Last modified by Xiaoling on 2025/04/25 14:08

From version 99.24
edited by Xiaoling
on 2023/05/31 17:00
Change comment: There is no comment for this version
To version 99.23
edited by Xiaoling
on 2023/05/31 16:52
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -60,8 +60,6 @@
60 60  * IP68 rate for the Sensor Probe
61 61  * 8500mAh Battery for long term use
62 62  
63 -
64 -
65 65  == 1.3 Probe Specification ==
66 66  
67 67  
... ... @@ -82,15 +82,11 @@
82 82  * IP68 Protection
83 83  * Length: 3.5 meters
84 84  
85 -
86 -
87 87  == 1.4 ​Applications ==
88 88  
89 89  
90 90  * Smart Agriculture
91 91  
92 -
93 -
94 94  == 1.5 Pin mapping and power on ==
95 95  
96 96  
... ... @@ -293,8 +293,6 @@
293 293  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
294 294  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
295 295  
296 -
297 -
298 298  === 2.3.7 Decode payload in The Things Network ===
299 299  
300 300  
... ... @@ -386,8 +386,10 @@
386 386  
387 387  
388 388  (((
381 +(((
389 389  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
390 390  )))
384 +)))
391 391  
392 392  
393 393  === 2.6.2 Measurement ===
... ... @@ -394,11 +394,13 @@
394 394  
395 395  
396 396  (((
397 -(% style="color:blue" %)**Measurement the soil surface:**
391 +(% style="color:#4f81bd" %)**Measurement the soil surface:**
398 398  )))
399 399  
400 400  (((
401 401  [[image:1654592946732-634.png]]
396 +
397 +
402 402  )))
403 403  
404 404  (((
... ... @@ -422,7 +422,7 @@
422 422  )))
423 423  
424 424  (((
425 -(% style="color:blue" %)**Measurement inside soil:**
421 +(% style="color:#4f81bd" %)**Measurement inside soil:**
426 426  )))
427 427  
428 428  (((
... ... @@ -437,28 +437,24 @@
437 437  === 2.6.3 Maintain Probe ===
438 438  
439 439  
440 -(((
441 -~1. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
436 +1. (((
437 +pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
442 442  )))
443 -
444 -(((
445 -2. After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
439 +1. (((
440 +After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
446 446  )))
447 -
448 -(((
449 -3. Probe reference electrode is also no strong, need to avoid strong force or hitting.
442 +1. (((
443 +Probe reference electrode is also no strong, need to avoid strong force or hitting.
450 450  )))
451 -
452 -(((
453 -4. User should keep reference electrode wet while not use.
445 +1. (((
446 +User should keep reference electrode wet while not use.
454 454  )))
455 -
456 -(((
457 -5. Avoid the probes to touch oily matter. Which will cause issue in accuracy.
448 +1. (((
449 +Avoid the probes to touch oily matter. Which will cause issue in accuracy.
458 458  )))
451 +1. (((
452 +The probe is IP68 can be put in water.
459 459  
460 -(((
461 -6. The probe is IP68 can be put in water.
462 462  
463 463  
464 464  )))
... ... @@ -522,11 +522,8 @@
522 522  |(% style="width:183px" %)Get Calibration Version Info|(% style="width:55px" %)Any|(% style="width:93px" %)14|(% style="width:146px" %)2
523 523  
524 524  * Reply to the confirmation package: 14 01
525 -
526 526  * Reply to non-confirmed packet: 14 00
527 527  
528 -
529 -
530 530  == 2.8 Frequency Plans ==
531 531  
532 532  
... ... @@ -611,11 +611,8 @@
611 611  )))
612 612  
613 613  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
614 -
615 615  * Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
616 616  
617 -
618 -
619 619  === 2.8.3 CN470-510 (CN470) ===
620 620  
621 621  
... ... @@ -724,11 +724,8 @@
724 724  )))
725 725  
726 726  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
727 -
728 728  * Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
729 729  
730 -
731 -
732 732  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
733 733  
734 734  
... ... @@ -856,6 +856,9 @@
856 856  922.5 - SF7BW125 to SF12BW125
857 857  )))
858 858  
842 +(((
843 +
844 +)))
859 859  
860 860  (((
861 861  (% style="color:blue" %)**Uplink: (OTAA mode, channel added by JoinAccept message)**
... ... @@ -889,6 +889,9 @@
889 889  923.3 - SF7BW125 to SF12BW125
890 890  )))
891 891  
878 +(((
879 +
880 +)))
892 892  
893 893  (((
894 894  (% style="color:blue" %)**Downlink:**
... ... @@ -922,6 +922,9 @@
922 922  865.9850 - SF7BW125 to SF12BW125
923 923  )))
924 924  
914 +(((
915 +
916 +)))
925 925  
926 926  (((
927 927  (% style="color:blue" %)**Downlink:**
... ... @@ -942,11 +942,8 @@
942 942  The LSPH01 has an internal LED which is to show the status of different state.
943 943  
944 944  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
945 -
946 946  * Blink once when device transmit a packet.
947 947  
948 -
949 -
950 950  == 2.10 ​Firmware Change Log ==
951 951  
952 952  
... ... @@ -992,6 +992,9 @@
992 992  They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
993 993  )))
994 994  
984 +(((
985 +
986 +)))
995 995  
996 996  * (((
997 997  (% style="color:#4f81bd" %)** Commands special design for LSPH01**
... ... @@ -1082,11 +1082,13 @@
1082 1082  )))
1083 1083  * (((
1084 1084  Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
1077 +)))
1085 1085  
1086 -
1079 +(((
1087 1087  
1088 1088  )))
1089 1089  
1083 +
1090 1090  == 3.3 Calibrate Sensor ==
1091 1091  
1092 1092  
... ... @@ -1105,7 +1105,6 @@
1105 1105  |(% style="width:193px" %)Get Firmware Version Info|(% style="width:57px" %)Any|(% style="width:91px" %)26|(% style="width:149px" %)2
1106 1106  
1107 1107  * Reply to the confirmation package: 26 01
1108 -
1109 1109  * Reply to non-confirmed packet: 26 00
1110 1110  
1111 1111  Device will send an uplink after got this downlink command. With below payload:
... ... @@ -1243,8 +1243,6 @@
1243 1243  * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1244 1244  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1245 1245  
1246 -
1247 -
1248 1248  = 9. ​Packing Info =
1249 1249  
1250 1250  
... ... @@ -1259,8 +1259,6 @@
1259 1259  * Package Size / pcs : cm
1260 1260  * Weight / pcs : g
1261 1261  
1262 -
1263 -
1264 1264  = 10. ​Support =
1265 1265  
1266 1266