<
From version < 98.10 >
edited by Xiaoling
on 2022/08/18 16:35
To version < 86.1 >
edited by Xiaoling
on 2022/06/10 10:59
>
Change comment: Uploaded new attachment "image-20220610105907-1.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -4,7 +4,62 @@
4 4  
5 5  
6 6  
7 +**Contents:**
7 7  
9 +* [[1. Introduction>>path:#H1.Introduction]]
10 +** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 +** [[​1.2 Features>>path:#H200B1.2Features]]
12 +** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 +** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 +** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 +* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 +** [[2.1 How it works>>path:#H2.1Howitworks]]
17 +** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 +** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 +*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 +*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 +*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 +*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 +*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 +*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 +*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 +** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 +** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 +** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 +*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 +*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 +*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 +** [[2.7 Calibration>>path:#H2.7Calibration]]
33 +** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 +*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 +*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 +*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 +*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 +*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 +*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 +*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 +** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 +** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 +* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 +** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 +** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 +** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 +** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 +* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 +** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 +** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 +** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 +*** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 +*** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 +* [[5. Use AT Command>>path:#H5.UseATCommand]]
55 +** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 +* [[6. FAQ>>path:#H6.FAQ]]
57 +** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 +* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 +** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 +* [[8. Order Info>>path:#H8.OrderInfo]]
61 +* [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 +* [[10. ​Support>>path:#H10.A0200BSupport]]
8 8  
9 9  
10 10  
... ... @@ -11,29 +11,11 @@
11 11  
12 12  
13 13  
14 -
15 -
16 -**Table of Contents:**
17 -
18 -{{toc/}}
19 -
20 -
21 -
22 -
23 -
24 -
25 -
26 -
27 -
28 -
29 29  = 1. Introduction =
30 30  
31 -
32 32  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
33 33  
34 34  (((
35 -
36 -
37 37  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
38 38  )))
39 39  
... ... @@ -61,7 +61,6 @@
61 61  
62 62  == ​1.2 Features ==
63 63  
64 -
65 65  * LoRaWAN 1.0.3 Class A
66 66  * Ultra-low power consumption
67 67  * Monitor soil pH with temperature compensation.
... ... @@ -78,8 +78,6 @@
78 78  
79 79  
80 80  
81 -
82 -
83 83  == 1.3 Probe Specification ==
84 84  
85 85  
... ... @@ -102,19 +102,14 @@
102 102  
103 103  
104 104  
105 -
106 -
107 107  == 1.4 ​Applications ==
108 108  
109 -
110 110  * Smart Agriculture
111 111  
112 112  
113 113  
114 -
115 115  == 1.5 Pin mapping and power on ==
116 116  
117 -
118 118  [[image:1654592472094-134.png]]
119 119  
120 120  
... ... @@ -121,23 +121,19 @@
121 121  
122 122  = 2. Configure LSPH01 to connect to LoRaWAN network =
123 123  
124 -
125 125  == 2.1 How it works ==
126 126  
127 -
128 128  (((
129 129  The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
130 130  )))
131 131  
132 132  (((
133 -In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
160 +In case you cant set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
134 134  )))
135 135  
136 136  
137 -
138 138  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
139 139  
140 -
141 141  (((
142 142  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
143 143  )))
... ... @@ -144,14 +144,10 @@
144 144  
145 145  (((
146 146  [[image:1654592492399-921.png]]
147 -
148 -
149 149  )))
150 150  
151 151  (((
152 152  The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
153 -
154 -
155 155  )))
156 156  
157 157  (((
... ... @@ -175,13 +175,11 @@
175 175  [[image:1654592600093-601.png]]
176 176  
177 177  
178 -
179 179  **Add APP EUI and DEV EUI**
180 180  
181 181  [[image:1654592619856-881.png]]
182 182  
183 183  
184 -
185 185  **Add APP EUI in the application**
186 186  
187 187  [[image:1654592632656-512.png]]
... ... @@ -203,8 +203,6 @@
203 203  
204 204  (((
205 205  (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
206 -
207 -
208 208  )))
209 209  
210 210  [[image:1654592697690-910.png]]
... ... @@ -213,7 +213,6 @@
213 213  
214 214  == 2.3 ​Uplink Payload ==
215 215  
216 -
217 217  (((
218 218  LSPH01 will uplink payload via LoRaWAN with below payload format: 
219 219  )))
... ... @@ -257,7 +257,6 @@
257 257  
258 258  === 2.3.2 DS18B20 Temperature sensor ===
259 259  
260 -
261 261  This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
262 262  
263 263  
... ... @@ -271,7 +271,6 @@
271 271  
272 272  === 2.3.3 Soil pH ===
273 273  
274 -
275 275  Range: 0 ~~ 14 pH
276 276  
277 277  **Example:**
... ... @@ -282,7 +282,6 @@
282 282  
283 283  === 2.3.4 Soil Temperature ===
284 284  
285 -
286 286  Get Soil Temperature 
287 287  
288 288  
... ... @@ -296,7 +296,6 @@
296 296  
297 297  === 2.3.5 Interrupt Pin ===
298 298  
299 -
300 300  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
301 301  
302 302  
... ... @@ -310,7 +310,6 @@
310 310  
311 311  === 2.3.6 Message Type ===
312 312  
313 -
314 314  (((
315 315  For a normal uplink payload, the message type is always 0x01.
316 316  )))
... ... @@ -328,8 +328,6 @@
328 328  
329 329  
330 330  
331 -
332 -
333 333  === 2.3.7 Decode payload in The Things Network ===
334 334  
335 335  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -342,7 +342,7 @@
342 342  )))
343 343  
344 344  (((
345 -LSPH01 TTN Payload Decoder:  [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
354 +LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
346 346  )))
347 347  
348 348  
... ... @@ -349,7 +349,6 @@
349 349  
350 350  == 2.4 Uplink Interval ==
351 351  
352 -
353 353  The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
354 354  
355 355  
... ... @@ -356,7 +356,6 @@
356 356  
357 357  == 2.5 ​Show Data in DataCake IoT Server ==
358 358  
359 -
360 360  (((
361 361  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
362 362  )))
... ... @@ -399,7 +399,7 @@
399 399  )))
400 400  
401 401  (((
402 -Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
409 +Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
403 403  )))
404 404  
405 405  
... ... @@ -420,10 +420,8 @@
420 420  
421 421  == 2.6 Installation and Maintain ==
422 422  
423 -
424 424  === 2.6.1 Before measurement ===
425 425  
426 -
427 427  (((
428 428  (((
429 429  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
... ... @@ -441,8 +441,6 @@
441 441  
442 442  (((
443 443  [[image:1654592946732-634.png]]
444 -
445 -
446 446  )))
447 447  
448 448  (((
... ... @@ -454,7 +454,7 @@
454 454  )))
455 455  
456 456  (((
457 -Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting.
460 +Slowly insert the probe to the measure point. Dont use large force which will break the probe. Make sure not shake when inserting.
458 458  )))
459 459  
460 460  (((
... ... @@ -481,7 +481,6 @@
481 481  
482 482  === 2.6.3 Maintain Probe ===
483 483  
484 -
485 485  1. (((
486 486  pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
487 487  )))
... ... @@ -506,7 +506,6 @@
506 506  
507 507  == 2.7 Calibration ==
508 508  
509 -
510 510  (((
511 511  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
512 512  )))
... ... @@ -538,7 +538,6 @@
538 538  Always 0x03
539 539  )))
540 540  
541 -
542 542  User can also send 0x14 downlink command to poll the current calibration payload.
543 543  
544 544  [[image:image-20220607171416-7.jpeg]]
... ... @@ -552,16 +552,13 @@
552 552  
553 553  == 2.8 Frequency Plans ==
554 554  
555 -
556 556  (((
557 557  The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
558 558  )))
559 559  
560 560  
561 -
562 562  === 2.8.1 EU863-870 (EU868) ===
563 563  
564 -
565 565  (((
566 566  (% style="color:blue" %)**Uplink:**
567 567  )))
... ... @@ -622,7 +622,6 @@
622 622  
623 623  === 2.8.2 US902-928(US915) ===
624 624  
625 -
626 626  (((
627 627  Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
628 628  )))
... ... @@ -636,15 +636,13 @@
636 636  )))
637 637  
638 638  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
639 -* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
635 +* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
640 640  
641 641  
642 642  
643 643  
644 -
645 645  === 2.8.3 CN470-510 (CN470) ===
646 646  
647 -
648 648  (((
649 649  Used in China, Default use CHE=1
650 650  )))
... ... @@ -733,7 +733,6 @@
733 733  
734 734  === 2.8.4 AU915-928(AU915) ===
735 735  
736 -
737 737  (((
738 738  Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
739 739  )))
... ... @@ -751,15 +751,12 @@
751 751  )))
752 752  
753 753  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
754 -* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
747 +* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
755 755  
756 756  
757 757  
758 -
759 -
760 760  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
761 761  
762 -
763 763  (((
764 764  (% style="color:blue" %)**Default Uplink channel:**
765 765  )))
... ... @@ -868,7 +868,6 @@
868 868  
869 869  === 2.8.6 KR920-923 (KR920) ===
870 870  
871 -
872 872  (((
873 873  (% style="color:blue" %)**Default channel:**
874 874  )))
... ... @@ -941,7 +941,6 @@
941 941  
942 942  === 2.8.7 IN865-867 (IN865) ===
943 943  
944 -
945 945  (((
946 946  (% style="color:blue" %)**Uplink:**
947 947  )))
... ... @@ -978,7 +978,6 @@
978 978  
979 979  == 2.9 LED Indicator ==
980 980  
981 -
982 982  The LSPH01 has an internal LED which is to show the status of different state.
983 983  
984 984  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
... ... @@ -986,14 +986,14 @@
986 986  
987 987  
988 988  
989 -
990 -
991 991  == 2.10 ​Firmware Change Log ==
992 992  
993 993  
994 -**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]]
979 +**Firmware download link:**
995 995  
981 +[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
996 996  
983 +
997 997  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
998 998  
999 999  
... ... @@ -1000,7 +1000,6 @@
1000 1000  
1001 1001  = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
1002 1002  
1003 -
1004 1004  (((
1005 1005  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
1006 1006  )))
... ... @@ -1032,7 +1032,7 @@
1032 1032  )))
1033 1033  
1034 1034  (((
1035 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1021 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1036 1036  )))
1037 1037  
1038 1038  (((
... ... @@ -1058,6 +1058,7 @@
1058 1058  [[image:image-20220607171554-8.png]]
1059 1059  
1060 1060  
1047 +
1061 1061  (((
1062 1062  (% style="color:#037691" %)**Downlink Command: 0x01**
1063 1063  )))
... ... @@ -1086,7 +1086,7 @@
1086 1086  
1087 1087  (% style="color:#037691" %)**AT Command: AT+INTMOD**
1088 1088  
1089 -[[image:image-20220610105907-1.png]]
1076 +[[image:image-20220607171716-9.png]]
1090 1090  
1091 1091  
1092 1092  (((
... ... @@ -1113,6 +1113,7 @@
1113 1113  )))
1114 1114  
1115 1115  
1103 +
1116 1116  == 3.3 Calibrate Sensor ==
1117 1117  
1118 1118  Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
... ... @@ -1151,10 +1151,10 @@
1151 1151  Always 0x02
1152 1152  )))
1153 1153  
1154 -(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01
1142 +**Software Type**: Always 0x03 for LSPH01
1155 1155  
1156 1156  
1157 -(% style="color:#037691" %)**Frequency Band**:
1145 +**Frequency Band**:
1158 1158  
1159 1159  *0x01: EU868
1160 1160  
... ... @@ -1177,13 +1177,13 @@
1177 1177  *0xa0: AS923-3
1178 1178  
1179 1179  
1180 -(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08
1168 +**Sub-Band**: value 0x00 ~~ 0x08
1181 1181  
1182 1182  
1183 -(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
1171 +**Firmware Version**: 0x0100, Means: v1.0.0 version
1184 1184  
1185 1185  
1186 -(% style="color:#037691" %)**Sensor Type**:
1174 +**Sensor Type**:
1187 1187  
1188 1188  0x01: LSE01
1189 1189  
... ... @@ -1210,7 +1210,7 @@
1210 1210  )))
1211 1211  
1212 1212  (((
1213 -The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1201 +The discharge curve is not linear so cant simply use percentage to show the battery level. Below is the battery performance.
1214 1214  )))
1215 1215  
1216 1216  [[image:1654593587246-335.png]]
... ... @@ -1245,12 +1245,12 @@
1245 1245  )))
1246 1246  
1247 1247  
1248 -(% style="color:#037691" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1236 +**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1249 1249  
1250 1250  [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1251 1251  
1252 1252  
1253 -(% style="color:#037691" %)**Step 2**(%%): Open it and choose
1241 +**Step 2**: Open it and choose
1254 1254  
1255 1255  * Product Model
1256 1256  * Uplink Interval
... ... @@ -1264,13 +1264,13 @@
1264 1264  The battery related documents as below:
1265 1265  
1266 1266  * (((
1267 -[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
1255 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1268 1268  )))
1269 1269  * (((
1270 1270  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1271 1271  )))
1272 1272  * (((
1273 -[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
1261 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1274 1274  )))
1275 1275  
1276 1276  [[image:image-20220607172042-11.png]]
... ... @@ -1288,11 +1288,11 @@
1288 1288  === ​4.3.2 Replace the battery ===
1289 1289  
1290 1290  (((
1291 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
1279 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there wont be voltage drop between battery and main board.
1292 1292  )))
1293 1293  
1294 1294  (((
1295 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1283 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user cant find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1296 1296  )))
1297 1297  
1298 1298  
... ... @@ -1334,9 +1334,9 @@
1334 1334  
1335 1335  = 7. Trouble Shooting =
1336 1336  
1337 -== 7.1 AT Commands input doesn't work ==
1325 +== 7.1 AT Commands input doesnt work ==
1338 1338  
1339 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1327 +In the case if user can see the console output but cant type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1340 1340  
1341 1341  
1342 1342  
... ... @@ -1356,7 +1356,6 @@
1356 1356  * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1357 1357  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1358 1358  
1359 -
1360 1360  = 9. ​Packing Info =
1361 1361  
1362 1362  
... ... @@ -1371,7 +1371,6 @@
1371 1371  * Package Size / pcs : cm
1372 1372  * Weight / pcs : g
1373 1373  
1374 -
1375 1375  = 10. ​Support =
1376 1376  
1377 1377  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0