From version < 87.2 >
edited by Xiaoling
on 2022/06/14 14:38
To version < 90.8 >
edited by Xiaoling
on 2022/06/25 16:57
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -61,11 +61,6 @@
61 61  * [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 62  * [[10. ​Support>>path:#H10.A0200BSupport]]
63 63  
64 -
65 -
66 -
67 -
68 -
69 69  = 1. Introduction =
70 70  
71 71  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
... ... @@ -114,8 +114,6 @@
114 114  * IP68 rate for the Sensor Probe
115 115  * 8500mAh Battery for long term use
116 116  
117 -
118 -
119 119  == 1.3 Probe Specification ==
120 120  
121 121  
... ... @@ -136,14 +136,10 @@
136 136  * IP68 Protection
137 137  * Length: 3.5 meters
138 138  
139 -
140 -
141 141  == 1.4 ​Applications ==
142 142  
143 143  * Smart Agriculture
144 144  
145 -
146 -
147 147  == 1.5 Pin mapping and power on ==
148 148  
149 149  [[image:1654592472094-134.png]]
... ... @@ -347,6 +347,9 @@
347 347  
348 348  
349 349  
339 +
340 +
341 +
350 350  === 2.3.7 Decode payload in The Things Network ===
351 351  
352 352  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -641,6 +641,10 @@
641 641  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
642 642  
643 643  
636 +
637 +
638 +
639 +
644 644  === 2.8.3 CN470-510 (CN470) ===
645 645  
646 646  (((
... ... @@ -752,6 +752,9 @@
752 752  
753 753  
754 754  
751 +
752 +
753 +
755 755  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
756 756  
757 757  (((
... ... @@ -977,6 +977,9 @@
977 977  
978 978  
979 979  
979 +
980 +
981 +
980 980  == 2.10 ​Firmware Change Log ==
981 981  
982 982  
... ... @@ -1048,7 +1048,6 @@
1048 1048  [[image:image-20220607171554-8.png]]
1049 1049  
1050 1050  
1051 -
1052 1052  (((
1053 1053  (% style="color:#037691" %)**Downlink Command: 0x01**
1054 1054  )))
... ... @@ -1143,10 +1143,10 @@
1143 1143  Always 0x02
1144 1144  )))
1145 1145  
1146 -**Software Type**: Always 0x03 for LSPH01
1147 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01
1147 1147  
1148 1148  
1149 -**Frequency Band**:
1150 +(% style="color:#037691" %)**Frequency Band**:
1150 1150  
1151 1151  *0x01: EU868
1152 1152  
... ... @@ -1169,13 +1169,13 @@
1169 1169  *0xa0: AS923-3
1170 1170  
1171 1171  
1172 -**Sub-Band**: value 0x00 ~~ 0x08
1173 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08
1173 1173  
1174 1174  
1175 -**Firmware Version**: 0x0100, Means: v1.0.0 version
1176 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
1176 1176  
1177 1177  
1178 -**Sensor Type**:
1179 +(% style="color:#037691" %)**Sensor Type**:
1179 1179  
1180 1180  0x01: LSE01
1181 1181  
... ... @@ -1202,7 +1202,7 @@
1202 1202  )))
1203 1203  
1204 1204  (((
1205 -The discharge curve is not linear so cant simply use percentage to show the battery level. Below is the battery performance.
1206 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1206 1206  )))
1207 1207  
1208 1208  [[image:1654593587246-335.png]]
... ... @@ -1237,12 +1237,12 @@
1237 1237  )))
1238 1238  
1239 1239  
1240 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1241 +(% style="color:red" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1241 1241  
1242 1242  [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1243 1243  
1244 1244  
1245 -**Step 2**: Open it and choose
1246 +(% style="color:#037691" %)**Step 2**(%%): Open it and choose
1246 1246  
1247 1247  * Product Model
1248 1248  * Uplink Interval
... ... @@ -1256,13 +1256,13 @@
1256 1256  The battery related documents as below:
1257 1257  
1258 1258  * (((
1259 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1260 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
1260 1260  )))
1261 1261  * (((
1262 1262  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1263 1263  )))
1264 1264  * (((
1265 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1266 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
1266 1266  )))
1267 1267  
1268 1268  [[image:image-20220607172042-11.png]]
... ... @@ -1280,7 +1280,7 @@
1280 1280  === ​4.3.2 Replace the battery ===
1281 1281  
1282 1282  (((
1283 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there wont be voltage drop between battery and main board.
1284 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
1284 1284  )))
1285 1285  
1286 1286  (((
... ... @@ -1326,9 +1326,9 @@
1326 1326  
1327 1327  = 7. Trouble Shooting =
1328 1328  
1329 -== 7.1 AT Commands input doesnt work ==
1330 +== 7.1 AT Commands input doesn't work ==
1330 1330  
1331 -In the case if user can see the console output but cant type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1332 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1332 1332  
1333 1333  
1334 1334  
... ... @@ -1349,6 +1349,8 @@
1349 1349  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1350 1350  
1351 1351  
1353 +
1354 +
1352 1352  = 9. ​Packing Info =
1353 1353  
1354 1354  
... ... @@ -1364,6 +1364,8 @@
1364 1364  * Weight / pcs : g
1365 1365  
1366 1366  
1370 +
1371 +
1367 1367  = 10. ​Support =
1368 1368  
1369 1369  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0