71 +
65 65  = 1. Introduction =
66 66  
67 67  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
68 68  
69 69  (((
70 -
71 -
72 72  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
73 73  )))
74 74  
... ... @@ -93,7 +93,6 @@
93 93  
94 94  
95 95  
96 -
97 97  == ​1.2 Features ==
98 98  
99 99  * LoRaWAN 1.0.3 Class A
... ... @@ -110,6 +110,8 @@
110 110  * IP68 rate for the Sensor Probe
111 111  * 8500mAh Battery for long term use
112 112  
117 +
118 +
113 113  == 1.3 Probe Specification ==
114 114  
115 115  
... ... @@ -130,10 +130,14 @@
130 130  * IP68 Protection
131 131  * Length: 3.5 meters
132 132  
139 +
140 +
133 133  == 1.4 ​Applications ==
134 134  
135 135  * Smart Agriculture
136 136  
145 +
146 +
137 137  == 1.5 Pin mapping and power on ==
138 138  
139 139  [[image:1654592472094-134.png]]
... ... @@ -149,7 +149,7 @@
149 149  )))
150 150  
151 151  (((
152 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
162 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>path:#H5.UseATCommand]]to set the keys in the LSPH01.
153 153  )))
154 154  
155 155  
... ... @@ -161,14 +161,10 @@
161 161  
162 162  (((
163 163  [[image:1654592492399-921.png]]
164 -
165 -
166 166  )))
167 167  
168 168  (((
169 169  The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
170 -
171 -
172 172  )))
173 173  
174 174  (((
... ... @@ -192,13 +192,11 @@
192 192  [[image:1654592600093-601.png]]
193 193  
194 194  
195 -
196 196  **Add APP EUI and DEV EUI**
197 197  
198 198  [[image:1654592619856-881.png]]
199 199  
200 200  
201 -
202 202  **Add APP EUI in the application**
203 203  
204 204  [[image:1654592632656-512.png]]
... ... @@ -241,17 +241,19 @@
241 241  )))
242 242  
243 243  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
244 -|=(% style="width: 62.5px;" %)(((
245 -**Size (bytes)**
246 -)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1**
247 -|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)(((
248 -[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
248 +|(((
249 +**Size**
249 249  
250 -[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
251 -)))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
252 -[[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
251 +**(bytes)**
252 +)))|**2**|**2**|**2**|**2**|**1**|**1**|**1**
253 +|**Value**|[[BAT>>path:#H2.3.1BatteryInfo]]|(((
254 +[[Temperature>>path:#H2.3.2DS18B20Temperaturesensor]]
255 +
256 +[[(Optional)>>path:#H2.3.2DS18B20Temperaturesensor]]
257 +)))|[[Soil pH>>path:#H2.3.3SoilpH]]|[[Soil Temperature>>path:#H2.3.4SoilTemperature]]|(((
258 +[[Digital Interrupt (Optional)>>path:#H2.3.5InterruptPin]]
253 253  )))|Reserve|(((
254 -[[Message Type>>||anchor="H2.3.6MessageType"]]
260 +[[Message Type>>path:#H2.3.6MessageType]]
255 255  )))
256 256  
257 257  [[image:1654592721645-318.png]]
... ... @@ -307,7 +307,7 @@
307 307  
308 308  === 2.3.5 Interrupt Pin ===
309 309  
310 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
316 +This data field shows if this packet is generated by interrupt or not. [[Click here>>path:#H3.2SetInterruptMode]] for the hardware and software set up.
311 311  
312 312  
313 313  **Example:**
... ... @@ -329,11 +329,11 @@
329 329  )))
330 330  
331 331  
332 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:499px" %)
333 -|=(% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload**
334 -|(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
335 -|(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
336 -|(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
338 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
339 +|=**Message Type Code**|=**Description**|=**Payload**
340 +|0x01|Normal Uplink|[[Normal Uplink Payload>>path:#H2.3200BUplinkPayload]]
341 +|0x02|Reply configures info|[[Configure Info Payload>>path:#H3.4GetFirmwareVersionInfo]]
342 +|0x03|Reply Calibration Info|[[Calibration Payload>>path:#H2.7Calibration]]
337 337  
338 338  === 2.3.7 Decode payload in The Things Network ===
339 339  
... ... @@ -354,7 +354,7 @@
354 354  
355 355  == 2.4 Uplink Interval ==
356 356  
357 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
363 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
358 358  
359 359  
360 360  
... ... @@ -518,9 +518,11 @@
518 518  (% style="color:#037691" %)**Calibration Payload**
519 519  
520 520  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
521 -|=(% style="width: 62.5px;" %)(((
522 -**Size (bytes)**
523 -)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1**
527 +|(((
528 +**Size**
529 +
530 +**(bytes)**
531 +)))|**1**|**1**|**1**|**7**|**1**
524 524  |**Value**|(((
525 525  PH4
526 526  
... ... @@ -530,7 +530,7 @@
530 530  
531 531  Calibrate value
532 532  )))|Reserve|(((
533 -[[Message Type>>||anchor="H2.3.6MessageType"]]
541 +[[Message Type>>path:#H2.3.6MessageType]]
534 534  
535 535  Always 0x03
536 536  )))
... ... @@ -963,6 +963,8 @@
963 963  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
964 964  * Blink once when device transmit a packet.
965 965  
974 +
975 +
966 966  == 2.10 ​Firmware Change Log ==
967 967  
968 968  
... ... @@ -982,7 +982,7 @@
982 982  )))
983 983  
984 984  * (((
985 -AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
995 +AT Command Connection: See [[FAQ>>path:#H6.FAQ]].
986 986  )))
987 987  * (((
988 988  LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
... ... @@ -1034,6 +1034,7 @@
1034 1034  [[image:image-20220607171554-8.png]]
1035 1035  
1036 1036  
1047 +
1037 1037  (((
1038 1038  (% style="color:#037691" %)**Downlink Command: 0x01**
1039 1039  )))
... ... @@ -1062,7 +1062,7 @@
1062 1062  
1063 1063  (% style="color:#037691" %)**AT Command: AT+INTMOD**
1064 1064  
1065 -[[image:image-20220610105907-1.png]]
1076 +[[image:image-20220607171716-9.png]]
1066 1066  
1067 1067  
1068 1068  (((
... ... @@ -1092,7 +1092,7 @@
1092 1092  
1093 1093  == 3.3 Calibrate Sensor ==
1094 1094  
1095 -Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
1106 +Detail See [[Calibration Guide>>path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands
1096 1096  
1097 1097  
1098 1098  
... ... @@ -1124,7 +1124,7 @@
1124 1124  
1125 1125  Version
1126 1126  )))|Sensor Type|Reserve|(((
1127 -[[Message Type>>||anchor="H2.3.6MessageType"]]
1138 +[[Message Type>>path:#H2.3.6MessageType]]
1128 1128  Always 0x02
1129 1129  )))
1130 1130  
... ... @@ -1187,7 +1187,7 @@
1187 1187  )))
1188 1188  
1189 1189  (((
1190 -The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1201 +The discharge curve is not linear so cant simply use percentage to show the battery level. Below is the battery performance.
1191 1191  )))
1192 1192  
1193 1193  [[image:1654593587246-335.png]]
... ... @@ -1241,13 +1241,13 @@
1241 1241  The battery related documents as below:
1242 1242  
1243 1243  * (((
1244 -[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
1255 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1245 1245  )))
1246 1246  * (((
1247 1247  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1248 1248  )))
1249 1249  * (((
1250 -[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
1261 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1251 1251  )))
1252 1252  
1253 1253  [[image:image-20220607172042-11.png]]
... ... @@ -1298,7 +1298,7 @@
1298 1298  
1299 1299   [[image:1654593712276-618.png]]
1300 1300  
1301 -Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]].
1312 +Valid AT Command please check [[Configure Device>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]].
1302 1302  
1303 1303  
1304 1304  = 6. FAQ =
... ... @@ -1305,18 +1305,17 @@
1305 1305  
1306 1306  == 6.1 How to change the LoRa Frequency Bands/Region ==
1307 1307  
1308 -You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1319 +You can follow the instructions for [[how to upgrade image>>path:#H2.10200BFirmwareChangeLog]].
1309 1309  When downloading the images, choose the required image file for download. ​
1310 1310  
1311 1311  
1312 1312  = 7. Trouble Shooting =
1313 1313  
1314 -== 7.1 AT Commands input doesn't work ==
1325 +== 7.1 AT Commands input doesnt work ==
1315 1315  
1316 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1327 +In the case if user can see the console output but cant type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1317 1317  
1318 1318  
1319 -
1320 1320  = 8. Order Info =
1321 1321  
1322 1322  Part Number: (% style="color:blue" %)**LSPH01-XX**
... ... @@ -1333,10 +1333,6 @@
1333 1333  * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1334 1334  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1335 1335  
1336 -
1337 -
1338 -
1339 -
1340 1340  = 9. ​Packing Info =
1341 1341  
1342 1342  
... ... @@ -1351,10 +1351,6 @@
1351 1351  * Package Size / pcs : cm
1352 1352  * Weight / pcs : g
1353 1353  
1354 -
1355 -
1356 -
1357 -
1358 1358  = 10. ​Support =
1359 1359  
1360 1360  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
image-20220610105907-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -15.5 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0