From version < 98.3 >
edited by Xiaoling
on 2022/06/30 11:59
To version < 98.17 >
edited by Xiaoling
on 2022/10/27 13:49
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -5,14 +5,6 @@
5 5  
6 6  
7 7  
8 -
9 -
10 -
11 -
12 -
13 -
14 -
15 -
16 16  **Table of Contents:**
17 17  
18 18  {{toc/}}
... ... @@ -22,17 +22,13 @@
22 22  
23 23  
24 24  
25 -
26 -
27 -
28 -
29 29  = 1. Introduction =
30 30  
19 +
31 31  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
32 32  
33 -(((
34 -
35 35  
23 +(((
36 36  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
37 37  )))
38 38  
... ... @@ -57,9 +57,9 @@
57 57  
58 58  
59 59  
60 -
61 61  == ​1.2 Features ==
62 62  
50 +
63 63  * LoRaWAN 1.0.3 Class A
64 64  * Ultra-low power consumption
65 65  * Monitor soil pH with temperature compensation.
... ... @@ -100,12 +100,13 @@
100 100  
101 101  == 1.4 ​Applications ==
102 102  
91 +
103 103  * Smart Agriculture
104 104  
105 105  
106 -
107 107  == 1.5 Pin mapping and power on ==
108 108  
97 +
109 109  [[image:1654592472094-134.png]]
110 110  
111 111  
... ... @@ -112,8 +112,10 @@
112 112  
113 113  = 2. Configure LSPH01 to connect to LoRaWAN network =
114 114  
104 +
115 115  == 2.1 How it works ==
116 116  
107 +
117 117  (((
118 118  The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
119 119  )))
... ... @@ -123,8 +123,10 @@
123 123  )))
124 124  
125 125  
117 +
126 126  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
127 127  
120 +
128 128  (((
129 129  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
130 130  )))
... ... @@ -190,6 +190,8 @@
190 190  
191 191  (((
192 192  (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
186 +
187 +
193 193  )))
194 194  
195 195  [[image:1654592697690-910.png]]
... ... @@ -198,6 +198,7 @@
198 198  
199 199  == 2.3 ​Uplink Payload ==
200 200  
196 +
201 201  (((
202 202  LSPH01 will uplink payload via LoRaWAN with below payload format: 
203 203  )))
... ... @@ -210,14 +210,11 @@
210 210  Normal uplink payload:
211 211  )))
212 212  
213 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
214 -|=(% style="width: 62.5px;" %)(((
215 -**Size (bytes)**
216 -)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1**
209 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:470px" %)
210 +|=(% style="width: 60px;" %)(((
211 +**Size (bytes)**)))|=(% style="width: 30px;" %)**2**|=(% style="width: 70px;" %)**2**|=(% style="width: 50px;" %)**2**|=(% style="width: 60px;" %)**2**|=(% style="width: 70px;" %)**1**|=(% style="width: 50px;" %)**1**|=(% style="width: 80px;" %)**1**
217 217  |(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)(((
218 -[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
219 -
220 -[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
213 +[[Temperature (Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
221 221  )))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
222 222  [[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
223 223  )))|Reserve|(((
... ... @@ -241,6 +241,7 @@
241 241  
242 242  === 2.3.2 DS18B20 Temperature sensor ===
243 243  
237 +
244 244  This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
245 245  
246 246  
... ... @@ -254,6 +254,7 @@
254 254  
255 255  === 2.3.3 Soil pH ===
256 256  
251 +
257 257  Range: 0 ~~ 14 pH
258 258  
259 259  **Example:**
... ... @@ -264,6 +264,7 @@
264 264  
265 265  === 2.3.4 Soil Temperature ===
266 266  
262 +
267 267  Get Soil Temperature 
268 268  
269 269  
... ... @@ -277,6 +277,7 @@
277 277  
278 278  === 2.3.5 Interrupt Pin ===
279 279  
276 +
280 280  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
281 281  
282 282  
... ... @@ -290,6 +290,7 @@
290 290  
291 291  === 2.3.6 Message Type ===
292 292  
290 +
293 293  (((
294 294  For a normal uplink payload, the message type is always 0x01.
295 295  )))
... ... @@ -299,7 +299,7 @@
299 299  )))
300 300  
301 301  
302 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:499px" %)
300 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:496px" %)
303 303  |=(% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload**
304 304  |(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
305 305  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
... ... @@ -319,7 +319,7 @@
319 319  )))
320 320  
321 321  (((
322 -LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
320 +LSPH01 TTN Payload Decoder:  [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
323 323  )))
324 324  
325 325  
... ... @@ -326,6 +326,7 @@
326 326  
327 327  == 2.4 Uplink Interval ==
328 328  
327 +
329 329  The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
330 330  
331 331  
... ... @@ -332,6 +332,7 @@
332 332  
333 333  == 2.5 ​Show Data in DataCake IoT Server ==
334 334  
334 +
335 335  (((
336 336  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
337 337  )))
... ... @@ -374,7 +374,7 @@
374 374  )))
375 375  
376 376  (((
377 -Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
377 +Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
378 378  )))
379 379  
380 380  
... ... @@ -395,8 +395,10 @@
395 395  
396 396  == 2.6 Installation and Maintain ==
397 397  
398 +
398 398  === 2.6.1 Before measurement ===
399 399  
401 +
400 400  (((
401 401  (((
402 402  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
... ... @@ -414,6 +414,8 @@
414 414  
415 415  (((
416 416  [[image:1654592946732-634.png]]
419 +
420 +
417 417  )))
418 418  
419 419  (((
... ... @@ -425,7 +425,7 @@
425 425  )))
426 426  
427 427  (((
428 -Slowly insert the probe to the measure point. Dont use large force which will break the probe. Make sure not shake when inserting.
432 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting.
429 429  )))
430 430  
431 431  (((
... ... @@ -452,6 +452,7 @@
452 452  
453 453  === 2.6.3 Maintain Probe ===
454 454  
459 +
455 455  1. (((
456 456  pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
457 457  )))
... ... @@ -476,6 +476,7 @@
476 476  
477 477  == 2.7 Calibration ==
478 478  
484 +
479 479  (((
480 480  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
481 481  )))
... ... @@ -515,15 +515,19 @@
515 515  * Reply to the confirmation package: 14 01
516 516  * Reply to non-confirmed packet: 14 00
517 517  
524 +
518 518  == 2.8 Frequency Plans ==
519 519  
527 +
520 520  (((
521 521  The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
522 522  )))
523 523  
524 524  
533 +
525 525  === 2.8.1 EU863-870 (EU868) ===
526 526  
536 +
527 527  (((
528 528  (% style="color:blue" %)**Uplink:**
529 529  )))
... ... @@ -584,6 +584,7 @@
584 584  
585 585  === 2.8.2 US902-928(US915) ===
586 586  
597 +
587 587  (((
588 588  Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
589 589  )))
... ... @@ -597,12 +597,13 @@
597 597  )))
598 598  
599 599  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
600 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
611 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
601 601  
602 602  
603 603  
604 604  === 2.8.3 CN470-510 (CN470) ===
605 605  
617 +
606 606  (((
607 607  Used in China, Default use CHE=1
608 608  )))
... ... @@ -691,6 +691,7 @@
691 691  
692 692  === 2.8.4 AU915-928(AU915) ===
693 693  
706 +
694 694  (((
695 695  Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
696 696  )))
... ... @@ -708,12 +708,13 @@
708 708  )))
709 709  
710 710  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
711 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
724 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
712 712  
713 713  
714 714  
715 715  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
716 716  
730 +
717 717  (((
718 718  (% style="color:blue" %)**Default Uplink channel:**
719 719  )))
... ... @@ -822,6 +822,7 @@
822 822  
823 823  === 2.8.6 KR920-923 (KR920) ===
824 824  
839 +
825 825  (((
826 826  (% style="color:blue" %)**Default channel:**
827 827  )))
... ... @@ -894,6 +894,7 @@
894 894  
895 895  === 2.8.7 IN865-867 (IN865) ===
896 896  
912 +
897 897  (((
898 898  (% style="color:blue" %)**Uplink:**
899 899  )))
... ... @@ -930,6 +930,7 @@
930 930  
931 931  == 2.9 LED Indicator ==
932 932  
949 +
933 933  The LSPH01 has an internal LED which is to show the status of different state.
934 934  
935 935  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
... ... @@ -940,11 +940,9 @@
940 940  == 2.10 ​Firmware Change Log ==
941 941  
942 942  
943 -**Firmware download link:**
960 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]]
944 944  
945 -[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
946 946  
947 -
948 948  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
949 949  
950 950  
... ... @@ -951,6 +951,7 @@
951 951  
952 952  = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
953 953  
969 +
954 954  (((
955 955  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
956 956  )))
... ... @@ -982,7 +982,7 @@
982 982  )))
983 983  
984 984  (((
985 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1001 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
986 986  )))
987 987  
988 988  (((
... ... @@ -1001,6 +1001,7 @@
1001 1001  
1002 1002  == 3.1 Set Transmit Interval Time ==
1003 1003  
1020 +
1004 1004  Feature: Change LoRaWAN End Node Transmit Interval.
1005 1005  
1006 1006  (% style="color:#037691" %)**AT Command: AT+TDC**
... ... @@ -1027,11 +1027,13 @@
1027 1027  Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1028 1028  
1029 1029  
1047 +
1030 1030  
1031 1031  )))
1032 1032  
1033 1033  == 3.2 Set Interrupt Mode ==
1034 1034  
1053 +
1035 1035  Feature, Set Interrupt mode for GPIO_EXIT.
1036 1036  
1037 1037  (% style="color:#037691" %)**AT Command: AT+INTMOD**
... ... @@ -1066,6 +1066,7 @@
1066 1066  
1067 1067  == 3.3 Calibrate Sensor ==
1068 1068  
1088 +
1069 1069  Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
1070 1070  
1071 1071  
... ... @@ -1072,6 +1072,7 @@
1072 1072  
1073 1073  == 3.4 Get Firmware Version Info ==
1074 1074  
1095 +
1075 1075  Feature: use downlink to get firmware version.
1076 1076  
1077 1077  (% style="color:#037691" %)**Downlink Command: 0x26**
... ... @@ -1154,8 +1154,10 @@
1154 1154  
1155 1155  = 4. Battery & How to replace =
1156 1156  
1178 +
1157 1157  == 4.1 Battery Type ==
1158 1158  
1181 +
1159 1159  (((
1160 1160  LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1161 1161  )))
... ... @@ -1162,6 +1162,8 @@
1162 1162  
1163 1163  (((
1164 1164  The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1188 +
1189 +
1165 1165  )))
1166 1166  
1167 1167  [[image:1654593587246-335.png]]
... ... @@ -1175,6 +1175,7 @@
1175 1175  
1176 1176  == 4.2 Replace Battery ==
1177 1177  
1203 +
1178 1178  (((
1179 1179  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
1180 1180  )))
... ... @@ -1187,6 +1187,7 @@
1187 1187  
1188 1188  == 4.3 Power Consumption Analyze ==
1189 1189  
1216 +
1190 1190  (((
1191 1191  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
1192 1192  )))
... ... @@ -1230,6 +1230,7 @@
1230 1230  
1231 1231  === 4.3.1 ​Battery Note ===
1232 1232  
1260 +
1233 1233  (((
1234 1234  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
1235 1235  )))
... ... @@ -1238,12 +1238,13 @@
1238 1238  
1239 1239  === ​4.3.2 Replace the battery ===
1240 1240  
1269 +
1241 1241  (((
1242 1242  You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
1243 1243  )))
1244 1244  
1245 1245  (((
1246 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user cant find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1275 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1247 1247  )))
1248 1248  
1249 1249  
... ... @@ -1250,12 +1250,16 @@
1250 1250  
1251 1251  = 5. Use AT Command =
1252 1252  
1282 +
1253 1253  == 5.1 Access AT Commands ==
1254 1254  
1285 +
1255 1255  LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
1256 1256  
1288 +
1257 1257  [[image:1654593668970-604.png]]
1258 1258  
1291 +
1259 1259  **Connection:**
1260 1260  
1261 1261  (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
... ... @@ -1277,16 +1277,21 @@
1277 1277  
1278 1278  = 6. FAQ =
1279 1279  
1313 +
1280 1280  == 6.1 How to change the LoRa Frequency Bands/Region ==
1281 1281  
1316 +
1282 1282  You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1283 1283  When downloading the images, choose the required image file for download. ​
1284 1284  
1285 1285  
1321 +
1286 1286  = 7. Trouble Shooting =
1287 1287  
1324 +
1288 1288  == 7.1 AT Commands input doesn't work ==
1289 1289  
1327 +
1290 1290  In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1291 1291  
1292 1292  
... ... @@ -1293,6 +1293,7 @@
1293 1293  
1294 1294  = 8. Order Info =
1295 1295  
1334 +
1296 1296  Part Number: (% style="color:blue" %)**LSPH01-XX**
1297 1297  
1298 1298  
... ... @@ -1325,6 +1325,7 @@
1325 1325  
1326 1326  = 10. ​Support =
1327 1327  
1367 +
1328 1328  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1329 1329  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
1330 1330  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0