Changes for page LSPH01 -- LoRaWAN Soil pH Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 17:52
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,70 +4,23 @@ 4 4 5 5 6 6 7 + 7 7 **Table of Contents:** 8 8 9 -* [[1. Introduction>>path:#H1.Introduction]] 10 -** [[1.1 What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]] 11 -** [[1.2 Features>>path:#H200B1.2Features]] 12 -** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]] 13 -** [[1.4 Applications>>path:#H1.4200BApplications]] 14 -** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]] 15 -* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]] 16 -** [[2.1 How it works>>path:#H2.1Howitworks]] 17 -** [[2.2 Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]] 18 -** [[2.3 Uplink Payload>>path:#H2.3200BUplinkPayload]] 19 -*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]] 20 -*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]] 21 -*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]] 22 -*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]] 23 -*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]] 24 -*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]] 25 -*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]] 26 -** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]] 27 -** [[2.5 Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]] 28 -** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]] 29 -*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]] 30 -*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]] 31 -*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]] 32 -** [[2.7 Calibration>>path:#H2.7Calibration]] 33 -** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]] 34 -*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]] 35 -*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]] 36 -*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]] 37 -*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]] 38 -*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]] 39 -*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]] 40 -*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]] 41 -** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]] 42 -** [[2.10 Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]] 43 -* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]] 44 -** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]] 45 -** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]] 46 -** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]] 47 -** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]] 48 -* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]] 49 -** [[4.1 Battery Type>>path:#H4.1BatteryType]] 50 -** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]] 51 -** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]] 52 -*** [[4.3.1 Battery Note>>path:#H4.3.1200BBatteryNote]] 53 -*** [[4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]] 54 -* [[5. Use AT Command>>path:#H5.UseATCommand]] 55 -** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]] 56 -* [[6. FAQ>>path:#H6.FAQ]] 57 -** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]] 58 -* [[7. Trouble Shooting>>path:#H7.TroubleShooting]] 59 -** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]] 60 -* [[8. Order Info>>path:#H8.OrderInfo]] 61 -* [[9. Packing Info>>path:#H9.200BPackingInfo]] 62 -* [[10. Support>>path:#H10.A0200BSupport]] 10 +{{toc/}} 63 63 12 + 13 + 14 + 15 + 16 + 64 64 = 1. Introduction = 65 65 19 + 66 66 == 1.1 What is LoRaWAN Soil pH Sensor == 67 67 68 -((( 69 - 70 70 23 +((( 71 71 The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof. 72 72 ))) 73 73 ... ... @@ -92,9 +92,9 @@ 92 92 93 93 94 94 95 - 96 96 == 1.2 Features == 97 97 50 + 98 98 * LoRaWAN 1.0.3 Class A 99 99 * Ultra-low power consumption 100 100 * Monitor soil pH with temperature compensation. ... ... @@ -109,6 +109,8 @@ 109 109 * IP68 rate for the Sensor Probe 110 110 * 8500mAh Battery for long term use 111 111 65 + 66 + 112 112 == 1.3 Probe Specification == 113 113 114 114 ... ... @@ -129,12 +129,17 @@ 129 129 * IP68 Protection 130 130 * Length: 3.5 meters 131 131 87 + 88 + 132 132 == 1.4 Applications == 133 133 91 + 134 134 * Smart Agriculture 135 135 94 + 136 136 == 1.5 Pin mapping and power on == 137 137 97 + 138 138 [[image:1654592472094-134.png]] 139 139 140 140 ... ... @@ -141,19 +141,23 @@ 141 141 142 142 = 2. Configure LSPH01 to connect to LoRaWAN network = 143 143 104 + 144 144 == 2.1 How it works == 145 145 107 + 146 146 ((( 147 147 The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 148 148 ))) 149 149 150 150 ((( 151 -In case you can ’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.113 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01. 152 152 ))) 153 153 154 154 117 + 155 155 == 2.2 Quick guide to connect to LoRaWAN server (OTAA) == 156 156 120 + 157 157 ((( 158 158 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example. 159 159 ))) ... ... @@ -219,6 +219,8 @@ 219 219 220 220 ((( 221 221 (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel. 186 + 187 + 222 222 ))) 223 223 224 224 [[image:1654592697690-910.png]] ... ... @@ -227,6 +227,7 @@ 227 227 228 228 == 2.3 Uplink Payload == 229 229 196 + 230 230 ((( 231 231 LSPH01 will uplink payload via LoRaWAN with below payload format: 232 232 ))) ... ... @@ -239,14 +239,11 @@ 239 239 Normal uplink payload: 240 240 ))) 241 241 242 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %) 243 -|=(% style="width: 62.5px;" %)((( 244 -**Size (bytes)** 245 -)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1** 209 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:510px" %) 210 +|=(% style="width: 60px;" %)((( 211 +**Size (bytes)**)))|=(% style="width: 30px;" %)**2**|=(% style="width: 70px;" %)**2**|=(% style="width: 70px;" %)**2**|=(% style="width: 60px;" %)**2**|=(% style="width: 70px;" %)**1**|=(% style="width: 50px;" %)**1**|=(% style="width: 80px;" %)**1** 246 246 |(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)((( 247 -[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]] 248 - 249 -[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]] 213 +[[Temperature (Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]] 250 250 )))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|((( 251 251 [[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]] 252 252 )))|Reserve|((( ... ... @@ -270,6 +270,7 @@ 270 270 271 271 === 2.3.2 DS18B20 Temperature sensor === 272 272 237 + 273 273 This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature. 274 274 275 275 ... ... @@ -283,6 +283,7 @@ 283 283 284 284 === 2.3.3 Soil pH === 285 285 251 + 286 286 Range: 0 ~~ 14 pH 287 287 288 288 **Example:** ... ... @@ -293,6 +293,7 @@ 293 293 294 294 === 2.3.4 Soil Temperature === 295 295 262 + 296 296 Get Soil Temperature 297 297 298 298 ... ... @@ -306,6 +306,7 @@ 306 306 307 307 === 2.3.5 Interrupt Pin === 308 308 276 + 309 309 This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up. 310 310 311 311 ... ... @@ -319,6 +319,7 @@ 319 319 320 320 === 2.3.6 Message Type === 321 321 290 + 322 322 ((( 323 323 For a normal uplink payload, the message type is always 0x01. 324 324 ))) ... ... @@ -334,6 +334,8 @@ 334 334 |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]] 335 335 |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]] 336 336 306 + 307 + 337 337 === 2.3.7 Decode payload in The Things Network === 338 338 339 339 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -346,7 +346,7 @@ 346 346 ))) 347 347 348 348 ((( 349 -LSPH01 TTN Payload Decoder: www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]320 +LSPH01 TTN Payload Decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 350 350 ))) 351 351 352 352 ... ... @@ -353,6 +353,7 @@ 353 353 354 354 == 2.4 Uplink Interval == 355 355 327 + 356 356 The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] 357 357 358 358 ... ... @@ -359,6 +359,7 @@ 359 359 360 360 == 2.5 Show Data in DataCake IoT Server == 361 361 334 + 362 362 ((( 363 363 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 364 364 ))) ... ... @@ -401,7 +401,7 @@ 401 401 ))) 402 402 403 403 ((( 404 -Download Datacake decoder from: [[https:~~/~~/www.dr agino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]377 +Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]] 405 405 ))) 406 406 407 407 ... ... @@ -422,8 +422,10 @@ 422 422 423 423 == 2.6 Installation and Maintain == 424 424 398 + 425 425 === 2.6.1 Before measurement === 426 426 401 + 427 427 ((( 428 428 ((( 429 429 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. ... ... @@ -441,6 +441,8 @@ 441 441 442 442 ((( 443 443 [[image:1654592946732-634.png]] 419 + 420 + 444 444 ))) 445 445 446 446 ((( ... ... @@ -452,7 +452,7 @@ 452 452 ))) 453 453 454 454 ((( 455 -Slowly insert the probe to the measure point. Don ’t use large force which will break the probe. Make sure not shake when inserting.432 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting. 456 456 ))) 457 457 458 458 ((( ... ... @@ -479,6 +479,7 @@ 479 479 480 480 === 2.6.3 Maintain Probe === 481 481 459 + 482 482 1. ((( 483 483 pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 484 484 ))) ... ... @@ -503,6 +503,7 @@ 503 503 504 504 == 2.7 Calibration == 505 505 484 + 506 506 ((( 507 507 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 508 508 ))) ... ... @@ -545,13 +545,16 @@ 545 545 546 546 == 2.8 Frequency Plans == 547 547 527 + 548 548 ((( 549 549 The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 550 550 ))) 551 551 552 552 533 + 553 553 === 2.8.1 EU863-870 (EU868) === 554 554 536 + 555 555 ((( 556 556 (% style="color:blue" %)**Uplink:** 557 557 ))) ... ... @@ -612,6 +612,7 @@ 612 612 613 613 === 2.8.2 US902-928(US915) === 614 614 597 + 615 615 ((( 616 616 Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document. 617 617 ))) ... ... @@ -625,15 +625,13 @@ 625 625 ))) 626 626 627 627 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 628 -* Use the Join successful sub-band if the server doesn ’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)611 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 629 629 630 630 631 631 632 - 633 - 634 - 635 635 === 2.8.3 CN470-510 (CN470) === 636 636 617 + 637 637 ((( 638 638 Used in China, Default use CHE=1 639 639 ))) ... ... @@ -722,6 +722,7 @@ 722 722 723 723 === 2.8.4 AU915-928(AU915) === 724 724 706 + 725 725 ((( 726 726 Frequency band as per definition in LoRaWAN 1.0.3 Regional document. 727 727 ))) ... ... @@ -739,15 +739,13 @@ 739 739 ))) 740 740 741 741 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 742 -* Use the Join successful sub-band if the server doesn ’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)724 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 743 743 744 744 745 745 746 - 747 - 748 - 749 749 === 2.8.5 AS920-923 & AS923-925 (AS923) === 750 750 730 + 751 751 ((( 752 752 (% style="color:blue" %)**Default Uplink channel:** 753 753 ))) ... ... @@ -856,6 +856,7 @@ 856 856 857 857 === 2.8.6 KR920-923 (KR920) === 858 858 839 + 859 859 ((( 860 860 (% style="color:blue" %)**Default channel:** 861 861 ))) ... ... @@ -928,6 +928,7 @@ 928 928 929 929 === 2.8.7 IN865-867 (IN865) === 930 930 912 + 931 931 ((( 932 932 (% style="color:blue" %)**Uplink:** 933 933 ))) ... ... @@ -964,6 +964,7 @@ 964 964 965 965 == 2.9 LED Indicator == 966 966 949 + 967 967 The LSPH01 has an internal LED which is to show the status of different state. 968 968 969 969 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. ... ... @@ -971,17 +971,12 @@ 971 971 972 972 973 973 974 - 975 - 976 - 977 977 == 2.10 Firmware Change Log == 978 978 979 979 980 -**Firmware download link:** 960 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]] 981 981 982 -[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]] 983 983 984 - 985 985 **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]] 986 986 987 987 ... ... @@ -988,6 +988,7 @@ 988 988 989 989 = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink = 990 990 969 + 991 991 ((( 992 992 Use can configure LSPH01 via AT Command or LoRaWAN Downlink. 993 993 ))) ... ... @@ -1019,7 +1019,7 @@ 1019 1019 ))) 1020 1020 1021 1021 ((( 1022 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1001 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1023 1023 ))) 1024 1024 1025 1025 ((( ... ... @@ -1038,6 +1038,7 @@ 1038 1038 1039 1039 == 3.1 Set Transmit Interval Time == 1040 1040 1020 + 1041 1041 Feature: Change LoRaWAN End Node Transmit Interval. 1042 1042 1043 1043 (% style="color:#037691" %)**AT Command: AT+TDC** ... ... @@ -1064,11 +1064,13 @@ 1064 1064 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1065 1065 1066 1066 1047 + 1067 1067 1068 1068 ))) 1069 1069 1070 1070 == 3.2 Set Interrupt Mode == 1071 1071 1053 + 1072 1072 Feature, Set Interrupt mode for GPIO_EXIT. 1073 1073 1074 1074 (% style="color:#037691" %)**AT Command: AT+INTMOD** ... ... @@ -1103,6 +1103,7 @@ 1103 1103 1104 1104 == 3.3 Calibrate Sensor == 1105 1105 1088 + 1106 1106 Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands 1107 1107 1108 1108 ... ... @@ -1109,6 +1109,7 @@ 1109 1109 1110 1110 == 3.4 Get Firmware Version Info == 1111 1111 1095 + 1112 1112 Feature: use downlink to get firmware version. 1113 1113 1114 1114 (% style="color:#037691" %)**Downlink Command: 0x26** ... ... @@ -1191,8 +1191,10 @@ 1191 1191 1192 1192 = 4. Battery & How to replace = 1193 1193 1178 + 1194 1194 == 4.1 Battery Type == 1195 1195 1181 + 1196 1196 ((( 1197 1197 LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 1198 1198 ))) ... ... @@ -1199,6 +1199,8 @@ 1199 1199 1200 1200 ((( 1201 1201 The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 1188 + 1189 + 1202 1202 ))) 1203 1203 1204 1204 [[image:1654593587246-335.png]] ... ... @@ -1212,6 +1212,7 @@ 1212 1212 1213 1213 == 4.2 Replace Battery == 1214 1214 1203 + 1215 1215 ((( 1216 1216 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 1217 1217 ))) ... ... @@ -1224,6 +1224,7 @@ 1224 1224 1225 1225 == 4.3 Power Consumption Analyze == 1226 1226 1216 + 1227 1227 ((( 1228 1228 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 1229 1229 ))) ... ... @@ -1233,7 +1233,7 @@ 1233 1233 ))) 1234 1234 1235 1235 1236 -(% style="color: red" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:1226 +(% style="color:#037691" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 1237 1237 1238 1238 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 1239 1239 ... ... @@ -1267,6 +1267,7 @@ 1267 1267 1268 1268 === 4.3.1 Battery Note === 1269 1269 1260 + 1270 1270 ((( 1271 1271 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 1272 1272 ))) ... ... @@ -1275,12 +1275,13 @@ 1275 1275 1276 1276 === 4.3.2 Replace the battery === 1277 1277 1269 + 1278 1278 ((( 1279 1279 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 1280 1280 ))) 1281 1281 1282 1282 ((( 1283 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can ’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)1275 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 1284 1284 ))) 1285 1285 1286 1286 ... ... @@ -1287,12 +1287,16 @@ 1287 1287 1288 1288 = 5. Use AT Command = 1289 1289 1282 + 1290 1290 == 5.1 Access AT Commands == 1291 1291 1285 + 1292 1292 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below. 1293 1293 1288 + 1294 1294 [[image:1654593668970-604.png]] 1295 1295 1291 + 1296 1296 **Connection:** 1297 1297 1298 1298 (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** ... ... @@ -1314,16 +1314,21 @@ 1314 1314 1315 1315 = 6. FAQ = 1316 1316 1313 + 1317 1317 == 6.1 How to change the LoRa Frequency Bands/Region == 1318 1318 1316 + 1319 1319 You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]]. 1320 1320 When downloading the images, choose the required image file for download. 1321 1321 1322 1322 1321 + 1323 1323 = 7. Trouble Shooting = 1324 1324 1324 + 1325 1325 == 7.1 AT Commands input doesn't work == 1326 1326 1327 + 1327 1327 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1328 1328 1329 1329 ... ... @@ -1330,6 +1330,7 @@ 1330 1330 1331 1331 = 8. Order Info = 1332 1332 1334 + 1333 1333 Part Number: (% style="color:blue" %)**LSPH01-XX** 1334 1334 1335 1335 ... ... @@ -1345,8 +1345,6 @@ 1345 1345 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1346 1346 1347 1347 1348 - 1349 - 1350 1350 = 9. Packing Info = 1351 1351 1352 1352 ... ... @@ -1362,10 +1362,9 @@ 1362 1362 * Weight / pcs : g 1363 1363 1364 1364 1365 - 1366 - 1367 1367 = 10. Support = 1368 1368 1367 + 1369 1369 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1370 1370 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]. 1371 1371