From version < 77.112 >
edited by Xiaoling
on 2022/06/10 09:37
To version < 77.94 >
edited by Xiaoling
on 2022/06/10 09:31
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -76,8 +76,6 @@
76 76  )))
77 77  
78 78  (((
79 -
80 -
81 81  **Interface for Model: LT22222-L:**
82 82  )))
83 83  
... ... @@ -101,8 +101,6 @@
101 101  )))
102 102  
103 103  (((
104 -
105 -
106 106  **LoRa Spec:**
107 107  )))
108 108  
... ... @@ -166,8 +166,6 @@
166 166  
167 167  )))
168 168  
169 -
170 -
171 171  == 1.3 Features ==
172 172  
173 173  * LoRaWAN Class A & Class C protocol
... ... @@ -178,8 +178,6 @@
178 178  * Firmware upgradable via program port
179 179  * Counting
180 180  
181 -
182 -
183 183  == 1.4  Applications ==
184 184  
185 185  * Smart Buildings & Home Automation
... ... @@ -189,8 +189,6 @@
189 189  * Smart Cities
190 190  * Smart Factory
191 191  
192 -
193 -
194 194  == 1.5 Hardware Variants ==
195 195  
196 196  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -204,7 +204,6 @@
204 204  * 1 x Counting Port
205 205  )))
206 206  
207 -
208 208  = 2. Power ON Device =
209 209  
210 210  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -227,9 +227,12 @@
227 227  
228 228  (((
229 229  In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
219 +
220 +
230 230  )))
231 231  
232 232  
224 +
233 233  == 3.2 Example to join LoRaWAN network ==
234 234  
235 235  (((
... ... @@ -238,13 +238,12 @@
238 238  
239 239  [[image:image-20220523172350-1.png||height="266" width="864"]]
240 240  
241 -
242 242  (((
243 243  The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN:
244 244  )))
245 245  
246 246  (((
247 -(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.
238 +**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller.
248 248  )))
249 249  
250 250  (((
... ... @@ -253,7 +253,6 @@
253 253  
254 254  [[image:1653297924498-393.png]]
255 255  
256 -
257 257  Input these keys in the LoRaWAN Server portal. Below is TTN screen shot:
258 258  
259 259  Add APP EUI in the application.
... ... @@ -267,7 +267,7 @@
267 267  
268 268  
269 269  (((
270 -(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
260 +**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
271 271  )))
272 272  
273 273  [[image:1653298044601-602.png||height="405" width="709"]]
... ... @@ -650,7 +650,6 @@
650 650  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
651 651  
652 652  
653 -
654 654  (% style="color:#4f81bd" %)**Trigger base on current**:
655 655  
656 656  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -660,7 +660,6 @@
660 660  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
661 661  
662 662  
663 -
664 664  (% style="color:#4f81bd" %)**Trigger base on DI status**:
665 665  
666 666  DI status trigger Flag.
... ... @@ -716,6 +716,8 @@
716 716  
717 717  * Each bits shows if the corresponding trigger has been configured.
718 718  
707 +
708 +
719 719  **Example:**
720 720  
721 721  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -727,6 +727,8 @@
727 727  
728 728  * Each bits shows which status has been trigger on this uplink.
729 729  
720 +
721 +
730 730  **Example:**
731 731  
732 732  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -738,6 +738,8 @@
738 738  
739 739  * Each bits shows which status has been trigger on this uplink.
740 740  
733 +
734 +
741 741  **Example:**
742 742  
743 743  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -779,6 +779,8 @@
779 779  
780 780  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
781 781  
776 +
777 +
782 782  === 3.4.1 Common Commands ===
783 783  
784 784  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0