Changes for page LSPH01 -- LoRaWAN Soil pH Sensor User Manual
Last modified by Xiaoling on 2025/04/25 14:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,68 +4,31 @@ 4 4 5 5 6 6 7 + 8 + 9 + 10 + 11 + 12 + 13 + 14 + 15 + 7 7 **Table of Contents:** 8 8 9 -* [[1. Introduction>>path:#H1.Introduction]] 10 -** [[1.1 What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]] 11 -** [[1.2 Features>>path:#H200B1.2Features]] 12 -** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]] 13 -** [[1.4 Applications>>path:#H1.4200BApplications]] 14 -** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]] 15 -* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]] 16 -** [[2.1 How it works>>path:#H2.1Howitworks]] 17 -** [[2.2 Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]] 18 -** [[2.3 Uplink Payload>>path:#H2.3200BUplinkPayload]] 19 -*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]] 20 -*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]] 21 -*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]] 22 -*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]] 23 -*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]] 24 -*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]] 25 -*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]] 26 -** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]] 27 -** [[2.5 Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]] 28 -** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]] 29 -*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]] 30 -*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]] 31 -*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]] 32 -** [[2.7 Calibration>>path:#H2.7Calibration]] 33 -** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]] 34 -*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]] 35 -*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]] 36 -*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]] 37 -*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]] 38 -*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]] 39 -*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]] 40 -*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]] 41 -** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]] 42 -** [[2.10 Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]] 43 -* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]] 44 -** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]] 45 -** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]] 46 -** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]] 47 -** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]] 48 -* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]] 49 -** [[4.1 Battery Type>>path:#H4.1BatteryType]] 50 -** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]] 51 -** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]] 52 -*** [[4.3.1 Battery Note>>path:#H4.3.1200BBatteryNote]] 53 -*** [[4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]] 54 -* [[5. Use AT Command>>path:#H5.UseATCommand]] 55 -** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]] 56 -* [[6. FAQ>>path:#H6.FAQ]] 57 -** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]] 58 -* [[7. Trouble Shooting>>path:#H7.TroubleShooting]] 59 -** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]] 60 -* [[8. Order Info>>path:#H8.OrderInfo]] 61 -* [[9. Packing Info>>path:#H9.200BPackingInfo]] 62 -* [[10. Support>>path:#H10.A0200BSupport]] 18 +{{toc/}} 63 63 64 64 65 65 66 66 23 + 24 + 25 + 26 + 27 + 28 + 67 67 = 1. Introduction = 68 68 31 + 69 69 == 1.1 What is LoRaWAN Soil pH Sensor == 70 70 71 71 ((( ... ... @@ -98,6 +98,7 @@ 98 98 99 99 == 1.2 Features == 100 100 64 + 101 101 * LoRaWAN 1.0.3 Class A 102 102 * Ultra-low power consumption 103 103 * Monitor soil pH with temperature compensation. ... ... @@ -115,6 +115,7 @@ 115 115 116 116 117 117 82 + 118 118 == 1.3 Probe Specification == 119 119 120 120 ... ... @@ -135,12 +135,21 @@ 135 135 * IP68 Protection 136 136 * Length: 3.5 meters 137 137 103 + 104 + 105 + 106 + 138 138 == 1.4 Applications == 139 139 109 + 140 140 * Smart Agriculture 141 141 112 + 113 + 114 + 142 142 == 1.5 Pin mapping and power on == 143 143 117 + 144 144 [[image:1654592472094-134.png]] 145 145 146 146 ... ... @@ -147,19 +147,23 @@ 147 147 148 148 = 2. Configure LSPH01 to connect to LoRaWAN network = 149 149 124 + 150 150 == 2.1 How it works == 151 151 127 + 152 152 ((( 153 153 The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 154 154 ))) 155 155 156 156 ((( 157 -In case you can ’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.133 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01. 158 158 ))) 159 159 160 160 137 + 161 161 == 2.2 Quick guide to connect to LoRaWAN server (OTAA) == 162 162 140 + 163 163 ((( 164 164 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example. 165 165 ))) ... ... @@ -166,10 +166,14 @@ 166 166 167 167 ((( 168 168 [[image:1654592492399-921.png]] 147 + 148 + 169 169 ))) 170 170 171 171 ((( 172 172 The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 153 + 154 + 173 173 ))) 174 174 175 175 ((( ... ... @@ -193,11 +193,13 @@ 193 193 [[image:1654592600093-601.png]] 194 194 195 195 178 + 196 196 **Add APP EUI and DEV EUI** 197 197 198 198 [[image:1654592619856-881.png]] 199 199 200 200 184 + 201 201 **Add APP EUI in the application** 202 202 203 203 [[image:1654592632656-512.png]] ... ... @@ -219,6 +219,8 @@ 219 219 220 220 ((( 221 221 (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel. 206 + 207 + 222 222 ))) 223 223 224 224 [[image:1654592697690-910.png]] ... ... @@ -227,6 +227,7 @@ 227 227 228 228 == 2.3 Uplink Payload == 229 229 216 + 230 230 ((( 231 231 LSPH01 will uplink payload via LoRaWAN with below payload format: 232 232 ))) ... ... @@ -270,6 +270,7 @@ 270 270 271 271 === 2.3.2 DS18B20 Temperature sensor === 272 272 260 + 273 273 This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature. 274 274 275 275 ... ... @@ -283,6 +283,7 @@ 283 283 284 284 === 2.3.3 Soil pH === 285 285 274 + 286 286 Range: 0 ~~ 14 pH 287 287 288 288 **Example:** ... ... @@ -293,6 +293,7 @@ 293 293 294 294 === 2.3.4 Soil Temperature === 295 295 285 + 296 296 Get Soil Temperature 297 297 298 298 ... ... @@ -306,6 +306,7 @@ 306 306 307 307 === 2.3.5 Interrupt Pin === 308 308 299 + 309 309 This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up. 310 310 311 311 ... ... @@ -319,6 +319,7 @@ 319 319 320 320 === 2.3.6 Message Type === 321 321 313 + 322 322 ((( 323 323 For a normal uplink payload, the message type is always 0x01. 324 324 ))) ... ... @@ -334,6 +334,10 @@ 334 334 |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]] 335 335 |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]] 336 336 329 + 330 + 331 + 332 + 337 337 === 2.3.7 Decode payload in The Things Network === 338 338 339 339 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -346,7 +346,7 @@ 346 346 ))) 347 347 348 348 ((( 349 -LSPH01 TTN Payload Decoder: agino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]345 +LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]] 350 350 ))) 351 351 352 352 ... ... @@ -353,6 +353,7 @@ 353 353 354 354 == 2.4 Uplink Interval == 355 355 352 + 356 356 The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] 357 357 358 358 ... ... @@ -359,6 +359,7 @@ 359 359 360 360 == 2.5 Show Data in DataCake IoT Server == 361 361 359 + 362 362 ((( 363 363 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 364 364 ))) ... ... @@ -401,7 +401,7 @@ 401 401 ))) 402 402 403 403 ((( 404 -Download Datacake decoder from: [[https:~~/~~/www.dr agino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]402 +Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]] 405 405 ))) 406 406 407 407 ... ... @@ -422,8 +422,10 @@ 422 422 423 423 == 2.6 Installation and Maintain == 424 424 423 + 425 425 === 2.6.1 Before measurement === 426 426 426 + 427 427 ((( 428 428 ((( 429 429 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. ... ... @@ -441,6 +441,8 @@ 441 441 442 442 ((( 443 443 [[image:1654592946732-634.png]] 444 + 445 + 444 444 ))) 445 445 446 446 ((( ... ... @@ -452,7 +452,7 @@ 452 452 ))) 453 453 454 454 ((( 455 -Slowly insert the probe to the measure point. Don ’t use large force which will break the probe. Make sure not shake when inserting.457 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting. 456 456 ))) 457 457 458 458 ((( ... ... @@ -479,6 +479,7 @@ 479 479 480 480 === 2.6.3 Maintain Probe === 481 481 484 + 482 482 1. ((( 483 483 pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 484 484 ))) ... ... @@ -503,6 +503,7 @@ 503 503 504 504 == 2.7 Calibration == 505 505 509 + 506 506 ((( 507 507 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 508 508 ))) ... ... @@ -534,6 +534,7 @@ 534 534 Always 0x03 535 535 ))) 536 536 541 + 537 537 User can also send 0x14 downlink command to poll the current calibration payload. 538 538 539 539 [[image:image-20220607171416-7.jpeg]] ... ... @@ -543,15 +543,20 @@ 543 543 * Reply to non-confirmed packet: 14 00 544 544 545 545 551 + 552 + 546 546 == 2.8 Frequency Plans == 547 547 555 + 548 548 ((( 549 549 The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 550 550 ))) 551 551 552 552 561 + 553 553 === 2.8.1 EU863-870 (EU868) === 554 554 564 + 555 555 ((( 556 556 (% style="color:blue" %)**Uplink:** 557 557 ))) ... ... @@ -612,6 +612,7 @@ 612 612 613 613 === 2.8.2 US902-928(US915) === 614 614 625 + 615 615 ((( 616 616 Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document. 617 617 ))) ... ... @@ -625,11 +625,15 @@ 625 625 ))) 626 626 627 627 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 628 -* Use the Join successful sub-band if the server doesn ’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)639 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 629 629 630 630 642 + 643 + 644 + 631 631 === 2.8.3 CN470-510 (CN470) === 632 632 647 + 633 633 ((( 634 634 Used in China, Default use CHE=1 635 635 ))) ... ... @@ -718,6 +718,7 @@ 718 718 719 719 === 2.8.4 AU915-928(AU915) === 720 720 736 + 721 721 ((( 722 722 Frequency band as per definition in LoRaWAN 1.0.3 Regional document. 723 723 ))) ... ... @@ -735,10 +735,15 @@ 735 735 ))) 736 736 737 737 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 738 -* Use the Join successful sub-band if the server doesn ’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)754 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 739 739 756 + 757 + 758 + 759 + 740 740 === 2.8.5 AS920-923 & AS923-925 (AS923) === 741 741 762 + 742 742 ((( 743 743 (% style="color:blue" %)**Default Uplink channel:** 744 744 ))) ... ... @@ -847,6 +847,7 @@ 847 847 848 848 === 2.8.6 KR920-923 (KR920) === 849 849 871 + 850 850 ((( 851 851 (% style="color:blue" %)**Default channel:** 852 852 ))) ... ... @@ -919,6 +919,7 @@ 919 919 920 920 === 2.8.7 IN865-867 (IN865) === 921 921 944 + 922 922 ((( 923 923 (% style="color:blue" %)**Uplink:** 924 924 ))) ... ... @@ -955,19 +955,22 @@ 955 955 956 956 == 2.9 LED Indicator == 957 957 981 + 958 958 The LSPH01 has an internal LED which is to show the status of different state. 959 959 960 960 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. 961 961 * Blink once when device transmit a packet. 962 962 963 -== 2.10 Firmware Change Log == 964 964 965 965 966 -**Firmware download link:** 967 967 968 -[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]] 969 969 991 +== 2.10 Firmware Change Log == 970 970 993 + 994 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]] 995 + 996 + 971 971 **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]] 972 972 973 973 ... ... @@ -1005,7 +1005,7 @@ 1005 1005 ))) 1006 1006 1007 1007 ((( 1008 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1034 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1009 1009 ))) 1010 1010 1011 1011 ((( ... ... @@ -1031,7 +1031,6 @@ 1031 1031 [[image:image-20220607171554-8.png]] 1032 1032 1033 1033 1034 - 1035 1035 ((( 1036 1036 (% style="color:#037691" %)**Downlink Command: 0x01** 1037 1037 ))) ... ... @@ -1087,7 +1087,6 @@ 1087 1087 ))) 1088 1088 1089 1089 1090 - 1091 1091 == 3.3 Calibrate Sensor == 1092 1092 1093 1093 Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands ... ... @@ -1126,10 +1126,10 @@ 1126 1126 Always 0x02 1127 1127 ))) 1128 1128 1129 -**Software Type**: Always 0x03 for LSPH01 1153 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01 1130 1130 1131 1131 1132 -**Frequency Band**: 1156 +(% style="color:#037691" %)**Frequency Band**: 1133 1133 1134 1134 *0x01: EU868 1135 1135 ... ... @@ -1152,13 +1152,13 @@ 1152 1152 *0xa0: AS923-3 1153 1153 1154 1154 1155 -**Sub-Band**: value 0x00 ~~ 0x08 1179 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08 1156 1156 1157 1157 1158 -**Firmware Version**: 0x0100, Means: v1.0.0 version 1182 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 1159 1159 1160 1160 1161 -**Sensor Type**: 1185 +(% style="color:#037691" %)**Sensor Type**: 1162 1162 1163 1163 0x01: LSE01 1164 1164 ... ... @@ -1185,7 +1185,7 @@ 1185 1185 ))) 1186 1186 1187 1187 ((( 1188 -The discharge curve is not linear so can ’t simply use percentage to show the battery level. Below is the battery performance.1212 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 1189 1189 ))) 1190 1190 1191 1191 [[image:1654593587246-335.png]] ... ... @@ -1220,12 +1220,12 @@ 1220 1220 ))) 1221 1221 1222 1222 1223 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 1247 +(% style="color:#037691" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 1224 1224 1225 1225 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 1226 1226 1227 1227 1228 -**Step 2**: Open it and choose 1252 +(% style="color:#037691" %)**Step 2**(%%): Open it and choose 1229 1229 1230 1230 * Product Model 1231 1231 * Uplink Interval ... ... @@ -1239,13 +1239,13 @@ 1239 1239 The battery related documents as below: 1240 1240 1241 1241 * ((( 1242 -[[Battery Dimension>> url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],1266 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], 1243 1243 ))) 1244 1244 * ((( 1245 1245 [[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 1246 1246 ))) 1247 1247 * ((( 1248 -[[Lithium-ion Battery-Capacitor datasheet>> url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]1272 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]] 1249 1249 ))) 1250 1250 1251 1251 [[image:image-20220607172042-11.png]] ... ... @@ -1263,11 +1263,11 @@ 1263 1263 === 4.3.2 Replace the battery === 1264 1264 1265 1265 ((( 1266 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won ’t be voltage drop between battery and main board.1290 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 1267 1267 ))) 1268 1268 1269 1269 ((( 1270 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can ’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)1294 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 1271 1271 ))) 1272 1272 1273 1273 ... ... @@ -1309,9 +1309,9 @@ 1309 1309 1310 1310 = 7. Trouble Shooting = 1311 1311 1312 -== 7.1 AT Commands input doesn ’t work ==1336 +== 7.1 AT Commands input doesn't work == 1313 1313 1314 -In the case if user can see the console output but can ’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.1338 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1315 1315 1316 1316 1317 1317 ... ... @@ -1331,6 +1331,7 @@ 1331 1331 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1332 1332 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1333 1333 1358 + 1334 1334 = 9. Packing Info = 1335 1335 1336 1336 ... ... @@ -1345,6 +1345,7 @@ 1345 1345 * Package Size / pcs : cm 1346 1346 * Weight / pcs : g 1347 1347 1373 + 1348 1348 = 10. Support = 1349 1349 1350 1350 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.