Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -235,7 +235,7 @@ 235 235 ))) 236 236 237 237 ((( 238 -**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller. 238 +**(% style="color:blue" %)Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller. 239 239 ))) 240 240 241 241 ((( ... ... @@ -257,7 +257,7 @@ 257 257 258 258 259 259 ((( 260 -**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 260 +**(% style="color:blue" %)Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 261 261 ))) 262 262 263 263 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -275,6 +275,8 @@ 275 275 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 278 + 279 + 278 278 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 279 279 280 280 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -282,6 +282,8 @@ 282 282 [[image:image-20220523174024-3.png]] 283 283 284 284 ((( 287 + 288 + 285 285 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 286 286 ))) 287 287 ... ... @@ -295,6 +295,7 @@ 295 295 296 296 For example if payload is: [[image:image-20220523175847-2.png]] 297 297 302 + 298 298 **The value for the interface is: ** 299 299 300 300 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V ... ... @@ -310,6 +310,8 @@ 310 310 * [1] RO1 relay channel is close and the RO1 LED is ON. 311 311 * [0] RO2 relay channel is open and RO2 LED is OFF; 312 312 318 + 319 + 313 313 **LT22222-L:** 314 314 315 315 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -325,8 +325,11 @@ 325 325 ** DO1 is high in case there is load between DO1 and V+. 326 326 ** DO1 LED is off in both case 327 327 335 + 336 + 328 328 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 329 329 339 + 330 330 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. 331 331 332 332 ((( ... ... @@ -335,6 +335,7 @@ 335 335 336 336 [[image:image-20220523180452-3.png]] 337 337 348 + 338 338 ((( 339 339 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 340 340 ))) ... ... @@ -350,6 +350,8 @@ 350 350 ))) 351 351 352 352 ((( 364 + 365 + 353 353 **To use counting mode, please run:** 354 354 ))) 355 355 ... ... @@ -368,6 +368,8 @@ 368 368 ))) 369 369 370 370 ((( 384 + 385 + 371 371 (% style="color:#4f81bd" %)**AT Commands for counting:** 372 372 ))) 373 373 ... ... @@ -464,9 +464,9 @@ 464 464 ))) 465 465 466 466 467 - 468 468 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 469 469 484 + 470 470 **LT22222-L**: This mode the DI1 is used as a counting pin. 471 471 472 472 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. ... ... @@ -473,6 +473,7 @@ 473 473 474 474 [[image:image-20220523181903-8.png]] 475 475 491 + 476 476 ((( 477 477 (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 478 478 ))) ... ... @@ -488,6 +488,8 @@ 488 488 ))) 489 489 490 490 ((( 507 + 508 + 491 491 **To use this mode, please run:** 492 492 ))) 493 493 ... ... @@ -514,6 +514,8 @@ 514 514 ))) 515 515 516 516 ((( 535 + 536 + 517 517 **Plus below command for AVI1 Counting:** 518 518 ))) 519 519 ... ... @@ -549,11 +549,14 @@ 549 549 550 550 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 551 551 572 + 552 552 **LT22222-L**: This mode the DI1 is used as a counting pin. 553 553 554 554 [[image:image-20220523182334-9.png]] 555 555 556 556 ((( 578 + 579 + 557 557 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 558 558 ))) 559 559 ... ... @@ -568,6 +568,8 @@ 568 568 ))) 569 569 570 570 ((( 594 + 595 + 571 571 **To use this mode, please run:** 572 572 ))) 573 573 ... ... @@ -587,8 +587,6 @@ 587 587 588 588 ((( 589 589 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 590 - 591 - 592 592 ))) 593 593 594 594 ... ... @@ -595,6 +595,7 @@ 595 595 596 596 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 597 597 621 + 598 598 (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** 599 599 600 600 For example, if user has configured below commands: ... ... @@ -602,11 +602,14 @@ 602 602 * **AT+MOD=1 ** **~-~->** The normal working mode 603 603 * **AT+ADDMOD6=1** **~-~->** Enable trigger 604 604 629 + 605 605 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 606 606 607 607 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 608 608 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 609 609 635 + 636 + 610 610 **AT Command to set Trigger Condition**: 611 611 612 612 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -620,6 +620,7 @@ 620 620 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 621 621 622 622 650 + 623 623 (% style="color:#4f81bd" %)**Trigger base on current**: 624 624 625 625 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -629,6 +629,7 @@ 629 629 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 630 630 631 631 660 + 632 632 (% style="color:#4f81bd" %)**Trigger base on DI status**: 633 633 634 634 DI status trigger Flag. ... ... @@ -635,12 +635,13 @@ 635 635 636 636 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 637 637 667 + 638 638 **Example:** 639 639 640 640 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 641 641 642 642 643 -**Downlink Command to set Trigger Condition** 673 +**Downlink Command to set Trigger Condition:** 644 644 645 645 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 646 646 ... ... @@ -658,14 +658,18 @@ 658 658 659 659 Yy4 yy4: AC2 or AV2 high limit. 660 660 691 + 661 661 **Example1**: AA 00 13 88 00 00 00 00 00 00 662 662 663 663 Same as AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 664 664 696 + 665 665 **Example2**: AA 02 01 00 666 666 667 667 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 668 668 701 + 702 + 669 669 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 670 670 671 671 MOD6 Payload : total 11 bytes payload ... ... @@ -672,6 +672,7 @@ 672 672 673 673 [[image:image-20220524085923-1.png]] 674 674 709 + 675 675 (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 676 676 677 677 [[image:image-20220524090106-2.png]] ... ... @@ -678,6 +678,8 @@ 678 678 679 679 * Each bits shows if the corresponding trigger has been configured. 680 680 716 + 717 + 681 681 **Example:** 682 682 683 683 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -689,6 +689,8 @@ 689 689 690 690 * Each bits shows which status has been trigger on this uplink. 691 691 729 + 730 + 692 692 **Example:** 693 693 694 694 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -700,6 +700,8 @@ 700 700 701 701 * Each bits shows which status has been trigger on this uplink. 702 702 742 + 743 + 703 703 **Example:** 704 704 705 705 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -720,6 +720,8 @@ 720 720 === 3.3.7 Payload Decoder === 721 721 722 722 ((( 764 + 765 + 723 723 **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 724 724 725 725