Last modified by Xiaoling on 2025/04/25 14:08

From version 86.5
edited by Xiaoling
on 2022/06/14 14:31
Change comment: There is no comment for this version
To version 98.9
edited by Xiaoling
on 2022/08/18 16:33
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,68 +4,31 @@
4 4  
5 5  
6 6  
7 +
8 +
9 +
10 +
11 +
12 +
13 +
14 +
15 +
7 7  **Table of Contents:**
8 8  
9 -* [[1. Introduction>>path:#H1.Introduction]]
10 -** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 -** [[​1.2 Features>>path:#H200B1.2Features]]
12 -** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 -** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 -** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 -* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 -** [[2.1 How it works>>path:#H2.1Howitworks]]
17 -** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 -** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 -*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 -*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 -*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 -*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 -*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 -*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 -*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 -** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 -** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 -** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 -*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 -*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 -*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 -** [[2.7 Calibration>>path:#H2.7Calibration]]
33 -** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 -*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 -*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 -*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 -*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 -*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 -*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 -*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 -** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 -** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 -* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 -** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 -** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 -** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 -** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 -* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 -** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 -** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 -** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 -*** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 -*** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 -* [[5. Use AT Command>>path:#H5.UseATCommand]]
55 -** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 -* [[6. FAQ>>path:#H6.FAQ]]
57 -** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 -* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 -** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 -* [[8. Order Info>>path:#H8.OrderInfo]]
61 -* [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 -* [[10. ​Support>>path:#H10.A0200BSupport]]
18 +{{toc/}}
63 63  
64 64  
65 65  
66 66  
23 +
24 +
25 +
26 +
27 +
28 +
67 67  = 1. Introduction =
68 68  
31 +
69 69  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
70 70  
71 71  (((
... ... @@ -98,6 +98,7 @@
98 98  
99 99  == ​1.2 Features ==
100 100  
64 +
101 101  * LoRaWAN 1.0.3 Class A
102 102  * Ultra-low power consumption
103 103  * Monitor soil pH with temperature compensation.
... ... @@ -115,6 +115,7 @@
115 115  
116 116  
117 117  
82 +
118 118  == 1.3 Probe Specification ==
119 119  
120 120  
... ... @@ -127,7 +127,6 @@
127 127  * IP68 Protection
128 128  * Length: 3.5 meters
129 129  
130 -
131 131  (% style="color:#4f81bd" %)**Soil Temperature:**
132 132  
133 133  * Range -40℃~85℃
... ... @@ -139,12 +139,18 @@
139 139  
140 140  
141 141  
106 +
142 142  == 1.4 ​Applications ==
143 143  
109 +
144 144  * Smart Agriculture
145 145  
112 +
113 +
114 +
146 146  == 1.5 Pin mapping and power on ==
147 147  
117 +
148 148  [[image:1654592472094-134.png]]
149 149  
150 150  
... ... @@ -151,19 +151,23 @@
151 151  
152 152  = 2. Configure LSPH01 to connect to LoRaWAN network =
153 153  
124 +
154 154  == 2.1 How it works ==
155 155  
127 +
156 156  (((
157 157  The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
158 158  )))
159 159  
160 160  (((
161 -In case you cant set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
133 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
162 162  )))
163 163  
164 164  
137 +
165 165  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
166 166  
140 +
167 167  (((
168 168  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
169 169  )))
... ... @@ -170,10 +170,14 @@
170 170  
171 171  (((
172 172  [[image:1654592492399-921.png]]
147 +
148 +
173 173  )))
174 174  
175 175  (((
176 176  The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
153 +
154 +
177 177  )))
178 178  
179 179  (((
... ... @@ -197,11 +197,13 @@
197 197  [[image:1654592600093-601.png]]
198 198  
199 199  
178 +
200 200  **Add APP EUI and DEV EUI**
201 201  
202 202  [[image:1654592619856-881.png]]
203 203  
204 204  
184 +
205 205  **Add APP EUI in the application**
206 206  
207 207  [[image:1654592632656-512.png]]
... ... @@ -223,6 +223,8 @@
223 223  
224 224  (((
225 225  (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
206 +
207 +
226 226  )))
227 227  
228 228  [[image:1654592697690-910.png]]
... ... @@ -231,6 +231,7 @@
231 231  
232 232  == 2.3 ​Uplink Payload ==
233 233  
216 +
234 234  (((
235 235  LSPH01 will uplink payload via LoRaWAN with below payload format: 
236 236  )))
... ... @@ -274,6 +274,7 @@
274 274  
275 275  === 2.3.2 DS18B20 Temperature sensor ===
276 276  
260 +
277 277  This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
278 278  
279 279  
... ... @@ -287,6 +287,7 @@
287 287  
288 288  === 2.3.3 Soil pH ===
289 289  
274 +
290 290  Range: 0 ~~ 14 pH
291 291  
292 292  **Example:**
... ... @@ -297,6 +297,7 @@
297 297  
298 298  === 2.3.4 Soil Temperature ===
299 299  
285 +
300 300  Get Soil Temperature 
301 301  
302 302  
... ... @@ -310,6 +310,7 @@
310 310  
311 311  === 2.3.5 Interrupt Pin ===
312 312  
299 +
313 313  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
314 314  
315 315  
... ... @@ -323,6 +323,7 @@
323 323  
324 324  === 2.3.6 Message Type ===
325 325  
313 +
326 326  (((
327 327  For a normal uplink payload, the message type is always 0x01.
328 328  )))
... ... @@ -338,6 +338,10 @@
338 338  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
339 339  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
340 340  
329 +
330 +
331 +
332 +
341 341  === 2.3.7 Decode payload in The Things Network ===
342 342  
343 343  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -350,7 +350,7 @@
350 350  )))
351 351  
352 352  (((
353 -LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
345 +LSPH01 TTN Payload Decoder:  [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
354 354  )))
355 355  
356 356  
... ... @@ -357,6 +357,7 @@
357 357  
358 358  == 2.4 Uplink Interval ==
359 359  
352 +
360 360  The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
361 361  
362 362  
... ... @@ -363,6 +363,7 @@
363 363  
364 364  == 2.5 ​Show Data in DataCake IoT Server ==
365 365  
359 +
366 366  (((
367 367  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
368 368  )))
... ... @@ -405,7 +405,7 @@
405 405  )))
406 406  
407 407  (((
408 -Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
402 +Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
409 409  )))
410 410  
411 411  
... ... @@ -426,8 +426,10 @@
426 426  
427 427  == 2.6 Installation and Maintain ==
428 428  
423 +
429 429  === 2.6.1 Before measurement ===
430 430  
426 +
431 431  (((
432 432  (((
433 433  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
... ... @@ -445,6 +445,8 @@
445 445  
446 446  (((
447 447  [[image:1654592946732-634.png]]
444 +
445 +
448 448  )))
449 449  
450 450  (((
... ... @@ -456,7 +456,7 @@
456 456  )))
457 457  
458 458  (((
459 -Slowly insert the probe to the measure point. Dont use large force which will break the probe. Make sure not shake when inserting.
457 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting.
460 460  )))
461 461  
462 462  (((
... ... @@ -483,6 +483,7 @@
483 483  
484 484  === 2.6.3 Maintain Probe ===
485 485  
484 +
486 486  1. (((
487 487  pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
488 488  )))
... ... @@ -507,6 +507,7 @@
507 507  
508 508  == 2.7 Calibration ==
509 509  
509 +
510 510  (((
511 511  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
512 512  )))
... ... @@ -538,6 +538,7 @@
538 538  Always 0x03
539 539  )))
540 540  
541 +
541 541  User can also send 0x14 downlink command to poll the current calibration payload.
542 542  
543 543  [[image:image-20220607171416-7.jpeg]]
... ... @@ -547,15 +547,20 @@
547 547  * Reply to non-confirmed packet: 14 00
548 548  
549 549  
551 +
552 +
550 550  == 2.8 Frequency Plans ==
551 551  
555 +
552 552  (((
553 553  The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
554 554  )))
555 555  
556 556  
561 +
557 557  === 2.8.1 EU863-870 (EU868) ===
558 558  
564 +
559 559  (((
560 560  (% style="color:blue" %)**Uplink:**
561 561  )))
... ... @@ -616,6 +616,7 @@
616 616  
617 617  === 2.8.2 US902-928(US915) ===
618 618  
625 +
619 619  (((
620 620  Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
621 621  )))
... ... @@ -629,11 +629,15 @@
629 629  )))
630 630  
631 631  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
632 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
639 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
633 633  
634 634  
642 +
643 +
644 +
635 635  === 2.8.3 CN470-510 (CN470) ===
636 636  
647 +
637 637  (((
638 638  Used in China, Default use CHE=1
639 639  )))
... ... @@ -722,6 +722,7 @@
722 722  
723 723  === 2.8.4 AU915-928(AU915) ===
724 724  
736 +
725 725  (((
726 726  Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
727 727  )))
... ... @@ -739,10 +739,15 @@
739 739  )))
740 740  
741 741  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
742 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
754 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
743 743  
756 +
757 +
758 +
759 +
744 744  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
745 745  
762 +
746 746  (((
747 747  (% style="color:blue" %)**Default Uplink channel:**
748 748  )))
... ... @@ -851,6 +851,7 @@
851 851  
852 852  === 2.8.6 KR920-923 (KR920) ===
853 853  
871 +
854 854  (((
855 855  (% style="color:blue" %)**Default channel:**
856 856  )))
... ... @@ -923,6 +923,7 @@
923 923  
924 924  === 2.8.7 IN865-867 (IN865) ===
925 925  
944 +
926 926  (((
927 927  (% style="color:blue" %)**Uplink:**
928 928  )))
... ... @@ -959,19 +959,22 @@
959 959  
960 960  == 2.9 LED Indicator ==
961 961  
981 +
962 962  The LSPH01 has an internal LED which is to show the status of different state.
963 963  
964 964  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
965 965  * Blink once when device transmit a packet.
966 966  
967 -== 2.10 ​Firmware Change Log ==
968 968  
969 969  
970 -**Firmware download link:**
971 971  
972 -[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
973 973  
991 +== 2.10 ​Firmware Change Log ==
974 974  
993 +
994 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]]
995 +
996 +
975 975  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
976 976  
977 977  
... ... @@ -1009,7 +1009,7 @@
1009 1009  )))
1010 1010  
1011 1011  (((
1012 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1034 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1013 1013  )))
1014 1014  
1015 1015  (((
... ... @@ -1035,7 +1035,6 @@
1035 1035  [[image:image-20220607171554-8.png]]
1036 1036  
1037 1037  
1038 -
1039 1039  (((
1040 1040  (% style="color:#037691" %)**Downlink Command: 0x01**
1041 1041  )))
... ... @@ -1091,7 +1091,6 @@
1091 1091  )))
1092 1092  
1093 1093  
1094 -
1095 1095  == 3.3 Calibrate Sensor ==
1096 1096  
1097 1097  Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
... ... @@ -1130,10 +1130,10 @@
1130 1130  Always 0x02
1131 1131  )))
1132 1132  
1133 -**Software Type**: Always 0x03 for LSPH01
1153 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01
1134 1134  
1135 1135  
1136 -**Frequency Band**:
1156 +(% style="color:#037691" %)**Frequency Band**:
1137 1137  
1138 1138  *0x01: EU868
1139 1139  
... ... @@ -1156,13 +1156,13 @@
1156 1156  *0xa0: AS923-3
1157 1157  
1158 1158  
1159 -**Sub-Band**: value 0x00 ~~ 0x08
1179 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08
1160 1160  
1161 1161  
1162 -**Firmware Version**: 0x0100, Means: v1.0.0 version
1182 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
1163 1163  
1164 1164  
1165 -**Sensor Type**:
1185 +(% style="color:#037691" %)**Sensor Type**:
1166 1166  
1167 1167  0x01: LSE01
1168 1168  
... ... @@ -1189,7 +1189,7 @@
1189 1189  )))
1190 1190  
1191 1191  (((
1192 -The discharge curve is not linear so cant simply use percentage to show the battery level. Below is the battery performance.
1212 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1193 1193  )))
1194 1194  
1195 1195  [[image:1654593587246-335.png]]
... ... @@ -1224,12 +1224,12 @@
1224 1224  )))
1225 1225  
1226 1226  
1227 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1247 +(% style="color:#037691" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1228 1228  
1229 1229  [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1230 1230  
1231 1231  
1232 -**Step 2**: Open it and choose
1252 +(% style="color:#037691" %)**Step 2**(%%): Open it and choose
1233 1233  
1234 1234  * Product Model
1235 1235  * Uplink Interval
... ... @@ -1243,13 +1243,13 @@
1243 1243  The battery related documents as below:
1244 1244  
1245 1245  * (((
1246 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1266 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
1247 1247  )))
1248 1248  * (((
1249 1249  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1250 1250  )))
1251 1251  * (((
1252 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1272 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
1253 1253  )))
1254 1254  
1255 1255  [[image:image-20220607172042-11.png]]
... ... @@ -1267,11 +1267,11 @@
1267 1267  === ​4.3.2 Replace the battery ===
1268 1268  
1269 1269  (((
1270 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there wont be voltage drop between battery and main board.
1290 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
1271 1271  )))
1272 1272  
1273 1273  (((
1274 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user cant find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1294 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1275 1275  )))
1276 1276  
1277 1277  
... ... @@ -1313,9 +1313,9 @@
1313 1313  
1314 1314  = 7. Trouble Shooting =
1315 1315  
1316 -== 7.1 AT Commands input doesnt work ==
1336 +== 7.1 AT Commands input doesn't work ==
1317 1317  
1318 -In the case if user can see the console output but cant type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1338 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1319 1319  
1320 1320  
1321 1321  
... ... @@ -1335,6 +1335,7 @@
1335 1335  * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1336 1336  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1337 1337  
1358 +
1338 1338  = 9. ​Packing Info =
1339 1339  
1340 1340  
... ... @@ -1349,6 +1349,7 @@
1349 1349  * Package Size / pcs : cm
1350 1350  * Weight / pcs : g
1351 1351  
1373 +
1352 1352  = 10. ​Support =
1353 1353  
1354 1354  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.