Changes for page LSPH01 -- LoRaWAN Soil pH Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 17:52
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -9,6 +9,10 @@ 9 9 10 10 11 11 12 + 13 + 14 + 15 + 12 12 **Table of Contents:** 13 13 14 14 {{toc/}} ... ... @@ -71,7 +71,6 @@ 71 71 * 8500mAh Battery for long term use 72 72 73 73 74 - 75 75 == 1.3 Probe Specification == 76 76 77 77 ... ... @@ -93,13 +93,11 @@ 93 93 * Length: 3.5 meters 94 94 95 95 96 - 97 97 == 1.4 Applications == 98 98 99 99 * Smart Agriculture 100 100 101 101 102 - 103 103 == 1.5 Pin mapping and power on == 104 104 105 105 [[image:1654592472094-134.png]] ... ... @@ -115,7 +115,7 @@ 115 115 ))) 116 116 117 117 ((( 118 -In case you can ’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.119 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01. 119 119 ))) 120 120 121 121 ... ... @@ -302,7 +302,6 @@ 302 302 |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]] 303 303 304 304 305 - 306 306 === 2.3.7 Decode payload in The Things Network === 307 307 308 308 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -513,8 +513,6 @@ 513 513 514 514 515 515 516 - 517 - 518 518 == 2.8 Frequency Plans == 519 519 520 520 ((( ... ... @@ -597,10 +597,9 @@ 597 597 ))) 598 598 599 599 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 600 -* Use the Join successful sub-band if the server doesn ’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)598 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 601 601 602 602 603 - 604 604 === 2.8.3 CN470-510 (CN470) === 605 605 606 606 ((( ... ... @@ -708,10 +708,9 @@ 708 708 ))) 709 709 710 710 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 711 -* Use the Join successful sub-band if the server doesn ’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)708 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 712 712 713 713 714 - 715 715 === 2.8.5 AS920-923 & AS923-925 (AS923) === 716 716 717 717 ((( ... ... @@ -936,7 +936,6 @@ 936 936 * Blink once when device transmit a packet. 937 937 938 938 939 - 940 940 == 2.10 Firmware Change Log == 941 941 942 942 ... ... @@ -982,7 +982,7 @@ 982 982 ))) 983 983 984 984 ((( 985 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 980 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 986 986 ))) 987 987 988 988 ((( ... ... @@ -1063,7 +1063,6 @@ 1063 1063 ))) 1064 1064 1065 1065 1066 - 1067 1067 == 3.3 Calibrate Sensor == 1068 1068 1069 1069 Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands ... ... @@ -1243,7 +1243,7 @@ 1243 1243 ))) 1244 1244 1245 1245 ((( 1246 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can ’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)1240 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 1247 1247 ))) 1248 1248 1249 1249 ... ... @@ -1307,6 +1307,8 @@ 1307 1307 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1308 1308 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1309 1309 1304 + 1305 + 1310 1310 = 9. Packing Info = 1311 1311 1312 1312 ... ... @@ -1321,6 +1321,8 @@ 1321 1321 * Package Size / pcs : cm 1322 1322 * Weight / pcs : g 1323 1323 1320 + 1321 + 1324 1324 = 10. Support = 1325 1325 1326 1326 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.