Changes for page LSPH01 -- LoRaWAN Soil pH Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 17:52
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -5,6 +5,14 @@ 5 5 6 6 7 7 8 + 9 + 10 + 11 + 12 + 13 + 14 + 15 + 8 8 **Table of Contents:** 9 9 10 10 {{toc/}} ... ... @@ -14,13 +14,18 @@ 14 14 15 15 16 16 25 + 26 + 27 + 28 + 17 17 = 1. Introduction = 18 18 19 19 20 20 == 1.1 What is LoRaWAN Soil pH Sensor == 21 21 22 - 23 23 ((( 35 + 36 + 24 24 The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof. 25 25 ))) 26 26 ... ... @@ -45,6 +45,7 @@ 45 45 46 46 47 47 61 + 48 48 == 1.2 Features == 49 49 50 50 ... ... @@ -64,6 +64,8 @@ 64 64 65 65 66 66 81 + 82 + 67 67 == 1.3 Probe Specification == 68 68 69 69 ... ... @@ -86,6 +86,8 @@ 86 86 87 87 88 88 105 + 106 + 89 89 == 1.4 Applications == 90 90 91 91 ... ... @@ -93,6 +93,7 @@ 93 93 94 94 95 95 114 + 96 96 == 1.5 Pin mapping and power on == 97 97 98 98 ... ... @@ -207,12 +207,14 @@ 207 207 Normal uplink payload: 208 208 ))) 209 209 210 -(% border="1" cellspacing=" 5" style="background-color:#ffffcc; width:470px" %)211 -|=(% style="width: 6 0px;" %)(((212 -**Size(bytes)** 213 -)))|=(% style="width: 30px;" %)**2**|=(% style="width:70px;" %)**2**|=(% style="width: 50px;" %)**2**|=(% style="width: 60px;" %)**2**|=(% style="width: 70px;" %)**1**|=(% style="width: 50px;" %)**1**|=(% style="width: 80px;" %)**1**229 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %) 230 +|=(% style="width: 62.5px;" %)((( 231 +**Size (bytes)** 232 +)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1** 214 214 |(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)((( 215 -[[Temperature (Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]] 234 +[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]] 235 + 236 +[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]] 216 216 )))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|((( 217 217 [[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]] 218 218 )))|Reserve|((( ... ... @@ -299,7 +299,7 @@ 299 299 ))) 300 300 301 301 302 -(% border="1" cellspacing=" 5" style="background-color:#ffffcc; width:496px" %)323 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:499px" %) 303 303 |=(% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload** 304 304 |(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]] 305 305 |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]] ... ... @@ -307,9 +307,10 @@ 307 307 308 308 309 309 310 -=== 2.3.7 Decode payload in The Things Network === 311 311 312 312 333 +=== 2.3.7 Decode payload in The Things Network === 334 + 313 313 While using TTN network, you can add the payload format to decode the payload. 314 314 315 315 ... ... @@ -320,7 +320,7 @@ 320 320 ))) 321 321 322 322 ((( 323 -LSPH01 TTN Payload Decoder: [[https:~~/~~/ github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]345 +LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]] 324 324 ))) 325 325 326 326 ... ... @@ -484,7 +484,6 @@ 484 484 485 485 == 2.7 Calibration == 486 486 487 - 488 488 ((( 489 489 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 490 490 ))) ... ... @@ -498,16 +498,21 @@ 498 498 499 499 (% style="color:#037691" %)**Calibration Payload** 500 500 501 -(% border="1" cellspacing=" 5" style="background-color:#ffffcc; color:green; width:500px" %)502 -|=(% style="width: 6 0px;" %)(((522 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 523 +|=(% style="width: 62.5px;" %)((( 503 503 **Size (bytes)** 504 -)))|=(% style="width: 100px;" %)**1**|=(% style="width:100px;" %)**1**|=(% style="width:100px;" %)**1**|=(% style="width:50px;" %)**7**|=(% style="width: 90px;" %)**1**525 +)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1** 505 505 |**Value**|((( 506 -PH4 Calibrate value 527 +PH4 528 + 529 +Calibrate value 507 507 )))|PH6.86 Calibrate value|((( 508 -PH9.18 Calibrate value 531 +PH9.18 532 + 533 +Calibrate value 509 509 )))|Reserve|((( 510 510 [[Message Type>>||anchor="H2.3.6MessageType"]] 536 + 511 511 Always 0x03 512 512 ))) 513 513 ... ... @@ -520,19 +520,15 @@ 520 520 * Reply to non-confirmed packet: 14 00 521 521 522 522 523 - 524 524 == 2.8 Frequency Plans == 525 525 526 - 527 527 ((( 528 528 The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 529 529 ))) 530 530 531 531 532 - 533 533 === 2.8.1 EU863-870 (EU868) === 534 534 535 - 536 536 ((( 537 537 (% style="color:blue" %)**Uplink:** 538 538 ))) ... ... @@ -593,7 +593,6 @@ 593 593 594 594 === 2.8.2 US902-928(US915) === 595 595 596 - 597 597 ((( 598 598 Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document. 599 599 ))) ... ... @@ -609,11 +609,8 @@ 609 609 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 610 610 * Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 611 611 612 - 613 - 614 614 === 2.8.3 CN470-510 (CN470) === 615 615 616 - 617 617 ((( 618 618 Used in China, Default use CHE=1 619 619 ))) ... ... @@ -702,7 +702,6 @@ 702 702 703 703 === 2.8.4 AU915-928(AU915) === 704 704 705 - 706 706 ((( 707 707 Frequency band as per definition in LoRaWAN 1.0.3 Regional document. 708 708 ))) ... ... @@ -722,11 +722,8 @@ 722 722 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 723 723 * Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 724 724 725 - 726 - 727 727 === 2.8.5 AS920-923 & AS923-925 (AS923) === 728 728 729 - 730 730 ((( 731 731 (% style="color:blue" %)**Default Uplink channel:** 732 732 ))) ... ... @@ -835,7 +835,6 @@ 835 835 836 836 === 2.8.6 KR920-923 (KR920) === 837 837 838 - 839 839 ((( 840 840 (% style="color:blue" %)**Default channel:** 841 841 ))) ... ... @@ -908,7 +908,6 @@ 908 908 909 909 === 2.8.7 IN865-867 (IN865) === 910 910 911 - 912 912 ((( 913 913 (% style="color:blue" %)**Uplink:** 914 914 ))) ... ... @@ -945,20 +945,19 @@ 945 945 946 946 == 2.9 LED Indicator == 947 947 948 - 949 949 The LSPH01 has an internal LED which is to show the status of different state. 950 950 951 951 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. 952 952 * Blink once when device transmit a packet. 953 953 954 - 955 - 956 956 == 2.10 Firmware Change Log == 957 957 958 958 959 -**Firmware download link: [[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]]968 +**Firmware download link:** 960 960 970 +[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]] 961 961 972 + 962 962 **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]] 963 963 964 964 ... ... @@ -965,7 +965,6 @@ 965 965 966 966 = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink = 967 967 968 - 969 969 ((( 970 970 Use can configure LSPH01 via AT Command or LoRaWAN Downlink. 971 971 ))) ... ... @@ -1016,7 +1016,6 @@ 1016 1016 1017 1017 == 3.1 Set Transmit Interval Time == 1018 1018 1019 - 1020 1020 Feature: Change LoRaWAN End Node Transmit Interval. 1021 1021 1022 1022 (% style="color:#037691" %)**AT Command: AT+TDC** ... ... @@ -1043,13 +1043,11 @@ 1043 1043 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1044 1044 1045 1045 1046 - 1047 1047 1048 1048 ))) 1049 1049 1050 1050 == 3.2 Set Interrupt Mode == 1051 1051 1052 - 1053 1053 Feature, Set Interrupt mode for GPIO_EXIT. 1054 1054 1055 1055 (% style="color:#037691" %)**AT Command: AT+INTMOD** ... ... @@ -1081,10 +1081,8 @@ 1081 1081 ))) 1082 1082 1083 1083 1084 - 1085 1085 == 3.3 Calibrate Sensor == 1086 1086 1087 - 1088 1088 Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands 1089 1089 1090 1090 ... ... @@ -1091,7 +1091,6 @@ 1091 1091 1092 1092 == 3.4 Get Firmware Version Info == 1093 1093 1094 - 1095 1095 Feature: use downlink to get firmware version. 1096 1096 1097 1097 (% style="color:#037691" %)**Downlink Command: 0x26** ... ... @@ -1111,9 +1111,11 @@ 1111 1111 )))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1** 1112 1112 |**Value**|Software Type|((( 1113 1113 Frequency 1118 + 1114 1114 Band 1115 1115 )))|Sub-band|((( 1116 1116 Firmware 1122 + 1117 1117 Version 1118 1118 )))|Sensor Type|Reserve|((( 1119 1119 [[Message Type>>||anchor="H2.3.6MessageType"]] ... ... @@ -1120,8 +1120,6 @@ 1120 1120 Always 0x02 1121 1121 ))) 1122 1122 1123 - 1124 - 1125 1125 (% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01 1126 1126 1127 1127 ... ... @@ -1174,10 +1174,8 @@ 1174 1174 1175 1175 = 4. Battery & How to replace = 1176 1176 1177 - 1178 1178 == 4.1 Battery Type == 1179 1179 1180 - 1181 1181 ((( 1182 1182 LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 1183 1183 ))) ... ... @@ -1184,8 +1184,6 @@ 1184 1184 1185 1185 ((( 1186 1186 The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 1187 - 1188 - 1189 1189 ))) 1190 1190 1191 1191 [[image:1654593587246-335.png]] ... ... @@ -1199,7 +1199,6 @@ 1199 1199 1200 1200 == 4.2 Replace Battery == 1201 1201 1202 - 1203 1203 ((( 1204 1204 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 1205 1205 ))) ... ... @@ -1212,7 +1212,6 @@ 1212 1212 1213 1213 == 4.3 Power Consumption Analyze == 1214 1214 1215 - 1216 1216 ((( 1217 1217 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 1218 1218 ))) ... ... @@ -1256,7 +1256,6 @@ 1256 1256 1257 1257 === 4.3.1 Battery Note === 1258 1258 1259 - 1260 1260 ((( 1261 1261 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 1262 1262 ))) ... ... @@ -1265,7 +1265,6 @@ 1265 1265 1266 1266 === 4.3.2 Replace the battery === 1267 1267 1268 - 1269 1269 ((( 1270 1270 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 1271 1271 ))) ... ... @@ -1278,16 +1278,12 @@ 1278 1278 1279 1279 = 5. Use AT Command = 1280 1280 1281 - 1282 1282 == 5.1 Access AT Commands == 1283 1283 1284 - 1285 1285 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below. 1286 1286 1287 - 1288 1288 [[image:1654593668970-604.png]] 1289 1289 1290 - 1291 1291 **Connection:** 1292 1292 1293 1293 (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** ... ... @@ -1309,21 +1309,16 @@ 1309 1309 1310 1310 = 6. FAQ = 1311 1311 1312 - 1313 1313 == 6.1 How to change the LoRa Frequency Bands/Region == 1314 1314 1315 - 1316 1316 You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]]. 1317 1317 When downloading the images, choose the required image file for download. 1318 1318 1319 1319 1320 - 1321 1321 = 7. Trouble Shooting = 1322 1322 1323 - 1324 1324 == 7.1 AT Commands input doesn't work == 1325 1325 1326 - 1327 1327 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1328 1328 1329 1329 ... ... @@ -1330,7 +1330,6 @@ 1330 1330 1331 1331 = 8. Order Info = 1332 1332 1333 - 1334 1334 Part Number: (% style="color:blue" %)**LSPH01-XX** 1335 1335 1336 1336 ... ... @@ -1346,7 +1346,6 @@ 1346 1346 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1347 1347 1348 1348 1349 - 1350 1350 = 9. Packing Info = 1351 1351 1352 1352 ... ... @@ -1362,10 +1362,8 @@ 1362 1362 * Weight / pcs : g 1363 1363 1364 1364 1365 - 1366 1366 = 10. Support = 1367 1367 1368 - 1369 1369 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1370 1370 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]. 1371 1371