To version < 77.91 >
edited by Xiaoling
on 2022/06/10 09:29
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -48,7 +48,6 @@
48 48  
49 49  )))
50 50  
51 -
52 52  == 1.2  Specifications ==
53 53  
54 54  (((
... ... @@ -77,8 +77,6 @@
77 77  )))
78 78  
79 79  (((
80 -
81 -
82 82  **Interface for Model: LT22222-L:**
83 83  )))
84 84  
... ... @@ -102,8 +102,6 @@
102 102  )))
103 103  
104 104  (((
105 -
106 -
107 107  **LoRa Spec:**
108 108  )))
109 109  
... ... @@ -163,11 +163,10 @@
163 163  )))
164 164  * (((
165 165  Packet engine up to 256 bytes with CRC.
161 +
162 +
166 166  )))
167 167  
168 -
169 -
170 -
171 171  == 1.3 Features ==
172 172  
173 173  * LoRaWAN Class A & Class C protocol
... ... @@ -178,9 +178,6 @@
178 178  * Firmware upgradable via program port
179 179  * Counting
180 180  
181 -
182 -
183 -
184 184  == 1.4  Applications ==
185 185  
186 186  * Smart Buildings & Home Automation
... ... @@ -190,9 +190,6 @@
190 190  * Smart Cities
191 191  * Smart Factory
192 192  
193 -
194 -
195 -
196 196  == 1.5 Hardware Variants ==
197 197  
198 198  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -206,9 +206,6 @@
206 206  * 1 x Counting Port
207 207  )))
208 208  
209 -
210 -
211 -
212 212  = 2. Power ON Device =
213 213  
214 214  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -231,9 +231,12 @@
231 231  
232 232  (((
233 233  In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
219 +
220 +
234 234  )))
235 235  
236 236  
224 +
237 237  == 3.2 Example to join LoRaWAN network ==
238 238  
239 239  (((
... ... @@ -242,13 +242,12 @@
242 242  
243 243  [[image:image-20220523172350-1.png||height="266" width="864"]]
244 244  
245 -
246 246  (((
247 247  The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN:
248 248  )))
249 249  
250 250  (((
251 -(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.
238 +**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller.
252 252  )))
253 253  
254 254  (((
... ... @@ -257,7 +257,6 @@
257 257  
258 258  [[image:1653297924498-393.png]]
259 259  
260 -
261 261  Input these keys in the LoRaWAN Server portal. Below is TTN screen shot:
262 262  
263 263  Add APP EUI in the application.
... ... @@ -271,7 +271,7 @@
271 271  
272 272  
273 273  (((
274 -(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
260 +**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
275 275  )))
276 276  
277 277  [[image:1653298044601-602.png||height="405" width="709"]]
... ... @@ -289,6 +289,8 @@
289 289  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
290 290  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
291 291  
278 +
279 +
292 292  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
293 293  
294 294  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -327,6 +327,7 @@
327 327  * [1] RO1 relay channel is close and the RO1 LED is ON.
328 328  * [0] RO2 relay channel is open and RO2 LED is OFF;
329 329  
318 +
330 330  **LT22222-L:**
331 331  
332 332  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -342,6 +342,8 @@
342 342  ** DO1 is high in case there is load between DO1 and V+.
343 343  ** DO1 LED is off in both case
344 344  
334 +
335 +
345 345  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
346 346  
347 347  
... ... @@ -482,10 +482,11 @@
482 482  
483 483  (((
484 484  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
476 +
477 +
485 485  )))
486 486  
487 487  
488 -
489 489  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
490 490  
491 491  
... ... @@ -651,7 +651,6 @@
651 651  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
652 652  
653 653  
654 -
655 655  (% style="color:#4f81bd" %)**Trigger base on current**:
656 656  
657 657  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -661,7 +661,6 @@
661 661  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
662 662  
663 663  
664 -
665 665  (% style="color:#4f81bd" %)**Trigger base on DI status**:
666 666  
667 667  DI status trigger Flag.
... ... @@ -668,13 +668,12 @@
668 668  
669 669  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
670 670  
671 -
672 672  **Example:**
673 673  
674 674  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
675 675  
676 676  
677 -**Downlink Command to set Trigger Condition:**
666 +**Downlink Command to set Trigger Condition**
678 678  
679 679  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
680 680  
... ... @@ -703,7 +703,6 @@
703 703  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
704 704  
705 705  
706 -
707 707  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
708 708  
709 709  MOD6 Payload : total 11 bytes payload
... ... @@ -767,6 +767,7 @@
767 767  )))
768 768  
769 769  
758 +
770 770  == 3.4 ​Configure LT via AT or Downlink ==
771 771  
772 772  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
... ... @@ -780,6 +780,8 @@
780 780  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
781 781  
782 782  
772 +
773 +
783 783  === 3.4.1 Common Commands ===
784 784  
785 785  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0