<
From version < 88.1 >
edited by Xiaoling
on 2022/06/25 16:42
To version < 98.20 >
edited by Xiaoling
on 2022/10/27 14:00
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,74 +4,23 @@
4 4  
5 5  
6 6  
7 +
7 7  **Table of Contents:**
8 8  
9 -* [[1. Introduction>>path:#H1.Introduction]]
10 -** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 -** [[​1.2 Features>>path:#H200B1.2Features]]
12 -** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 -** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 -** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 -* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 -** [[2.1 How it works>>path:#H2.1Howitworks]]
17 -** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 -** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 -*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 -*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 -*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 -*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 -*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 -*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 -*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 -** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 -** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 -** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 -*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 -*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 -*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 -** [[2.7 Calibration>>path:#H2.7Calibration]]
33 -** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 -*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 -*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 -*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 -*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 -*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 -*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 -*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 -** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 -** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 -* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 -** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 -** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 -** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 -** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 -* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 -** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 -** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 -** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 -*** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 -*** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 -* [[5. Use AT Command>>path:#H5.UseATCommand]]
55 -** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 -* [[6. FAQ>>path:#H6.FAQ]]
57 -** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 -* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 -** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 -* [[8. Order Info>>path:#H8.OrderInfo]]
61 -* [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 -* [[10. ​Support>>path:#H10.A0200BSupport]]
10 +{{toc/}}
63 63  
64 64  
65 65  
66 66  
67 67  
16 +
68 68  = 1. Introduction =
69 69  
19 +
70 70  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
71 71  
72 -(((
73 -
74 74  
23 +(((
75 75  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
76 76  )))
77 77  
... ... @@ -96,9 +96,9 @@
96 96  
97 97  
98 98  
99 -
100 100  == ​1.2 Features ==
101 101  
50 +
102 102  * LoRaWAN 1.0.3 Class A
103 103  * Ultra-low power consumption
104 104  * Monitor soil pH with temperature compensation.
... ... @@ -114,6 +114,7 @@
114 114  * 8500mAh Battery for long term use
115 115  
116 116  
66 +
117 117  == 1.3 Probe Specification ==
118 118  
119 119  
... ... @@ -135,13 +135,16 @@
135 135  * Length: 3.5 meters
136 136  
137 137  
88 +
138 138  == 1.4 ​Applications ==
139 139  
91 +
140 140  * Smart Agriculture
141 141  
142 142  
143 143  == 1.5 Pin mapping and power on ==
144 144  
97 +
145 145  [[image:1654592472094-134.png]]
146 146  
147 147  
... ... @@ -148,19 +148,23 @@
148 148  
149 149  = 2. Configure LSPH01 to connect to LoRaWAN network =
150 150  
104 +
151 151  == 2.1 How it works ==
152 152  
107 +
153 153  (((
154 154  The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
155 155  )))
156 156  
157 157  (((
158 -In case you cant set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
113 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
159 159  )))
160 160  
161 161  
117 +
162 162  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
163 163  
120 +
164 164  (((
165 165  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
166 166  )))
... ... @@ -226,6 +226,8 @@
226 226  
227 227  (((
228 228  (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
186 +
187 +
229 229  )))
230 230  
231 231  [[image:1654592697690-910.png]]
... ... @@ -234,6 +234,7 @@
234 234  
235 235  == 2.3 ​Uplink Payload ==
236 236  
196 +
237 237  (((
238 238  LSPH01 will uplink payload via LoRaWAN with below payload format: 
239 239  )))
... ... @@ -246,14 +246,11 @@
246 246  Normal uplink payload:
247 247  )))
248 248  
249 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
250 -|=(% style="width: 62.5px;" %)(((
251 -**Size (bytes)**
252 -)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1**
209 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:470px" %)
210 +|=(% style="width: 60px;" %)(((
211 +**Size (bytes)**)))|=(% style="width: 30px;" %)**2**|=(% style="width: 70px;" %)**2**|=(% style="width: 50px;" %)**2**|=(% style="width: 60px;" %)**2**|=(% style="width: 70px;" %)**1**|=(% style="width: 50px;" %)**1**|=(% style="width: 80px;" %)**1**
253 253  |(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)(((
254 -[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
255 -
256 -[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
213 +[[Temperature (Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
257 257  )))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
258 258  [[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
259 259  )))|Reserve|(((
... ... @@ -277,6 +277,7 @@
277 277  
278 278  === 2.3.2 DS18B20 Temperature sensor ===
279 279  
237 +
280 280  This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
281 281  
282 282  
... ... @@ -290,6 +290,7 @@
290 290  
291 291  === 2.3.3 Soil pH ===
292 292  
251 +
293 293  Range: 0 ~~ 14 pH
294 294  
295 295  **Example:**
... ... @@ -300,6 +300,7 @@
300 300  
301 301  === 2.3.4 Soil Temperature ===
302 302  
262 +
303 303  Get Soil Temperature 
304 304  
305 305  
... ... @@ -313,6 +313,7 @@
313 313  
314 314  === 2.3.5 Interrupt Pin ===
315 315  
276 +
316 316  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
317 317  
318 318  
... ... @@ -326,6 +326,7 @@
326 326  
327 327  === 2.3.6 Message Type ===
328 328  
290 +
329 329  (((
330 330  For a normal uplink payload, the message type is always 0x01.
331 331  )))
... ... @@ -335,7 +335,7 @@
335 335  )))
336 336  
337 337  
338 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:499px" %)
300 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:496px" %)
339 339  |=(% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload**
340 340  |(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
341 341  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
... ... @@ -342,6 +342,7 @@
342 342  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
343 343  
344 344  
307 +
345 345  === 2.3.7 Decode payload in The Things Network ===
346 346  
347 347  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -354,7 +354,7 @@
354 354  )))
355 355  
356 356  (((
357 -LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
320 +LSPH01 TTN Payload Decoder:  [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
358 358  )))
359 359  
360 360  
... ... @@ -361,6 +361,7 @@
361 361  
362 362  == 2.4 Uplink Interval ==
363 363  
327 +
364 364  The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
365 365  
366 366  
... ... @@ -367,6 +367,7 @@
367 367  
368 368  == 2.5 ​Show Data in DataCake IoT Server ==
369 369  
334 +
370 370  (((
371 371  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
372 372  )))
... ... @@ -409,7 +409,7 @@
409 409  )))
410 410  
411 411  (((
412 -Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
377 +Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
413 413  )))
414 414  
415 415  
... ... @@ -430,8 +430,10 @@
430 430  
431 431  == 2.6 Installation and Maintain ==
432 432  
398 +
433 433  === 2.6.1 Before measurement ===
434 434  
401 +
435 435  (((
436 436  (((
437 437  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
... ... @@ -449,6 +449,8 @@
449 449  
450 450  (((
451 451  [[image:1654592946732-634.png]]
419 +
420 +
452 452  )))
453 453  
454 454  (((
... ... @@ -460,7 +460,7 @@
460 460  )))
461 461  
462 462  (((
463 -Slowly insert the probe to the measure point. Dont use large force which will break the probe. Make sure not shake when inserting.
432 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting.
464 464  )))
465 465  
466 466  (((
... ... @@ -487,6 +487,7 @@
487 487  
488 488  === 2.6.3 Maintain Probe ===
489 489  
459 +
490 490  1. (((
491 491  pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
492 492  )))
... ... @@ -511,6 +511,7 @@
511 511  
512 512  == 2.7 Calibration ==
513 513  
484 +
514 514  (((
515 515  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
516 516  )))
... ... @@ -524,21 +524,16 @@
524 524  
525 525  (% style="color:#037691" %)**Calibration Payload**
526 526  
527 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
528 -|=(% style="width: 62.5px;" %)(((
498 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:500px" %)
499 +|=(% style="width: 60px;" %)(((
529 529  **Size (bytes)**
530 -)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1**
501 +)))|=(% style="width: 100px;" %)**1**|=(% style="width: 100px;" %)**1**|=(% style="width: 100px;" %)**1**|=(% style="width: 50px;" %)**7**|=(% style="width: 90px;" %)**1**
531 531  |**Value**|(((
532 -PH4
533 -
534 -Calibrate value
503 +PH4 Calibrate value
535 535  )))|PH6.86 Calibrate value|(((
536 -PH9.18
537 -
538 -Calibrate value
505 +PH9.18 Calibrate value
539 539  )))|Reserve|(((
540 540  [[Message Type>>||anchor="H2.3.6MessageType"]]
541 -
542 542  Always 0x03
543 543  )))
544 544  
... ... @@ -551,19 +551,18 @@
551 551  * Reply to non-confirmed packet: 14 00
552 552  
553 553  
554 -
555 -
556 -
557 -
558 558  == 2.8 Frequency Plans ==
559 559  
522 +
560 560  (((
561 561  The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
562 562  )))
563 563  
564 564  
528 +
565 565  === 2.8.1 EU863-870 (EU868) ===
566 566  
531 +
567 567  (((
568 568  (% style="color:blue" %)**Uplink:**
569 569  )))
... ... @@ -624,6 +624,7 @@
624 624  
625 625  === 2.8.2 US902-928(US915) ===
626 626  
592 +
627 627  (((
628 628  Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
629 629  )))
... ... @@ -637,15 +637,13 @@
637 637  )))
638 638  
639 639  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
640 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
606 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
641 641  
642 642  
643 643  
644 -
645 -
646 -
647 647  === 2.8.3 CN470-510 (CN470) ===
648 648  
612 +
649 649  (((
650 650  Used in China, Default use CHE=1
651 651  )))
... ... @@ -734,6 +734,7 @@
734 734  
735 735  === 2.8.4 AU915-928(AU915) ===
736 736  
701 +
737 737  (((
738 738  Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
739 739  )))
... ... @@ -751,11 +751,13 @@
751 751  )))
752 752  
753 753  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
754 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
719 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
755 755  
756 756  
722 +
757 757  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
758 758  
725 +
759 759  (((
760 760  (% style="color:blue" %)**Default Uplink channel:**
761 761  )))
... ... @@ -864,6 +864,7 @@
864 864  
865 865  === 2.8.6 KR920-923 (KR920) ===
866 866  
834 +
867 867  (((
868 868  (% style="color:blue" %)**Default channel:**
869 869  )))
... ... @@ -936,6 +936,7 @@
936 936  
937 937  === 2.8.7 IN865-867 (IN865) ===
938 938  
907 +
939 939  (((
940 940  (% style="color:blue" %)**Uplink:**
941 941  )))
... ... @@ -972,6 +972,7 @@
972 972  
973 973  == 2.9 LED Indicator ==
974 974  
944 +
975 975  The LSPH01 has an internal LED which is to show the status of different state.
976 976  
977 977  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
... ... @@ -978,14 +978,13 @@
978 978  * Blink once when device transmit a packet.
979 979  
980 980  
951 +
981 981  == 2.10 ​Firmware Change Log ==
982 982  
983 983  
984 -**Firmware download link:**
955 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]]
985 985  
986 -[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
987 987  
988 -
989 989  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
990 990  
991 991  
... ... @@ -992,6 +992,7 @@
992 992  
993 993  = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
994 994  
964 +
995 995  (((
996 996  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
997 997  )))
... ... @@ -1023,7 +1023,7 @@
1023 1023  )))
1024 1024  
1025 1025  (((
1026 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
996 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1027 1027  )))
1028 1028  
1029 1029  (((
... ... @@ -1042,6 +1042,7 @@
1042 1042  
1043 1043  == 3.1 Set Transmit Interval Time ==
1044 1044  
1015 +
1045 1045  Feature: Change LoRaWAN End Node Transmit Interval.
1046 1046  
1047 1047  (% style="color:#037691" %)**AT Command: AT+TDC**
... ... @@ -1068,11 +1068,13 @@
1068 1068  Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1069 1069  
1070 1070  
1042 +
1071 1071  
1072 1072  )))
1073 1073  
1074 1074  == 3.2 Set Interrupt Mode ==
1075 1075  
1048 +
1076 1076  Feature, Set Interrupt mode for GPIO_EXIT.
1077 1077  
1078 1078  (% style="color:#037691" %)**AT Command: AT+INTMOD**
... ... @@ -1107,6 +1107,7 @@
1107 1107  
1108 1108  == 3.3 Calibrate Sensor ==
1109 1109  
1083 +
1110 1110  Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
1111 1111  
1112 1112  
... ... @@ -1113,6 +1113,7 @@
1113 1113  
1114 1114  == 3.4 Get Firmware Version Info ==
1115 1115  
1090 +
1116 1116  Feature: use downlink to get firmware version.
1117 1117  
1118 1118  (% style="color:#037691" %)**Downlink Command: 0x26**
... ... @@ -1143,10 +1143,10 @@
1143 1143  Always 0x02
1144 1144  )))
1145 1145  
1146 -**Software Type**: Always 0x03 for LSPH01
1121 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01
1147 1147  
1148 1148  
1149 -**Frequency Band**:
1124 +(% style="color:#037691" %)**Frequency Band**:
1150 1150  
1151 1151  *0x01: EU868
1152 1152  
... ... @@ -1169,13 +1169,13 @@
1169 1169  *0xa0: AS923-3
1170 1170  
1171 1171  
1172 -**Sub-Band**: value 0x00 ~~ 0x08
1147 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08
1173 1173  
1174 1174  
1175 -**Firmware Version**: 0x0100, Means: v1.0.0 version
1150 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
1176 1176  
1177 1177  
1178 -**Sensor Type**:
1153 +(% style="color:#037691" %)**Sensor Type**:
1179 1179  
1180 1180  0x01: LSE01
1181 1181  
... ... @@ -1195,14 +1195,18 @@
1195 1195  
1196 1196  = 4. Battery & How to replace =
1197 1197  
1173 +
1198 1198  == 4.1 Battery Type ==
1199 1199  
1176 +
1200 1200  (((
1201 1201  LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1202 1202  )))
1203 1203  
1204 1204  (((
1205 -The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
1182 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1183 +
1184 +
1206 1206  )))
1207 1207  
1208 1208  [[image:1654593587246-335.png]]
... ... @@ -1216,6 +1216,7 @@
1216 1216  
1217 1217  == 4.2 Replace Battery ==
1218 1218  
1198 +
1219 1219  (((
1220 1220  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
1221 1221  )))
... ... @@ -1228,6 +1228,7 @@
1228 1228  
1229 1229  == 4.3 Power Consumption Analyze ==
1230 1230  
1211 +
1231 1231  (((
1232 1232  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
1233 1233  )))
... ... @@ -1237,12 +1237,12 @@
1237 1237  )))
1238 1238  
1239 1239  
1240 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1221 +(% style="color:#037691" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1241 1241  
1242 1242  [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1243 1243  
1244 1244  
1245 -**Step 2**: Open it and choose
1226 +(% style="color:#037691" %)**Step 2**(%%): Open it and choose
1246 1246  
1247 1247  * Product Model
1248 1248  * Uplink Interval
... ... @@ -1256,13 +1256,13 @@
1256 1256  The battery related documents as below:
1257 1257  
1258 1258  * (((
1259 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1240 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
1260 1260  )))
1261 1261  * (((
1262 1262  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1263 1263  )))
1264 1264  * (((
1265 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1246 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
1266 1266  )))
1267 1267  
1268 1268  [[image:image-20220607172042-11.png]]
... ... @@ -1271,6 +1271,7 @@
1271 1271  
1272 1272  === 4.3.1 ​Battery Note ===
1273 1273  
1255 +
1274 1274  (((
1275 1275  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
1276 1276  )))
... ... @@ -1279,12 +1279,13 @@
1279 1279  
1280 1280  === ​4.3.2 Replace the battery ===
1281 1281  
1264 +
1282 1282  (((
1283 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there wont be voltage drop between battery and main board.
1266 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
1284 1284  )))
1285 1285  
1286 1286  (((
1287 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user cant find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1270 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1288 1288  )))
1289 1289  
1290 1290  
... ... @@ -1291,12 +1291,16 @@
1291 1291  
1292 1292  = 5. Use AT Command =
1293 1293  
1277 +
1294 1294  == 5.1 Access AT Commands ==
1295 1295  
1280 +
1296 1296  LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
1297 1297  
1283 +
1298 1298  [[image:1654593668970-604.png]]
1299 1299  
1286 +
1300 1300  **Connection:**
1301 1301  
1302 1302  (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
... ... @@ -1318,22 +1318,28 @@
1318 1318  
1319 1319  = 6. FAQ =
1320 1320  
1308 +
1321 1321  == 6.1 How to change the LoRa Frequency Bands/Region ==
1322 1322  
1311 +
1323 1323  You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1324 1324  When downloading the images, choose the required image file for download. ​
1325 1325  
1326 1326  
1316 +
1327 1327  = 7. Trouble Shooting =
1328 1328  
1329 -== 7.1 AT Commands input doesn’t work ==
1330 1330  
1331 -In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1320 +== 7.1 AT Commands input doesn't work ==
1332 1332  
1333 1333  
1323 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1334 1334  
1325 +
1326 +
1335 1335  = 8. Order Info =
1336 1336  
1329 +
1337 1337  Part Number: (% style="color:blue" %)**LSPH01-XX**
1338 1338  
1339 1339  
... ... @@ -1348,6 +1348,7 @@
1348 1348  * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1349 1349  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1350 1350  
1344 +
1351 1351  = 9. ​Packing Info =
1352 1352  
1353 1353  
... ... @@ -1362,8 +1362,10 @@
1362 1362  * Package Size / pcs : cm
1363 1363  * Weight / pcs : g
1364 1364  
1359 +
1365 1365  = 10. ​Support =
1366 1366  
1362 +
1367 1367  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1368 1368  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
1369 1369  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0