Changes for page LSPH01 -- LoRaWAN Soil pH Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 17:52
Change comment:
Uploaded new attachment "image-20240330174400-2.png", version {1}
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -LSPH01-LoRaWAN Soil pH Sensor User Manual 1 +LSPH01 -- LoRaWAN Soil pH Sensor User Manual - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -462,15 +462,26 @@ 462 462 == 2.7 Calibration == 463 463 464 464 465 +(% style="color:blue" %)**Step1 :**(%%)** Clean probe** 466 + 467 +user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks new, users can clean it to remove hydrochloric acid or other liquids from the surface. 468 + 469 +(% style="color:blue" %)**Step2 :**(%%)** Immerse the sensor in ph buffer solution to make the sensor values stable** 470 + 465 465 ((( 466 466 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 473 + 474 +(% style="color:red" %)**Note: Only one ph buffer with one of the ph values needs to be calibrated during calibration. Wait for the sensor measurement value to be stable, it does not need to be the same as the ph marked by the ph buffer** 475 + 476 + 477 +(% style="color:blue" %)**Step3 :**(%%)** The numerically stable sensors were calibrated using commands** 467 467 ))) 468 468 469 469 ((( 470 - Afterstable, user can use below command to calibrate.481 + User can use below command to calibrate. 471 471 472 472 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 473 -|(% style="background-color:#4f81bd; color:white; width:1 15px" %)**pH buffer solution**|(% style="background-color:#4f81bd; color:white; width:145px" %)**AT Command to calibrate**|(% style="background-color:#4f81bd; color:white; width:150px" %)**Downlink Command**|(% style="background-color:#4f81bd; color:white; width:100px" %)**Read Cal Value**484 +|(% style="background-color:#4f81bd; color:white; width:120px" %)**pH buffer solution**|(% style="background-color:#4f81bd; color:white; width:150px" %)**AT Command to calibrate**|(% style="background-color:#4f81bd; color:white; width:145px" %)**Downlink Command**|(% style="background-color:#4f81bd; color:white; width:95px" %)**Read Cal Value** 474 474 |(% style="width:149px" %)4.00|(% style="width:197px" %)AT+PHCAL=4|(% style="width:206px" %)((( 475 475 0x13 04 476 476 Reply with Calibrate payload ... ... @@ -495,13 +495,25 @@ 495 495 ))) 496 496 ))) 497 497 509 +To use the AT COMMAND, refer to this link: 498 498 511 +* AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 512 + 513 +* AT Command via UART Connection : See [[UART Connection>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 514 + 515 +To use Downlink, take TTN as an example, please refer to this link: 516 + 517 +* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 518 + 519 +When the command is successfully used, the node sends a uplink. 520 +This is the payload for uplink 521 + 499 499 (% style="color:#037691" %)**Calibration Payload** 500 500 501 501 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:500px" %) 502 502 |=(% style="width: 60px;background-color:#4F81BD;color:white" %)((( 503 503 **Size(bytes)** 504 -)))|=(% style="width: 100px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 100px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 100px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 50px;background-color:#4F81BD;color:white" %)**7**|=(% style="width:90px;background-color:#4F81BD;color:white" %)**1** 527 +)))|=(% style="width: 100px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 100px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 100px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 50px;background-color:#4F81BD;color:white" %)**7**|=(% style="width: 90px;background-color:#4F81BD;color:white" %)**1** 505 505 |Value|((( 506 506 PH4 Calibrate value 507 507 )))|PH6.86 Calibrate value|((( ... ... @@ -521,6 +521,13 @@ 521 521 522 522 * Reply to non-confirmed packet: 14 00 523 523 547 +(% style="color:blue" %)**Step4 : **(%%)**After the calibration is completed, its measurement results in this ph buffer solution should be consistent with the numerical value of the command used in the calibration.** 548 + 549 +Examples: 550 +After using the command AT+PH=9 in 9.18ph buffer 551 +The readout returned by the sensor in 9.18ph buffer should be pH=9 552 + 553 + 524 524 == 2.8 Frequency Plans == 525 525 526 526
- image-20240330174324-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +445.4 KB - Content
- image-20240330174400-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +445.4 KB - Content