... ... @@ -314,6 +314,8 @@
314 314  * [1] RO1 relay channel is close and the RO1 LED is ON.
315 315  * [0] RO2 relay channel is open and RO2 LED is OFF;
316 316  
317 +
318 +
317 317  **LT22222-L:**
318 318  
319 319  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -330,6 +330,7 @@
330 330  ** DO1 LED is off in both case
331 331  
332 332  
335 +
333 333  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
334 334  
335 335  
... ... @@ -622,11 +622,14 @@
622 622  * **AT+MOD=1 ** **~-~->** The normal working mode
623 623  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
624 624  
628 +
625 625  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
626 626  
627 627  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
628 628  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
629 629  
634 +
635 +
630 630  **AT Command to set Trigger Condition**:
631 631  
632 632  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -640,6 +640,7 @@
640 640  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
641 641  
642 642  
649 +
643 643  (% style="color:#4f81bd" %)**Trigger base on current**:
644 644  
645 645  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -649,6 +649,7 @@
649 649  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
650 650  
651 651  
659 +
652 652  (% style="color:#4f81bd" %)**Trigger base on DI status**:
653 653  
654 654  DI status trigger Flag.