... ... @@ -221,6 +221,7 @@
221 221  )))
222 222  
223 223  
224 +
224 224  == 3.2 Example to join LoRaWAN network ==
225 225  
226 226  (((
... ... @@ -229,13 +229,12 @@
229 229  
230 230  [[image:image-20220523172350-1.png||height="266" width="864"]]
231 231  
232 -
233 233  (((
234 234  The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN:
235 235  )))
236 236  
237 237  (((
238 -(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.
238 +**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller.
239 239  )))
240 240  
241 241  (((
... ... @@ -244,7 +244,6 @@
244 244  
245 245  [[image:1653297924498-393.png]]
246 246  
247 -
248 248  Input these keys in the LoRaWAN Server portal. Below is TTN screen shot:
249 249  
250 250  Add APP EUI in the application.
... ... @@ -258,7 +258,7 @@
258 258  
259 259  
260 260  (((
261 -(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
260 +**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
262 262  )))
263 263  
264 264  [[image:1653298044601-602.png||height="405" width="709"]]
... ... @@ -315,7 +315,6 @@
315 315  * [1] RO1 relay channel is close and the RO1 LED is ON.
316 316  * [0] RO2 relay channel is open and RO2 LED is OFF;
317 317  
318 -
319 319  **LT22222-L:**
320 320  
321 321  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -332,7 +332,6 @@
332 332  ** DO1 LED is off in both case
333 333  
334 334  
335 -
336 336  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
337 337  
338 338  
... ... @@ -630,7 +630,6 @@
630 630  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
631 631  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
632 632  
633 -
634 634  **AT Command to set Trigger Condition**:
635 635  
636 636  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -644,7 +644,6 @@
644 644  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
645 645  
646 646  
647 -
648 648  (% style="color:#4f81bd" %)**Trigger base on current**:
649 649  
650 650  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -654,7 +654,6 @@
654 654  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
655 655  
656 656  
657 -
658 658  (% style="color:#4f81bd" %)**Trigger base on DI status**:
659 659  
660 660  DI status trigger Flag.
... ... @@ -661,13 +661,12 @@
661 661  
662 662  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
663 663  
664 -
665 665  **Example:**
666 666  
667 667  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
668 668  
669 669  
670 -**Downlink Command to set Trigger Condition:**
663 +**Downlink Command to set Trigger Condition**
671 671  
672 672  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
673 673  
... ... @@ -696,7 +696,6 @@
696 696  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
697 697  
698 698  
699 -
700 700  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
701 701  
702 702  MOD6 Payload : total 11 bytes payload
... ... @@ -710,7 +710,6 @@
710 710  
711 711  * Each bits shows if the corresponding trigger has been configured.
712 712  
713 -
714 714  **Example:**
715 715  
716 716  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -723,6 +723,7 @@
723 723  * Each bits shows which status has been trigger on this uplink.
724 724  
725 725  
717 +
726 726  **Example:**
727 727  
728 728  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -735,6 +735,7 @@
735 735  * Each bits shows which status has been trigger on this uplink.
736 736  
737 737  
730 +
738 738  **Example:**
739 739  
740 740  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -777,6 +777,7 @@
777 777  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
778 778  
779 779  
773 +
780 780  === 3.4.1 Common Commands ===
781 781  
782 782  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]