... ... @@ -221,6 +221,7 @@
221 221  )))
222 222  
223 223  
224 +
224 224  == 3.2 Example to join LoRaWAN network ==
225 225  
226 226  (((
... ... @@ -229,13 +229,12 @@
229 229  
230 230  [[image:image-20220523172350-1.png||height="266" width="864"]]
231 231  
232 -
233 233  (((
234 234  The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN:
235 235  )))
236 236  
237 237  (((
238 -(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.
238 +**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller.
239 239  )))
240 240  
241 241  (((
... ... @@ -244,7 +244,6 @@
244 244  
245 245  [[image:1653297924498-393.png]]
246 246  
247 -
248 248  Input these keys in the LoRaWAN Server portal. Below is TTN screen shot:
249 249  
250 250  Add APP EUI in the application.
... ... @@ -258,7 +258,7 @@
258 258  
259 259  
260 260  (((
261 -(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
260 +**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
262 262  )))
263 263  
264 264  [[image:1653298044601-602.png||height="405" width="709"]]
... ... @@ -277,7 +277,6 @@
277 277  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
278 278  
279 279  
280 -
281 281  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
282 282  
283 283  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -316,7 +316,6 @@
316 316  * [1] RO1 relay channel is close and the RO1 LED is ON.
317 317  * [0] RO2 relay channel is open and RO2 LED is OFF;
318 318  
319 -
320 320  **LT22222-L:**
321 321  
322 322  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -333,7 +333,6 @@
333 333  ** DO1 LED is off in both case
334 334  
335 335  
336 -
337 337  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
338 338  
339 339  
... ... @@ -631,7 +631,6 @@
631 631  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
632 632  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
633 633  
634 -
635 635  **AT Command to set Trigger Condition**:
636 636  
637 637  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -645,7 +645,6 @@
645 645  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
646 646  
647 647  
648 -
649 649  (% style="color:#4f81bd" %)**Trigger base on current**:
650 650  
651 651  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -655,7 +655,6 @@
655 655  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
656 656  
657 657  
658 -
659 659  (% style="color:#4f81bd" %)**Trigger base on DI status**:
660 660  
661 661  DI status trigger Flag.
... ... @@ -668,7 +668,7 @@
668 668  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
669 669  
670 670  
671 -**Downlink Command to set Trigger Condition:**
664 +**Downlink Command to set Trigger Condition**
672 672  
673 673  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
674 674  
... ... @@ -692,12 +692,12 @@
692 692  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
693 693  
694 694  
688 +
695 695  **Example2**: AA 02 01 00
696 696  
697 697  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
698 698  
699 699  
700 -
701 701  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
702 702  
703 703  MOD6 Payload : total 11 bytes payload
... ... @@ -712,6 +712,7 @@
712 712  * Each bits shows if the corresponding trigger has been configured.
713 713  
714 714  
708 +
715 715  **Example:**
716 716  
717 717  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -724,6 +724,7 @@
724 724  * Each bits shows which status has been trigger on this uplink.
725 725  
726 726  
721 +
727 727  **Example:**
728 728  
729 729  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -736,6 +736,7 @@
736 736  * Each bits shows which status has been trigger on this uplink.
737 737  
738 738  
734 +
739 739  **Example:**
740 740  
741 741  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -778,6 +778,7 @@
778 778  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
779 779  
780 780  
777 +
781 781  === 3.4.1 Common Commands ===
782 782  
783 783  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]