7 7  **Table of Contents:**
8 8  
9 -* [[1. Introduction>>path:#H1.Introduction]]
10 -** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 -** [[​1.2 Features>>path:#H200B1.2Features]]
12 -** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 -** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 -** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 -* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 -** [[2.1 How it works>>path:#H2.1Howitworks]]
17 -** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 -** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 -*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 -*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 -*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 -*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 -*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 -*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 -*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 -** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 -** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 -** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 -*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 -*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 -*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 -** [[2.7 Calibration>>path:#H2.7Calibration]]
33 -** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 -*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 -*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 -*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 -*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 -*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 -*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 -*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 -** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 -** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 -* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 -** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 -** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 -** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 -** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 -* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 -** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 -** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 -** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 -*** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 -*** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 -* [[5. Use AT Command>>path:#H5.UseATCommand]]
55 -** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 -* [[6. FAQ>>path:#H6.FAQ]]
57 -** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 -* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 -** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 -* [[8. Order Info>>path:#H8.OrderInfo]]
61 -* [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 -* [[10. ​Support>>path:#H10.A0200BSupport]]
10 +{{toc/}}
63 63  
64 64  
65 65  
66 66  
15 +
16 +
67 67  = 1. Introduction =
68 68  
19 +
69 69  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
70 70  
71 -(((
72 -
73 73  
23 +(((
74 74  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
75 75  )))
76 76  
... ... @@ -95,9 +95,9 @@
95 95  
96 96  
97 97  
98 -
99 99  == ​1.2 Features ==
100 100  
50 +
101 101  * LoRaWAN 1.0.3 Class A
102 102  * Ultra-low power consumption
103 103  * Monitor soil pH with temperature compensation.
... ... @@ -114,7 +114,6 @@
114 114  
115 115  
116 116  
117 -
118 118  == 1.3 Probe Specification ==
119 119  
120 120  
... ... @@ -127,7 +127,6 @@
127 127  * IP68 Protection
128 128  * Length: 3.5 meters
129 129  
130 -
131 131  (% style="color:#4f81bd" %)**Soil Temperature:**
132 132  
133 133  * Range -40℃~85℃
... ... @@ -138,16 +138,15 @@
138 138  
139 139  
140 140  
141 -
142 142  == 1.4 ​Applications ==
143 143  
91 +
144 144  * Smart Agriculture
145 145  
146 146  
147 -
148 -
149 149  == 1.5 Pin mapping and power on ==
150 150  
97 +
151 151  [[image:1654592472094-134.png]]
152 152  
153 153  
... ... @@ -154,19 +154,23 @@
154 154  
155 155  = 2. Configure LSPH01 to connect to LoRaWAN network =
156 156  
104 +
157 157  == 2.1 How it works ==
158 158  
107 +
159 159  (((
160 160  The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
161 161  )))
162 162  
163 163  (((
164 -In case you cant set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
113 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
165 165  )))
166 166  
167 167  
117 +
168 168  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
169 169  
120 +
170 170  (((
171 171  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
172 172  )))
... ... @@ -232,6 +232,8 @@
232 232  
233 233  (((
234 234  (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
186 +
187 +
235 235  )))
236 236  
237 237  [[image:1654592697690-910.png]]
... ... @@ -240,6 +240,7 @@
240 240  
241 241  == 2.3 ​Uplink Payload ==
242 242  
196 +
243 243  (((
244 244  LSPH01 will uplink payload via LoRaWAN with below payload format: 
245 245  )))
... ... @@ -252,14 +252,11 @@
252 252  Normal uplink payload:
253 253  )))
254 254  
255 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
256 -|=(% style="width: 62.5px;" %)(((
257 -**Size (bytes)**
258 -)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1**
209 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:470px" %)
210 +|=(% style="width: 60px;" %)(((
211 +**Size (bytes)**)))|=(% style="width: 30px;" %)**2**|=(% style="width: 70px;" %)**2**|=(% style="width: 50px;" %)**2**|=(% style="width: 60px;" %)**2**|=(% style="width: 70px;" %)**1**|=(% style="width: 50px;" %)**1**|=(% style="width: 80px;" %)**1**
259 259  |(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)(((
260 -[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
261 -
262 -[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
213 +[[Temperature (Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
263 263  )))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
264 264  [[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
265 265  )))|Reserve|(((
... ... @@ -283,6 +283,7 @@
283 283  
284 284  === 2.3.2 DS18B20 Temperature sensor ===
285 285  
237 +
286 286  This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
287 287  
288 288  
... ... @@ -296,6 +296,7 @@
296 296  
297 297  === 2.3.3 Soil pH ===
298 298  
251 +
299 299  Range: 0 ~~ 14 pH
300 300  
301 301  **Example:**
... ... @@ -306,6 +306,7 @@
306 306  
307 307  === 2.3.4 Soil Temperature ===
308 308  
262 +
309 309  Get Soil Temperature 
310 310  
311 311  
... ... @@ -319,6 +319,7 @@
319 319  
320 320  === 2.3.5 Interrupt Pin ===
321 321  
276 +
322 322  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
323 323  
324 324  
... ... @@ -332,6 +332,7 @@
332 332  
333 333  === 2.3.6 Message Type ===
334 334  
290 +
335 335  (((
336 336  For a normal uplink payload, the message type is always 0x01.
337 337  )))
... ... @@ -349,7 +349,6 @@
349 349  
350 350  
351 351  
352 -
353 353  === 2.3.7 Decode payload in The Things Network ===
354 354  
355 355  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -362,7 +362,7 @@
362 362  )))
363 363  
364 364  (((
365 -LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
320 +LSPH01 TTN Payload Decoder:  [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
366 366  )))
367 367  
368 368  
... ... @@ -369,6 +369,7 @@
369 369  
370 370  == 2.4 Uplink Interval ==
371 371  
327 +
372 372  The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
373 373  
374 374  
... ... @@ -375,6 +375,7 @@
375 375  
376 376  == 2.5 ​Show Data in DataCake IoT Server ==
377 377  
334 +
378 378  (((
379 379  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
380 380  )))
... ... @@ -417,7 +417,7 @@
417 417  )))
418 418  
419 419  (((
420 -Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
377 +Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
421 421  )))
422 422  
423 423  
... ... @@ -438,8 +438,10 @@
438 438  
439 439  == 2.6 Installation and Maintain ==
440 440  
398 +
441 441  === 2.6.1 Before measurement ===
442 442  
401 +
443 443  (((
444 444  (((
445 445  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
... ... @@ -457,6 +457,8 @@
457 457  
458 458  (((
459 459  [[image:1654592946732-634.png]]
419 +
420 +
460 460  )))
461 461  
462 462  (((
... ... @@ -468,7 +468,7 @@
468 468  )))
469 469  
470 470  (((
471 -Slowly insert the probe to the measure point. Dont use large force which will break the probe. Make sure not shake when inserting.
432 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting.
472 472  )))
473 473  
474 474  (((
... ... @@ -495,6 +495,7 @@
495 495  
496 496  === 2.6.3 Maintain Probe ===
497 497  
459 +
498 498  1. (((
499 499  pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
500 500  )))
... ... @@ -519,6 +519,7 @@
519 519  
520 520  == 2.7 Calibration ==
521 521  
484 +
522 522  (((
523 523  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
524 524  )))
... ... @@ -559,16 +559,18 @@
559 559  * Reply to non-confirmed packet: 14 00
560 560  
561 561  
562 -
563 563  == 2.8 Frequency Plans ==
564 564  
527 +
565 565  (((
566 566  The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
567 567  )))
568 568  
569 569  
533 +
570 570  === 2.8.1 EU863-870 (EU868) ===
571 571  
536 +
572 572  (((
573 573  (% style="color:blue" %)**Uplink:**
574 574  )))
... ... @@ -629,6 +629,7 @@
629 629  
630 630  === 2.8.2 US902-928(US915) ===
631 631  
597 +
632 632  (((
633 633  Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
634 634  )))
... ... @@ -642,12 +642,13 @@
642 642  )))
643 643  
644 644  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
645 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
611 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
646 646  
647 647  
648 648  
649 649  === 2.8.3 CN470-510 (CN470) ===
650 650  
617 +
651 651  (((
652 652  Used in China, Default use CHE=1
653 653  )))
... ... @@ -736,6 +736,7 @@
736 736  
737 737  === 2.8.4 AU915-928(AU915) ===
738 738  
706 +
739 739  (((
740 740  Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
741 741  )))
... ... @@ -753,13 +753,13 @@
753 753  )))
754 754  
755 755  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
756 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
724 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
757 757  
758 758  
759 759  
760 -
761 761  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
762 762  
730 +
763 763  (((
764 764  (% style="color:blue" %)**Default Uplink channel:**
765 765  )))
... ... @@ -868,6 +868,7 @@
868 868  
869 869  === 2.8.6 KR920-923 (KR920) ===
870 870  
839 +
871 871  (((
872 872  (% style="color:blue" %)**Default channel:**
873 873  )))
... ... @@ -940,6 +940,7 @@
940 940  
941 941  === 2.8.7 IN865-867 (IN865) ===
942 942  
912 +
943 943  (((
944 944  (% style="color:blue" %)**Uplink:**
945 945  )))
... ... @@ -976,6 +976,7 @@
976 976  
977 977  == 2.9 LED Indicator ==
978 978  
949 +
979 979  The LSPH01 has an internal LED which is to show the status of different state.
980 980  
981 981  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
... ... @@ -983,15 +983,12 @@
983 983  
984 984  
985 985  
986 -
987 987  == 2.10 ​Firmware Change Log ==
988 988  
989 989  
990 -**Firmware download link:**
960 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]]
991 991  
992 -[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
993 993  
994 -
995 995  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
996 996  
997 997  
... ... @@ -998,6 +998,7 @@
998 998  
999 999  = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
1000 1000  
969 +
1001 1001  (((
1002 1002  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
1003 1003  )))
... ... @@ -1029,7 +1029,7 @@
1029 1029  )))
1030 1030  
1031 1031  (((
1032 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1001 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1033 1033  )))
1034 1034  
1035 1035  (((
... ... @@ -1048,6 +1048,7 @@
1048 1048  
1049 1049  == 3.1 Set Transmit Interval Time ==
1050 1050  
1020 +
1051 1051  Feature: Change LoRaWAN End Node Transmit Interval.
1052 1052  
1053 1053  (% style="color:#037691" %)**AT Command: AT+TDC**
... ... @@ -1055,7 +1055,6 @@
1055 1055  [[image:image-20220607171554-8.png]]
1056 1056  
1057 1057  
1058 -
1059 1059  (((
1060 1060  (% style="color:#037691" %)**Downlink Command: 0x01**
1061 1061  )))
... ... @@ -1075,11 +1075,13 @@
1075 1075  Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1076 1076  
1077 1077  
1047 +
1078 1078  
1079 1079  )))
1080 1080  
1081 1081  == 3.2 Set Interrupt Mode ==
1082 1082  
1053 +
1083 1083  Feature, Set Interrupt mode for GPIO_EXIT.
1084 1084  
1085 1085  (% style="color:#037691" %)**AT Command: AT+INTMOD**
... ... @@ -1114,6 +1114,7 @@
1114 1114  
1115 1115  == 3.3 Calibrate Sensor ==
1116 1116  
1088 +
1117 1117  Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
1118 1118  
1119 1119  
... ... @@ -1120,6 +1120,7 @@
1120 1120  
1121 1121  == 3.4 Get Firmware Version Info ==
1122 1122  
1095 +
1123 1123  Feature: use downlink to get firmware version.
1124 1124  
1125 1125  (% style="color:#037691" %)**Downlink Command: 0x26**
... ... @@ -1150,10 +1150,10 @@
1150 1150  Always 0x02
1151 1151  )))
1152 1152  
1153 -**Software Type**: Always 0x03 for LSPH01
1126 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01
1154 1154  
1155 1155  
1156 -**Frequency Band**:
1129 +(% style="color:#037691" %)**Frequency Band**:
1157 1157  
1158 1158  *0x01: EU868
1159 1159  
... ... @@ -1176,13 +1176,13 @@
1176 1176  *0xa0: AS923-3
1177 1177  
1178 1178  
1179 -**Sub-Band**: value 0x00 ~~ 0x08
1152 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08
1180 1180  
1181 1181  
1182 -**Firmware Version**: 0x0100, Means: v1.0.0 version
1155 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
1183 1183  
1184 1184  
1185 -**Sensor Type**:
1158 +(% style="color:#037691" %)**Sensor Type**:
1186 1186  
1187 1187  0x01: LSE01
1188 1188  
... ... @@ -1202,14 +1202,18 @@
1202 1202  
1203 1203  = 4. Battery & How to replace =
1204 1204  
1178 +
1205 1205  == 4.1 Battery Type ==
1206 1206  
1181 +
1207 1207  (((
1208 1208  LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1209 1209  )))
1210 1210  
1211 1211  (((
1212 -The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
1187 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1188 +
1189 +
1213 1213  )))
1214 1214  
1215 1215  [[image:1654593587246-335.png]]
... ... @@ -1223,6 +1223,7 @@
1223 1223  
1224 1224  == 4.2 Replace Battery ==
1225 1225  
1203 +
1226 1226  (((
1227 1227  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
1228 1228  )))
... ... @@ -1235,6 +1235,7 @@
1235 1235  
1236 1236  == 4.3 Power Consumption Analyze ==
1237 1237  
1216 +
1238 1238  (((
1239 1239  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
1240 1240  )))
... ... @@ -1244,12 +1244,12 @@
1244 1244  )))
1245 1245  
1246 1246  
1247 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1226 +(% style="color:#037691" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1248 1248  
1249 1249  [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1250 1250  
1251 1251  
1252 -**Step 2**: Open it and choose
1231 +(% style="color:#037691" %)**Step 2**(%%): Open it and choose
1253 1253  
1254 1254  * Product Model
1255 1255  * Uplink Interval
... ... @@ -1263,13 +1263,13 @@
1263 1263  The battery related documents as below:
1264 1264  
1265 1265  * (((
1266 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1245 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
1267 1267  )))
1268 1268  * (((
1269 1269  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1270 1270  )))
1271 1271  * (((
1272 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1251 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
1273 1273  )))
1274 1274  
1275 1275  [[image:image-20220607172042-11.png]]
... ... @@ -1278,6 +1278,7 @@
1278 1278  
1279 1279  === 4.3.1 ​Battery Note ===
1280 1280  
1260 +
1281 1281  (((
1282 1282  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
1283 1283  )))
... ... @@ -1286,12 +1286,13 @@
1286 1286  
1287 1287  === ​4.3.2 Replace the battery ===
1288 1288  
1269 +
1289 1289  (((
1290 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there wont be voltage drop between battery and main board.
1271 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
1291 1291  )))
1292 1292  
1293 1293  (((
1294 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user cant find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1275 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1295 1295  )))
1296 1296  
1297 1297  
... ... @@ -1298,12 +1298,16 @@
1298 1298  
1299 1299  = 5. Use AT Command =
1300 1300  
1282 +
1301 1301  == 5.1 Access AT Commands ==
1302 1302  
1285 +
1303 1303  LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
1304 1304  
1288 +
1305 1305  [[image:1654593668970-604.png]]
1306 1306  
1291 +
1307 1307  **Connection:**
1308 1308  
1309 1309  (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
... ... @@ -1325,22 +1325,28 @@
1325 1325  
1326 1326  = 6. FAQ =
1327 1327  
1313 +
1328 1328  == 6.1 How to change the LoRa Frequency Bands/Region ==
1329 1329  
1316 +
1330 1330  You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1331 1331  When downloading the images, choose the required image file for download. ​
1332 1332  
1333 1333  
1321 +
1334 1334  = 7. Trouble Shooting =
1335 1335  
1336 -== 7.1 AT Commands input doesn’t work ==
1337 1337  
1338 -In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1325 +== 7.1 AT Commands input doesn't work ==
1339 1339  
1340 1340  
1328 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1341 1341  
1330 +
1331 +
1342 1342  = 8. Order Info =
1343 1343  
1334 +
1344 1344  Part Number: (% style="color:blue" %)**LSPH01-XX**
1345 1345  
1346 1346  
... ... @@ -1356,7 +1356,6 @@
1356 1356  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1357 1357  
1358 1358  
1359 -
1360 1360  = 9. ​Packing Info =
1361 1361  
1362 1362  
... ... @@ -1372,9 +1372,9 @@
1372 1372  * Weight / pcs : g
1373 1373  
1374 1374  
1375 -
1376 1376  = 10. ​Support =
1377 1377  
1367 +
1378 1378  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1379 1379  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
1380 1380  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0