From version < 188.1 >
edited by Bei Jinggeng
on 2024/11/11 09:50
To version < 186.1 >
edited by Dilisi S
on 2024/11/11 02:43
>
Change comment: Nov 10 edits part 1

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -LT-22222-L -- LoRa I/O Controller User Manual
1 +LT-22222-L -- LoRa IO Controller User Manual
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.pradeeka
Content
... ... @@ -40,9 +40,7 @@
40 40  * If there is no public LoRaWAN coverage in your area, you can set up a LoRaWAN gateway, or multiple gateways, and connect them to a LoRaWAN network server to create adequate coverage. Then, register the LT-22222-L I/O controller with this network.
41 41  * Setup your own private LoRaWAN network.
42 42  
43 -{{info}}
44 - You can use a LoRaWAN gateway, such as the [[Dragino LG308>>https://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], to expand or create LoRaWAN coverage in your area.
45 -{{/info}}
43 +> You can use a LoRaWAN gateway, such as the Dragino LG308, to expand or create LoRaWAN coverage in your area.
46 46  )))
47 47  
48 48  (((
... ... @@ -58,13 +58,13 @@
58 58  * STM32L072xxxx MCU
59 59  * SX1276/78 Wireless Chip 
60 60  * Power Consumption:
61 -** Idle: 4mA@12V
59 +** Idle: 4mA@12v
62 62  ** 20dB Transmit: 34mA@12V
63 63  * Operating Temperature: -40 ~~ 85 Degrees, No Dew
64 64  
65 65  (% style="color:#037691" %)**Interface for Model: LT22222-L:**
66 66  
67 -* 2 x Digital dual direction Input (Detect High/Low signal, Max: 50V, or 220V with optional external resistor)
65 +* 2 x Digital dual direction Input (Detect High/Low signal, Max: 50v, or 220v with optional external resistor)
68 68  * 2 x Digital Output (NPN output. Max pull-up voltage 36V,450mA)
69 69  * 2 x Relay Output (5A@250VAC / 30VDC)
70 70  * 2 x 0~~20mA Analog Input (res:0.01mA)
... ... @@ -74,8 +74,8 @@
74 74  (% style="color:#037691" %)**LoRa Spec:**
75 75  
76 76  * Frequency Range:
77 -** Band 1 (HF): 862 ~~ 1020 MHz
78 -** Band 2 (LF): 410 ~~ 528 MHz
75 +** Band 1 (HF): 862 ~~ 1020 Mhz
76 +** Band 2 (LF): 410 ~~ 528 Mhz
79 79  * 168 dB maximum link budget.
80 80  * +20 dBm - 100 mW constant RF output vs.
81 81  * +14 dBm high-efficiency PA.
... ... @@ -94,7 +94,7 @@
94 94  
95 95  == 1.3 Features ==
96 96  
97 -* LoRaWAN Class A & Class C modes
95 +* LoRaWAN Class A & Class C protocol
98 98  * Optional Customized LoRa Protocol
99 99  * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869
100 100  * AT Commands to change parameters
... ... @@ -104,12 +104,12 @@
104 104  
105 105  == 1.4 Applications ==
106 106  
107 -* Smart buildings & home automation
108 -* Logistics and supply chain management
109 -* Smart metering
110 -* Smart agriculture
111 -* Smart cities
112 -* Smart factory
105 +* Smart Buildings & Home Automation
106 +* Logistics and Supply Chain Management
107 +* Smart Metering
108 +* Smart Agriculture
109 +* Smart Cities
110 +* Smart Factory
113 113  
114 114  == 1.5 Hardware Variants ==
115 115  
... ... @@ -128,16 +128,10 @@
128 128  * 1 x Counting Port
129 129  )))
130 130  
131 -= 2. Assembling the device =
129 += 2. Assembling =
132 132  
133 -== 2.1 Connecting the antenna ==
131 +Attach the LoRa antenna to the antenna connector, **ANT**,** **located on the top right side of the device, next to the upper screw terminal block. Secure the antenna by tightening it clockwise.
134 134  
135 -Connect the LoRa antenna to the antenna connector, **ANT**,** **located on the top right side of the device, next to the upper screw terminal block. Secure the antenna by tightening it clockwise.
136 -
137 -{{warning}}
138 -Warning! Do not power on the device without connecting the antenna.
139 -{{/warning}}
140 -
141 141  == 2.2 Terminals ==
142 142  
143 143  The  LT-22222-L has two screw terminal blocks. The upper screw treminal block has 6 terminals and the lower screw terminal block has 10 terminals.
... ... @@ -172,6 +172,8 @@
172 172  
173 173  The LT-22222-L I/O Controller can be powered by a **7–24V DC** power source. Connect your power supply’s positive wire to the VIN and the negative wire to the GND screw terminals. The power indicator **(PWR) LED** will turn on when the device is properly powered.
174 174  
167 +Powering on the device
168 +
175 175  Once powered, the **TX LED** will **fast-blink 5 times** which means the LT-22222-L will enter the **work mode** and start to **join** The Things Stack. The **TX LED** will be on for **5 seconds** after joining the network. When there is a **downlink** message from the server, the **RX LED** will be on for **1 second**. When the device is sending an uplink message to the server, the **TX LED** will be on for **1 second**. See also LED status.
176 176  
177 177  {{warning}}
... ... @@ -294,7 +294,7 @@
294 294  [[image:lt-22222-ul-payload-fmt.png||height="686" width="1000"]]
295 295  
296 296  
297 -== 3.3 Work Modes and Uplink Payload formats ==
291 +== 3.3 Work Modes and their Uplink Payload formats ==
298 298  
299 299  
300 300  The LT-22222-L has 5 **work modes**. It also has an interrupt/trigger mode for different types of applications that can be used together with any work mode as an additional feature. The default mode is MOD1 and you can switch between these modes using AT commands.
... ... @@ -318,12 +318,8 @@
318 318  (((
319 319  This is the default mode.
320 320  
321 -The uplink payload is 11 bytes long.
315 +The uplink payload is 11 bytes long. (% style="display:none" wfd-invisible="true" %)
322 322  
323 -(% style="color:red" %)**Note:The maximum count depends on the bytes it is.
324 -The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec).
325 -It starts counting again when it reaches the maximum value.**(% style="display:none" wfd-invisible="true" %)
326 -
327 327  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
328 328  |(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**
329 329  |Value|(((
... ... @@ -393,10 +393,6 @@
393 393  (((
394 394  The uplink payload is 11 bytes long.
395 395  
396 -(% style="color:red" %)**Note:The maximum count depends on the bytes it is.
397 -The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec).
398 -It starts counting again when it reaches the maximum value.**
399 -
400 400  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
401 401  |(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**4**|(% style="background-color:#4f81bd; color:white" %)**4**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**
402 402  |Value|COUNT1|COUNT2 |DIDORO*|(((
... ... @@ -461,9 +461,6 @@
461 461  
462 462  === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI ===
463 463  
464 -(% style="color:red" %)**Note: The maximum count depends on the bytes it is.
465 -The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec).
466 -It starts counting again when it reaches the maximum value.**
467 467  
468 468  **LT22222-L**: In this mode, the DI1 is used as a counting pin.
469 469  
... ... @@ -514,11 +514,7 @@
514 514  
515 515  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
516 516  
517 -(% style="color:red" %)**Note:The maximum count depends on the bytes it is.
518 -The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec).
519 -It starts counting again when it reaches the maximum value.**
520 520  
521 -
522 522  (((
523 523  **LT22222-L**: In this mode, the DI1 is used as a counting pin.
524 524  )))
... ... @@ -583,11 +583,7 @@
583 583  
584 584  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
585 585  
586 -(% style="color:red" %)**Note:The maximum count depends on the bytes it is.
587 -The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec).
588 -It starts counting again when it reaches the maximum value.**
589 589  
590 -
591 591  **LT22222-L**: In this mode, the DI1 is used as a counting pin.
592 592  
593 593  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
... ... @@ -860,10 +860,10 @@
860 860  (% style="color:#037691" %)**AT command**
861 861  
862 862  (% style="width:500px" %)
863 -|**Command**|AT+TDC<time>
864 -|**Response**|
865 -|**Parameters**|<time> uplink interval is in milliseconds
866 -|**Example**|(((
838 +|Command|AT+TDC<time>
839 +|Response|
840 +|Parameters|<time> uplink interval is in milliseconds
841 +|Example|(((
867 867  AT+TDC=30000
868 868  
869 869  Sets the uplink interval to 30,000 milliseconds (30 seconds)
... ... @@ -872,22 +872,20 @@
872 872  (% style="color:#037691" %)**Downlink payload**
873 873  
874 874  (% style="width:500px" %)
875 -|**Payload**|(((
850 +|Payload|(((
876 876  <prefix><time>
877 877  )))
878 -|**Parameters**|(((
853 +|Parameters|(((
879 879  <prefix> 0x01
880 880  
881 881  <time> uplink interval is in milliseconds, represented by 3  bytes in hexadecimal.
882 882  )))
883 -|**Example**|(((
858 +|Example|(((
884 884  01 **00 75 30**
885 885  
886 886  Sets the uplink interval to 30,000 milliseconds (30 seconds)
887 887  
888 -Conversion: 30000 (dec) = 00 75 30 (hex)
889 -
890 -See [[RapidTables>>https://www.rapidtables.com/convert/number/decimal-to-hex.html?x=30000]]
863 +Note: 00 75 30 (hex) = 30000 (dec)
891 891  )))
892 892  
893 893  ==== 3.4.2.2 Set the Work Mode (AT+MOD) ====
... ... @@ -1754,11 +1754,10 @@
1754 1754  
1755 1755  == 3.7 LEDs Indicators ==
1756 1756  
1757 -The table below lists the behavior of LED indicators for each port function.
1758 1758  
1759 1759  (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
1760 1760  |(% style="background-color:#4f81bd; color:white; width:50px" %)**LEDs**|(% style="background-color:#4f81bd; color:white; width:460px" %)**Feature**
1761 -|**PWR**|Always on when there is power
1733 +|**PWR**|Always on if there is power
1762 1762  |**TX**|(((
1763 1763  (((
1764 1764  Device boot: TX blinks 5 times.
... ... @@ -1765,7 +1765,7 @@
1765 1765  )))
1766 1766  
1767 1767  (((
1768 -Successful network join: TX remains ON for 5 seconds.
1740 +Successful join network: TX ON for 5 seconds.
1769 1769  )))
1770 1770  
1771 1771  (((
... ... @@ -1772,7 +1772,7 @@
1772 1772  Transmit a LoRa packet: TX blinks once
1773 1773  )))
1774 1774  )))
1775 -|**RX**|RX blinks once when a packet is received.
1747 +|**RX**|RX blinks once when receiving a packet.
1776 1776  |**DO1**|For LT-22222-L: ON when DO1 is low, OFF when DO1 is high
1777 1777  |**DO2**|For LT-22222-L: ON when DO2 is low, OFF when DO2 is high
1778 1778  |**DI1**|(((
... ... @@ -2004,14 +2004,14 @@
2004 2004  
2005 2005  == 5.1 Counting how many objects pass through the flow Line ==
2006 2006  
2007 -See [[How to set up to setup counting for objects passing through the flow line>>How to set up to count objects pass in flow line]]?
2008 2008  
1980 +Reference Link: [[How to set up to setup counting for objects passing through the flow line>>How to set up to count objects pass in flow line]]?
2009 2009  
1982 +
2010 2010  = 6. FAQ =
2011 2011  
2012 2012  This section contains some frequently asked questions, which can help you resolve common issues and find solutions quickly.
2013 2013  
2014 -
2015 2015  == 6.1 How to update the firmware? ==
2016 2016  
2017 2017  Dragino frequently releases firmware updates for the LT-22222-L.
... ... @@ -2068,6 +2068,8 @@
2068 2068  (((
2069 2069  (((
2070 2070  == 6.2 How to change the LoRaWAN frequency band/region? ==
2043 +
2044 +
2071 2071  )))
2072 2072  )))
2073 2073  
... ... @@ -2079,6 +2079,8 @@
2079 2079  
2080 2080  
2081 2081  == 6.3 How to setup LT to work with a Single Channel Gateway, such as LG01/LG02? ==
2056 +
2057 +
2082 2082  )))
2083 2083  
2084 2084  (((
... ... @@ -2149,11 +2149,13 @@
2149 2149  
2150 2150  == 6.4 How to change the uplink interval? ==
2151 2151  
2128 +
2152 2152  Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]]
2153 2153  
2154 2154  
2155 2155  == 6.5 Can I see the counting event in the serial output? ==
2156 2156  
2134 +
2157 2157  (((
2158 2158  You can run the AT command AT+DEBUG to view the counting event in the serial output. If the firmware is too old and doesn’t support AT+DEBUG, update to the latest firmware first.
2159 2159  
... ... @@ -2160,14 +2160,14 @@
2160 2160  
2161 2161  == 6.6 Can I use point-to-point communication with LT-22222-L? ==
2162 2162  
2163 -Yes, you can. Please refer to the [[Point-to-Point Communication of LT-22222-L>>https://wiki.dragino.com/xwiki/bin/view/Main/%20Point%20to%20Point%20Communication%20of%20LT-22222-L/]] page. The firmware that supports point-to-point communication can be found [[here>>https://github.com/dragino/LT-22222-L/releases]].
2164 2164  
2165 -
2142 +Yes, you can. Please refer to the [[Point-to-Point Communication of LT-22222-L>>https://wiki.dragino.com/xwiki/bin/view/Main/%20Point%20to%20Point%20Communication%20of%20LT-22222-L/]] page. The firmware that supports point-to-point communication can be found [[here>>https://github.com/dragino/LT-22222-L/releases]].
2166 2166  )))
2167 2167  
2168 2168  (((
2169 2169  == 6.7 Why does the relay output default to an open relay after the LT-22222-L is powered off? ==
2170 2170  
2148 +
2171 2171  * If the device is not properly shut down and is directly powered off.
2172 2172  * It will default to a power-off state.
2173 2173  * In modes 2 to 5, the DO/RO status and pulse count are saved to flash memory.
... ... @@ -2175,6 +2175,7 @@
2175 2175  
2176 2176  == 6.8 Can I setup LT-22222-L as a NC (Normally Closed) relay? ==
2177 2177  
2156 +
2178 2178  The LT-22222-L's built-in relay is Normally Open (NO). You can use an external relay to achieve a Normally Closed (NC) configuration. The circuit diagram is shown below:
2179 2179  
2180 2180  
... ... @@ -2183,24 +2183,24 @@
2183 2183  
2184 2184  == 6.9 Can the LT-22222-L save the RO state? ==
2185 2185  
2165 +
2186 2186  The firmware version must be at least 1.6.0.
2187 2187  
2188 2188  
2189 2189  == 6.10 Why does the LT-22222-L always report 15.585V when measuring the AVI? ==
2190 2190  
2171 +
2191 2191  It is likely that the GND is not connected during the measurement, or that the wire connected to the GND is loose.
2192 2192  
2193 2193  
2194 2194  = 7. Troubleshooting =
2195 -
2196 -This section provides some known troubleshooting tips.
2197 -
2198 -
2199 2199  )))
2200 2200  
2201 2201  (((
2202 2202  (((
2203 2203  == 7.1 Downlink isn't working. How can I solve this? ==
2181 +
2182 +
2204 2204  )))
2205 2205  )))
2206 2206  
... ... @@ -2212,6 +2212,8 @@
2212 2212  
2213 2213  
2214 2214  == 7.2 Having trouble uploading an image? ==
2194 +
2195 +
2215 2215  )))
2216 2216  
2217 2217  (((
... ... @@ -2222,6 +2222,8 @@
2222 2222  
2223 2223  
2224 2224  == 7.3 Why can't I join TTN in the US915 /AU915 bands? ==
2206 +
2207 +
2225 2225  )))
2226 2226  
2227 2227  (((
... ... @@ -2231,6 +2231,7 @@
2231 2231  
2232 2232  == 7.4 Why can the LT-22222-L perform Uplink normally, but cannot receive Downlink? ==
2233 2233  
2217 +
2234 2234  The FCD count of the gateway is inconsistent with the FCD count of the node, causing the downlink to remain in the queue.
2235 2235  Use this command to synchronize their counts: [[Resets the downlink packet count>>||anchor="H3.4.2.23Resetsthedownlinkpacketcount"]]
2236 2236  
... ... @@ -2237,6 +2237,7 @@
2237 2237  
2238 2238  = 8. Ordering information =
2239 2239  
2224 +
2240 2240  (% style="color:#4f81bd" %)**LT-22222-L-XXX:**
2241 2241  
2242 2242  (% style="color:#4f81bd" %)**XXX:**
... ... @@ -2253,6 +2253,7 @@
2253 2253  
2254 2254  = 9. Packing information =
2255 2255  
2241 +
2256 2256  **Package includes**:
2257 2257  
2258 2258  * 1 x LT-22222-L I/O Controller
... ... @@ -2269,6 +2269,7 @@
2269 2269  
2270 2270  = 10. Support =
2271 2271  
2258 +
2272 2272  * (((
2273 2273  Support is available Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different time zones, we cannot offer live support. However, your questions will be answered as soon as possible within the aforementioned schedule.
2274 2274  )))
... ... @@ -2280,6 +2280,7 @@
2280 2280  
2281 2281  = 11. Reference​​​​​ =
2282 2282  
2270 +
2283 2283  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
2284 2284  * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]]
2285 2285  * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0