From version < 90.8 >
edited by Xiaoling
on 2022/06/25 16:57
To version < 98.12 >
edited by Xiaoling
on 2022/10/13 17:14
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,65 +4,19 @@
4 4  
5 5  
6 6  
7 +
7 7  **Table of Contents:**
8 8  
9 -* [[1. Introduction>>path:#H1.Introduction]]
10 -** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 -** [[​1.2 Features>>path:#H200B1.2Features]]
12 -** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 -** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 -** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 -* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 -** [[2.1 How it works>>path:#H2.1Howitworks]]
17 -** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 -** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 -*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 -*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 -*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 -*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 -*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 -*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 -*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 -** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 -** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 -** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 -*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 -*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 -*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 -** [[2.7 Calibration>>path:#H2.7Calibration]]
33 -** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 -*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 -*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 -*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 -*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 -*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 -*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 -*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 -** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 -** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 -* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 -** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 -** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 -** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 -** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 -* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 -** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 -** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 -** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 -*** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 -*** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 -* [[5. Use AT Command>>path:#H5.UseATCommand]]
55 -** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 -* [[6. FAQ>>path:#H6.FAQ]]
57 -** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 -* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 -** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 -* [[8. Order Info>>path:#H8.OrderInfo]]
61 -* [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 -* [[10. ​Support>>path:#H10.A0200BSupport]]
10 +{{toc/}}
63 63  
12 +
13 +
14 +
15 +
16 +
64 64  = 1. Introduction =
65 65  
19 +
66 66  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
67 67  
68 68  (((
... ... @@ -92,9 +92,9 @@
92 92  
93 93  
94 94  
95 -
96 96  == ​1.2 Features ==
97 97  
51 +
98 98  * LoRaWAN 1.0.3 Class A
99 99  * Ultra-low power consumption
100 100  * Monitor soil pH with temperature compensation.
... ... @@ -109,6 +109,9 @@
109 109  * IP68 rate for the Sensor Probe
110 110  * 8500mAh Battery for long term use
111 111  
66 +
67 +
68 +
112 112  == 1.3 Probe Specification ==
113 113  
114 114  
... ... @@ -129,12 +129,19 @@
129 129  * IP68 Protection
130 130  * Length: 3.5 meters
131 131  
89 +
90 +
91 +
132 132  == 1.4 ​Applications ==
133 133  
94 +
134 134  * Smart Agriculture
135 135  
97 +
98 +
136 136  == 1.5 Pin mapping and power on ==
137 137  
101 +
138 138  [[image:1654592472094-134.png]]
139 139  
140 140  
... ... @@ -141,19 +141,23 @@
141 141  
142 142  = 2. Configure LSPH01 to connect to LoRaWAN network =
143 143  
108 +
144 144  == 2.1 How it works ==
145 145  
111 +
146 146  (((
147 147  The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
148 148  )))
149 149  
150 150  (((
151 -In case you cant set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
117 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
152 152  )))
153 153  
154 154  
121 +
155 155  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
156 156  
124 +
157 157  (((
158 158  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
159 159  )))
... ... @@ -219,6 +219,8 @@
219 219  
220 220  (((
221 221  (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
190 +
191 +
222 222  )))
223 223  
224 224  [[image:1654592697690-910.png]]
... ... @@ -227,6 +227,7 @@
227 227  
228 228  == 2.3 ​Uplink Payload ==
229 229  
200 +
230 230  (((
231 231  LSPH01 will uplink payload via LoRaWAN with below payload format: 
232 232  )))
... ... @@ -270,6 +270,7 @@
270 270  
271 271  === 2.3.2 DS18B20 Temperature sensor ===
272 272  
244 +
273 273  This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
274 274  
275 275  
... ... @@ -283,6 +283,7 @@
283 283  
284 284  === 2.3.3 Soil pH ===
285 285  
258 +
286 286  Range: 0 ~~ 14 pH
287 287  
288 288  **Example:**
... ... @@ -293,6 +293,7 @@
293 293  
294 294  === 2.3.4 Soil Temperature ===
295 295  
269 +
296 296  Get Soil Temperature 
297 297  
298 298  
... ... @@ -306,6 +306,7 @@
306 306  
307 307  === 2.3.5 Interrupt Pin ===
308 308  
283 +
309 309  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
310 310  
311 311  
... ... @@ -319,6 +319,7 @@
319 319  
320 320  === 2.3.6 Message Type ===
321 321  
297 +
322 322  (((
323 323  For a normal uplink payload, the message type is always 0x01.
324 324  )))
... ... @@ -337,8 +337,6 @@
337 337  
338 338  
339 339  
340 -
341 -
342 342  === 2.3.7 Decode payload in The Things Network ===
343 343  
344 344  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -351,7 +351,7 @@
351 351  )))
352 352  
353 353  (((
354 -LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
328 +LSPH01 TTN Payload Decoder:  [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
355 355  )))
356 356  
357 357  
... ... @@ -358,6 +358,7 @@
358 358  
359 359  == 2.4 Uplink Interval ==
360 360  
335 +
361 361  The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
362 362  
363 363  
... ... @@ -364,6 +364,7 @@
364 364  
365 365  == 2.5 ​Show Data in DataCake IoT Server ==
366 366  
342 +
367 367  (((
368 368  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
369 369  )))
... ... @@ -406,7 +406,7 @@
406 406  )))
407 407  
408 408  (((
409 -Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
385 +Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
410 410  )))
411 411  
412 412  
... ... @@ -427,8 +427,10 @@
427 427  
428 428  == 2.6 Installation and Maintain ==
429 429  
406 +
430 430  === 2.6.1 Before measurement ===
431 431  
409 +
432 432  (((
433 433  (((
434 434  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
... ... @@ -446,6 +446,8 @@
446 446  
447 447  (((
448 448  [[image:1654592946732-634.png]]
427 +
428 +
449 449  )))
450 450  
451 451  (((
... ... @@ -457,7 +457,7 @@
457 457  )))
458 458  
459 459  (((
460 -Slowly insert the probe to the measure point. Dont use large force which will break the probe. Make sure not shake when inserting.
440 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting.
461 461  )))
462 462  
463 463  (((
... ... @@ -484,6 +484,7 @@
484 484  
485 485  === 2.6.3 Maintain Probe ===
486 486  
467 +
487 487  1. (((
488 488  pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
489 489  )))
... ... @@ -508,6 +508,7 @@
508 508  
509 509  == 2.7 Calibration ==
510 510  
492 +
511 511  (((
512 512  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
513 513  )))
... ... @@ -548,15 +548,19 @@
548 548  * Reply to non-confirmed packet: 14 00
549 549  
550 550  
533 +
551 551  == 2.8 Frequency Plans ==
552 552  
536 +
553 553  (((
554 554  The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
555 555  )))
556 556  
557 557  
542 +
558 558  === 2.8.1 EU863-870 (EU868) ===
559 559  
545 +
560 560  (((
561 561  (% style="color:blue" %)**Uplink:**
562 562  )))
... ... @@ -617,6 +617,7 @@
617 617  
618 618  === 2.8.2 US902-928(US915) ===
619 619  
606 +
620 620  (((
621 621  Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
622 622  )))
... ... @@ -630,15 +630,14 @@
630 630  )))
631 631  
632 632  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
633 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
620 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
634 634  
635 635  
636 636  
637 637  
638 -
639 -
640 640  === 2.8.3 CN470-510 (CN470) ===
641 641  
627 +
642 642  (((
643 643  Used in China, Default use CHE=1
644 644  )))
... ... @@ -727,6 +727,7 @@
727 727  
728 728  === 2.8.4 AU915-928(AU915) ===
729 729  
716 +
730 730  (((
731 731  Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
732 732  )))
... ... @@ -744,15 +744,14 @@
744 744  )))
745 745  
746 746  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
747 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
734 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
748 748  
749 749  
750 750  
751 751  
752 -
753 -
754 754  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
755 755  
741 +
756 756  (((
757 757  (% style="color:blue" %)**Default Uplink channel:**
758 758  )))
... ... @@ -861,6 +861,7 @@
861 861  
862 862  === 2.8.6 KR920-923 (KR920) ===
863 863  
850 +
864 864  (((
865 865  (% style="color:blue" %)**Default channel:**
866 866  )))
... ... @@ -933,6 +933,7 @@
933 933  
934 934  === 2.8.7 IN865-867 (IN865) ===
935 935  
923 +
936 936  (((
937 937  (% style="color:blue" %)**Uplink:**
938 938  )))
... ... @@ -969,6 +969,7 @@
969 969  
970 970  == 2.9 LED Indicator ==
971 971  
960 +
972 972  The LSPH01 has an internal LED which is to show the status of different state.
973 973  
974 974  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
... ... @@ -977,16 +977,12 @@
977 977  
978 978  
979 979  
980 -
981 -
982 982  == 2.10 ​Firmware Change Log ==
983 983  
984 984  
985 -**Firmware download link:**
972 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]]
986 986  
987 -[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
988 988  
989 -
990 990  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
991 991  
992 992  
... ... @@ -993,6 +993,7 @@
993 993  
994 994  = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
995 995  
981 +
996 996  (((
997 997  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
998 998  )))
... ... @@ -1024,7 +1024,7 @@
1024 1024  )))
1025 1025  
1026 1026  (((
1027 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1013 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1028 1028  )))
1029 1029  
1030 1030  (((
... ... @@ -1043,6 +1043,7 @@
1043 1043  
1044 1044  == 3.1 Set Transmit Interval Time ==
1045 1045  
1032 +
1046 1046  Feature: Change LoRaWAN End Node Transmit Interval.
1047 1047  
1048 1048  (% style="color:#037691" %)**AT Command: AT+TDC**
... ... @@ -1069,11 +1069,13 @@
1069 1069  Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1070 1070  
1071 1071  
1059 +
1072 1072  
1073 1073  )))
1074 1074  
1075 1075  == 3.2 Set Interrupt Mode ==
1076 1076  
1065 +
1077 1077  Feature, Set Interrupt mode for GPIO_EXIT.
1078 1078  
1079 1079  (% style="color:#037691" %)**AT Command: AT+INTMOD**
... ... @@ -1108,6 +1108,7 @@
1108 1108  
1109 1109  == 3.3 Calibrate Sensor ==
1110 1110  
1100 +
1111 1111  Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
1112 1112  
1113 1113  
... ... @@ -1114,6 +1114,7 @@
1114 1114  
1115 1115  == 3.4 Get Firmware Version Info ==
1116 1116  
1107 +
1117 1117  Feature: use downlink to get firmware version.
1118 1118  
1119 1119  (% style="color:#037691" %)**Downlink Command: 0x26**
... ... @@ -1196,8 +1196,10 @@
1196 1196  
1197 1197  = 4. Battery & How to replace =
1198 1198  
1190 +
1199 1199  == 4.1 Battery Type ==
1200 1200  
1193 +
1201 1201  (((
1202 1202  LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1203 1203  )))
... ... @@ -1204,6 +1204,8 @@
1204 1204  
1205 1205  (((
1206 1206  The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1200 +
1201 +
1207 1207  )))
1208 1208  
1209 1209  [[image:1654593587246-335.png]]
... ... @@ -1217,6 +1217,7 @@
1217 1217  
1218 1218  == 4.2 Replace Battery ==
1219 1219  
1215 +
1220 1220  (((
1221 1221  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
1222 1222  )))
... ... @@ -1229,6 +1229,7 @@
1229 1229  
1230 1230  == 4.3 Power Consumption Analyze ==
1231 1231  
1228 +
1232 1232  (((
1233 1233  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
1234 1234  )))
... ... @@ -1238,7 +1238,7 @@
1238 1238  )))
1239 1239  
1240 1240  
1241 -(% style="color:red" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1238 +(% style="color:#037691" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1242 1242  
1243 1243  [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1244 1244  
... ... @@ -1272,6 +1272,7 @@
1272 1272  
1273 1273  === 4.3.1 ​Battery Note ===
1274 1274  
1272 +
1275 1275  (((
1276 1276  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
1277 1277  )))
... ... @@ -1280,12 +1280,13 @@
1280 1280  
1281 1281  === ​4.3.2 Replace the battery ===
1282 1282  
1281 +
1283 1283  (((
1284 1284  You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
1285 1285  )))
1286 1286  
1287 1287  (((
1288 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user cant find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1287 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1289 1289  )))
1290 1290  
1291 1291  
... ... @@ -1292,12 +1292,16 @@
1292 1292  
1293 1293  = 5. Use AT Command =
1294 1294  
1294 +
1295 1295  == 5.1 Access AT Commands ==
1296 1296  
1297 +
1297 1297  LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
1298 1298  
1300 +
1299 1299  [[image:1654593668970-604.png]]
1300 1300  
1303 +
1301 1301  **Connection:**
1302 1302  
1303 1303  (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
... ... @@ -1319,16 +1319,21 @@
1319 1319  
1320 1320  = 6. FAQ =
1321 1321  
1325 +
1322 1322  == 6.1 How to change the LoRa Frequency Bands/Region ==
1323 1323  
1328 +
1324 1324  You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1325 1325  When downloading the images, choose the required image file for download. ​
1326 1326  
1327 1327  
1333 +
1328 1328  = 7. Trouble Shooting =
1329 1329  
1336 +
1330 1330  == 7.1 AT Commands input doesn't work ==
1331 1331  
1339 +
1332 1332  In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1333 1333  
1334 1334  
... ... @@ -1335,6 +1335,7 @@
1335 1335  
1336 1336  = 8. Order Info =
1337 1337  
1346 +
1338 1338  Part Number: (% style="color:blue" %)**LSPH01-XX**
1339 1339  
1340 1340  
... ... @@ -1351,7 +1351,6 @@
1351 1351  
1352 1352  
1353 1353  
1354 -
1355 1355  = 9. ​Packing Info =
1356 1356  
1357 1357  
... ... @@ -1368,10 +1368,11 @@
1368 1368  
1369 1369  
1370 1370  
1371 -
1372 1372  = 10. ​Support =
1373 1373  
1381 +
1374 1374  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1375 1375  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
1376 1376  
1385 +
1377 1377  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0