Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -235,7 +235,7 @@ 235 235 ))) 236 236 237 237 ((( 238 - (% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.238 +**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller. 239 239 ))) 240 240 241 241 ((( ... ... @@ -244,7 +244,6 @@ 244 244 245 245 [[image:1653297924498-393.png]] 246 246 247 - 248 248 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 249 249 250 250 Add APP EUI in the application. ... ... @@ -258,7 +258,7 @@ 258 258 259 259 260 260 ((( 261 - (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.260 +**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 262 262 ))) 263 263 264 264 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -276,7 +276,6 @@ 276 276 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 277 277 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 278 278 279 - 280 280 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 281 281 282 282 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -284,8 +284,6 @@ 284 284 [[image:image-20220523174024-3.png]] 285 285 286 286 ((( 287 - 288 - 289 289 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 290 290 ))) 291 291 ... ... @@ -299,7 +299,6 @@ 299 299 300 300 For example if payload is: [[image:image-20220523175847-2.png]] 301 301 302 - 303 303 **The value for the interface is: ** 304 304 305 305 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V ... ... @@ -315,7 +315,6 @@ 315 315 * [1] RO1 relay channel is close and the RO1 LED is ON. 316 316 * [0] RO2 relay channel is open and RO2 LED is OFF; 317 317 318 - 319 319 **LT22222-L:** 320 320 321 321 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -331,10 +331,8 @@ 331 331 ** DO1 is high in case there is load between DO1 and V+. 332 332 ** DO1 LED is off in both case 333 333 334 - 335 335 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 336 336 337 - 338 338 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. 339 339 340 340 ((( ... ... @@ -343,7 +343,6 @@ 343 343 344 344 [[image:image-20220523180452-3.png]] 345 345 346 - 347 347 ((( 348 348 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 349 349 ))) ... ... @@ -359,8 +359,6 @@ 359 359 ))) 360 360 361 361 ((( 362 - 363 - 364 364 **To use counting mode, please run:** 365 365 ))) 366 366 ... ... @@ -379,8 +379,6 @@ 379 379 ))) 380 380 381 381 ((( 382 - 383 - 384 384 (% style="color:#4f81bd" %)**AT Commands for counting:** 385 385 ))) 386 386 ... ... @@ -477,9 +477,9 @@ 477 477 ))) 478 478 479 479 467 + 480 480 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 481 481 482 - 483 483 **LT22222-L**: This mode the DI1 is used as a counting pin. 484 484 485 485 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. ... ... @@ -486,7 +486,6 @@ 486 486 487 487 [[image:image-20220523181903-8.png]] 488 488 489 - 490 490 ((( 491 491 (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 492 492 ))) ... ... @@ -616,7 +616,6 @@ 616 616 617 617 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 618 618 619 - 620 620 (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** 621 621 622 622 For example, if user has configured below commands: ... ... @@ -624,6 +624,7 @@ 624 624 * **AT+MOD=1 ** **~-~->** The normal working mode 625 625 * **AT+ADDMOD6=1** **~-~->** Enable trigger 626 626 612 + 627 627 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 628 628 629 629 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type ... ... @@ -643,7 +643,6 @@ 643 643 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 644 644 645 645 646 - 647 647 (% style="color:#4f81bd" %)**Trigger base on current**: 648 648 649 649 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -653,7 +653,6 @@ 653 653 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 654 654 655 655 656 - 657 657 (% style="color:#4f81bd" %)**Trigger base on DI status**: 658 658 659 659 DI status trigger Flag. ... ... @@ -660,13 +660,12 @@ 660 660 661 661 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 662 662 663 - 664 664 **Example:** 665 665 666 666 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 667 667 668 668 669 -**Downlink Command to set Trigger Condition :**652 +**Downlink Command to set Trigger Condition** 670 670 671 671 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 672 672 ... ... @@ -695,7 +695,6 @@ 695 695 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 696 696 697 697 698 - 699 699 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 700 700 701 701 MOD6 Payload : total 11 bytes payload ... ... @@ -754,8 +754,6 @@ 754 754 === 3.3.7 Payload Decoder === 755 755 756 756 ((( 757 - 758 - 759 759 **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 760 760 761 761 ... ... @@ -776,6 +776,7 @@ 776 776 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 777 777 778 778 759 + 779 779 === 3.4.1 Common Commands === 780 780 781 781 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]