<
From version < 86.7 >
edited by Xiaoling
on 2022/06/14 14:33
To version < 90.2 >
edited by Xiaoling
on 2022/06/25 16:48
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -62,8 +62,6 @@
62 62  * [[10. ​Support>>path:#H10.A0200BSupport]]
63 63  
64 64  
65 -
66 -
67 67  = 1. Introduction =
68 68  
69 69  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
... ... @@ -112,9 +112,6 @@
112 112  * IP68 rate for the Sensor Probe
113 113  * 8500mAh Battery for long term use
114 114  
115 -
116 -
117 -
118 118  == 1.3 Probe Specification ==
119 119  
120 120  
... ... @@ -127,7 +127,6 @@
127 127  * IP68 Protection
128 128  * Length: 3.5 meters
129 129  
130 -
131 131  (% style="color:#4f81bd" %)**Soil Temperature:**
132 132  
133 133  * Range -40℃~85℃
... ... @@ -136,16 +136,10 @@
136 136  * IP68 Protection
137 137  * Length: 3.5 meters
138 138  
139 -
140 -
141 -
142 142  == 1.4 ​Applications ==
143 143  
144 144  * Smart Agriculture
145 145  
146 -
147 -
148 -
149 149  == 1.5 Pin mapping and power on ==
150 150  
151 151  [[image:1654592472094-134.png]]
... ... @@ -204,11 +204,13 @@
204 204  [[image:1654592600093-601.png]]
205 205  
206 206  
195 +
207 207  **Add APP EUI and DEV EUI**
208 208  
209 209  [[image:1654592619856-881.png]]
210 210  
211 211  
201 +
212 212  **Add APP EUI in the application**
213 213  
214 214  [[image:1654592632656-512.png]]
... ... @@ -554,6 +554,7 @@
554 554  * Reply to non-confirmed packet: 14 00
555 555  
556 556  
547 +
557 557  == 2.8 Frequency Plans ==
558 558  
559 559  (((
... ... @@ -639,6 +639,7 @@
639 639  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
640 640  
641 641  
633 +
642 642  === 2.8.3 CN470-510 (CN470) ===
643 643  
644 644  (((
... ... @@ -1042,7 +1042,6 @@
1042 1042  [[image:image-20220607171554-8.png]]
1043 1043  
1044 1044  
1045 -
1046 1046  (((
1047 1047  (% style="color:#037691" %)**Downlink Command: 0x01**
1048 1048  )))
... ... @@ -1196,7 +1196,7 @@
1196 1196  )))
1197 1197  
1198 1198  (((
1199 -The discharge curve is not linear so cant simply use percentage to show the battery level. Below is the battery performance.
1190 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1200 1200  )))
1201 1201  
1202 1202  [[image:1654593587246-335.png]]
... ... @@ -1250,13 +1250,13 @@
1250 1250  The battery related documents as below:
1251 1251  
1252 1252  * (((
1253 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1244 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
1254 1254  )))
1255 1255  * (((
1256 1256  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1257 1257  )))
1258 1258  * (((
1259 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1250 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
1260 1260  )))
1261 1261  
1262 1262  [[image:image-20220607172042-11.png]]
... ... @@ -1320,9 +1320,9 @@
1320 1320  
1321 1321  = 7. Trouble Shooting =
1322 1322  
1323 -== 7.1 AT Commands input doesnt work ==
1314 +== 7.1 AT Commands input doesn't work ==
1324 1324  
1325 -In the case if user can see the console output but cant type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1316 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1326 1326  
1327 1327  
1328 1328  
... ... @@ -1342,6 +1342,10 @@
1342 1342  * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1343 1343  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1344 1344  
1336 +
1337 +
1338 +
1339 +
1345 1345  = 9. ​Packing Info =
1346 1346  
1347 1347  
... ... @@ -1356,6 +1356,10 @@
1356 1356  * Package Size / pcs : cm
1357 1357  * Weight / pcs : g
1358 1358  
1354 +
1355 +
1356 +
1357 +
1359 1359  = 10. ​Support =
1360 1360  
1361 1361  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0