Last modified by Xiaoling on 2025/04/25 14:08

From version 86.3
edited by Xiaoling
on 2022/06/10 10:59
Change comment: There is no comment for this version
To version 98.9
edited by Xiaoling
on 2022/08/18 16:33
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,72 +4,36 @@
4 4  
5 5  
6 6  
7 -**Contents:**
8 8  
9 -* [[1. Introduction>>path:#H1.Introduction]]
10 -** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 -** [[​1.2 Features>>path:#H200B1.2Features]]
12 -** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 -** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 -** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 -* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 -** [[2.1 How it works>>path:#H2.1Howitworks]]
17 -** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 -** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 -*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 -*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 -*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 -*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 -*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 -*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 -*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 -** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 -** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 -** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 -*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 -*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 -*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 -** [[2.7 Calibration>>path:#H2.7Calibration]]
33 -** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 -*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 -*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 -*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 -*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 -*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 -*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 -*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 -** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 -** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 -* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 -** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 -** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 -** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 -** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 -* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 -** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 -** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 -** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 -*** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 -*** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 -* [[5. Use AT Command>>path:#H5.UseATCommand]]
55 -** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 -* [[6. FAQ>>path:#H6.FAQ]]
57 -** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 -* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 -** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 -* [[8. Order Info>>path:#H8.OrderInfo]]
61 -* [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 -* [[10. ​Support>>path:#H10.A0200BSupport]]
63 63  
64 64  
65 65  
66 66  
67 67  
13 +
14 +
15 +
16 +**Table of Contents:**
17 +
18 +{{toc/}}
19 +
20 +
21 +
22 +
23 +
24 +
25 +
26 +
27 +
28 +
68 68  = 1. Introduction =
69 69  
31 +
70 70  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
71 71  
72 72  (((
35 +
36 +
73 73  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
74 74  )))
75 75  
... ... @@ -97,6 +97,7 @@
97 97  
98 98  == ​1.2 Features ==
99 99  
64 +
100 100  * LoRaWAN 1.0.3 Class A
101 101  * Ultra-low power consumption
102 102  * Monitor soil pH with temperature compensation.
... ... @@ -112,6 +112,9 @@
112 112  * 8500mAh Battery for long term use
113 113  
114 114  
80 +
81 +
82 +
115 115  == 1.3 Probe Specification ==
116 116  
117 117  
... ... @@ -133,13 +133,20 @@
133 133  * Length: 3.5 meters
134 134  
135 135  
104 +
105 +
106 +
136 136  == 1.4 ​Applications ==
137 137  
109 +
138 138  * Smart Agriculture
139 139  
140 140  
113 +
114 +
141 141  == 1.5 Pin mapping and power on ==
142 142  
117 +
143 143  [[image:1654592472094-134.png]]
144 144  
145 145  
... ... @@ -146,19 +146,23 @@
146 146  
147 147  = 2. Configure LSPH01 to connect to LoRaWAN network =
148 148  
124 +
149 149  == 2.1 How it works ==
150 150  
127 +
151 151  (((
152 152  The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
153 153  )))
154 154  
155 155  (((
156 -In case you cant set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
133 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
157 157  )))
158 158  
159 159  
137 +
160 160  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
161 161  
140 +
162 162  (((
163 163  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
164 164  )))
... ... @@ -165,10 +165,14 @@
165 165  
166 166  (((
167 167  [[image:1654592492399-921.png]]
147 +
148 +
168 168  )))
169 169  
170 170  (((
171 171  The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
153 +
154 +
172 172  )))
173 173  
174 174  (((
... ... @@ -192,11 +192,13 @@
192 192  [[image:1654592600093-601.png]]
193 193  
194 194  
178 +
195 195  **Add APP EUI and DEV EUI**
196 196  
197 197  [[image:1654592619856-881.png]]
198 198  
199 199  
184 +
200 200  **Add APP EUI in the application**
201 201  
202 202  [[image:1654592632656-512.png]]
... ... @@ -218,6 +218,8 @@
218 218  
219 219  (((
220 220  (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
206 +
207 +
221 221  )))
222 222  
223 223  [[image:1654592697690-910.png]]
... ... @@ -226,6 +226,7 @@
226 226  
227 227  == 2.3 ​Uplink Payload ==
228 228  
216 +
229 229  (((
230 230  LSPH01 will uplink payload via LoRaWAN with below payload format: 
231 231  )))
... ... @@ -269,6 +269,7 @@
269 269  
270 270  === 2.3.2 DS18B20 Temperature sensor ===
271 271  
260 +
272 272  This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
273 273  
274 274  
... ... @@ -282,6 +282,7 @@
282 282  
283 283  === 2.3.3 Soil pH ===
284 284  
274 +
285 285  Range: 0 ~~ 14 pH
286 286  
287 287  **Example:**
... ... @@ -292,6 +292,7 @@
292 292  
293 293  === 2.3.4 Soil Temperature ===
294 294  
285 +
295 295  Get Soil Temperature 
296 296  
297 297  
... ... @@ -305,6 +305,7 @@
305 305  
306 306  === 2.3.5 Interrupt Pin ===
307 307  
299 +
308 308  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
309 309  
310 310  
... ... @@ -318,6 +318,7 @@
318 318  
319 319  === 2.3.6 Message Type ===
320 320  
313 +
321 321  (((
322 322  For a normal uplink payload, the message type is always 0x01.
323 323  )))
... ... @@ -334,6 +334,9 @@
334 334  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
335 335  
336 336  
330 +
331 +
332 +
337 337  === 2.3.7 Decode payload in The Things Network ===
338 338  
339 339  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -346,7 +346,7 @@
346 346  )))
347 347  
348 348  (((
349 -LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
345 +LSPH01 TTN Payload Decoder:  [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
350 350  )))
351 351  
352 352  
... ... @@ -353,6 +353,7 @@
353 353  
354 354  == 2.4 Uplink Interval ==
355 355  
352 +
356 356  The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
357 357  
358 358  
... ... @@ -359,6 +359,7 @@
359 359  
360 360  == 2.5 ​Show Data in DataCake IoT Server ==
361 361  
359 +
362 362  (((
363 363  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
364 364  )))
... ... @@ -401,7 +401,7 @@
401 401  )))
402 402  
403 403  (((
404 -Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
402 +Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
405 405  )))
406 406  
407 407  
... ... @@ -422,8 +422,10 @@
422 422  
423 423  == 2.6 Installation and Maintain ==
424 424  
423 +
425 425  === 2.6.1 Before measurement ===
426 426  
426 +
427 427  (((
428 428  (((
429 429  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
... ... @@ -441,6 +441,8 @@
441 441  
442 442  (((
443 443  [[image:1654592946732-634.png]]
444 +
445 +
444 444  )))
445 445  
446 446  (((
... ... @@ -452,7 +452,7 @@
452 452  )))
453 453  
454 454  (((
455 -Slowly insert the probe to the measure point. Dont use large force which will break the probe. Make sure not shake when inserting.
457 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting.
456 456  )))
457 457  
458 458  (((
... ... @@ -479,6 +479,7 @@
479 479  
480 480  === 2.6.3 Maintain Probe ===
481 481  
484 +
482 482  1. (((
483 483  pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
484 484  )))
... ... @@ -503,6 +503,7 @@
503 503  
504 504  == 2.7 Calibration ==
505 505  
509 +
506 506  (((
507 507  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
508 508  )))
... ... @@ -534,6 +534,7 @@
534 534  Always 0x03
535 535  )))
536 536  
541 +
537 537  User can also send 0x14 downlink command to poll the current calibration payload.
538 538  
539 539  [[image:image-20220607171416-7.jpeg]]
... ... @@ -544,15 +544,19 @@
544 544  
545 545  
546 546  
552 +
547 547  == 2.8 Frequency Plans ==
548 548  
555 +
549 549  (((
550 550  The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
551 551  )))
552 552  
553 553  
561 +
554 554  === 2.8.1 EU863-870 (EU868) ===
555 555  
564 +
556 556  (((
557 557  (% style="color:blue" %)**Uplink:**
558 558  )))
... ... @@ -613,6 +613,7 @@
613 613  
614 614  === 2.8.2 US902-928(US915) ===
615 615  
625 +
616 616  (((
617 617  Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
618 618  )))
... ... @@ -626,12 +626,15 @@
626 626  )))
627 627  
628 628  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
629 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
639 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
630 630  
631 631  
632 632  
643 +
644 +
633 633  === 2.8.3 CN470-510 (CN470) ===
634 634  
647 +
635 635  (((
636 636  Used in China, Default use CHE=1
637 637  )))
... ... @@ -720,6 +720,7 @@
720 720  
721 721  === 2.8.4 AU915-928(AU915) ===
722 722  
736 +
723 723  (((
724 724  Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
725 725  )))
... ... @@ -737,11 +737,15 @@
737 737  )))
738 738  
739 739  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
740 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
754 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
741 741  
742 742  
757 +
758 +
759 +
743 743  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
744 744  
762 +
745 745  (((
746 746  (% style="color:blue" %)**Default Uplink channel:**
747 747  )))
... ... @@ -850,6 +850,7 @@
850 850  
851 851  === 2.8.6 KR920-923 (KR920) ===
852 852  
871 +
853 853  (((
854 854  (% style="color:blue" %)**Default channel:**
855 855  )))
... ... @@ -922,6 +922,7 @@
922 922  
923 923  === 2.8.7 IN865-867 (IN865) ===
924 924  
944 +
925 925  (((
926 926  (% style="color:blue" %)**Uplink:**
927 927  )))
... ... @@ -958,6 +958,7 @@
958 958  
959 959  == 2.9 LED Indicator ==
960 960  
981 +
961 961  The LSPH01 has an internal LED which is to show the status of different state.
962 962  
963 963  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
... ... @@ -964,14 +964,15 @@
964 964  * Blink once when device transmit a packet.
965 965  
966 966  
967 -== 2.10 ​Firmware Change Log ==
968 968  
969 969  
970 -**Firmware download link:**
971 971  
972 -[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
991 +== 2.10 ​Firmware Change Log ==
973 973  
974 974  
994 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]]
995 +
996 +
975 975  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
976 976  
977 977  
... ... @@ -1009,7 +1009,7 @@
1009 1009  )))
1010 1010  
1011 1011  (((
1012 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1034 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1013 1013  )))
1014 1014  
1015 1015  (((
... ... @@ -1035,7 +1035,6 @@
1035 1035  [[image:image-20220607171554-8.png]]
1036 1036  
1037 1037  
1038 -
1039 1039  (((
1040 1040  (% style="color:#037691" %)**Downlink Command: 0x01**
1041 1041  )))
... ... @@ -1091,7 +1091,6 @@
1091 1091  )))
1092 1092  
1093 1093  
1094 -
1095 1095  == 3.3 Calibrate Sensor ==
1096 1096  
1097 1097  Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
... ... @@ -1109,7 +1109,6 @@
1109 1109  * Reply to the confirmation package: 26 01
1110 1110  * Reply to non-confirmed packet: 26 00
1111 1111  
1112 -
1113 1113  Device will send an uplink after got this downlink command. With below payload:
1114 1114  
1115 1115  Configures info payload:
... ... @@ -1131,10 +1131,10 @@
1131 1131  Always 0x02
1132 1132  )))
1133 1133  
1134 -**Software Type**: Always 0x03 for LSPH01
1153 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01
1135 1135  
1136 1136  
1137 -**Frequency Band**:
1156 +(% style="color:#037691" %)**Frequency Band**:
1138 1138  
1139 1139  *0x01: EU868
1140 1140  
... ... @@ -1157,13 +1157,13 @@
1157 1157  *0xa0: AS923-3
1158 1158  
1159 1159  
1160 -**Sub-Band**: value 0x00 ~~ 0x08
1179 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08
1161 1161  
1162 1162  
1163 -**Firmware Version**: 0x0100, Means: v1.0.0 version
1182 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
1164 1164  
1165 1165  
1166 -**Sensor Type**:
1185 +(% style="color:#037691" %)**Sensor Type**:
1167 1167  
1168 1168  0x01: LSE01
1169 1169  
... ... @@ -1190,7 +1190,7 @@
1190 1190  )))
1191 1191  
1192 1192  (((
1193 -The discharge curve is not linear so cant simply use percentage to show the battery level. Below is the battery performance.
1212 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1194 1194  )))
1195 1195  
1196 1196  [[image:1654593587246-335.png]]
... ... @@ -1225,12 +1225,12 @@
1225 1225  )))
1226 1226  
1227 1227  
1228 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1247 +(% style="color:#037691" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1229 1229  
1230 1230  [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1231 1231  
1232 1232  
1233 -**Step 2**: Open it and choose
1252 +(% style="color:#037691" %)**Step 2**(%%): Open it and choose
1234 1234  
1235 1235  * Product Model
1236 1236  * Uplink Interval
... ... @@ -1244,13 +1244,13 @@
1244 1244  The battery related documents as below:
1245 1245  
1246 1246  * (((
1247 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1266 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
1248 1248  )))
1249 1249  * (((
1250 1250  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1251 1251  )))
1252 1252  * (((
1253 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1272 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
1254 1254  )))
1255 1255  
1256 1256  [[image:image-20220607172042-11.png]]
... ... @@ -1268,11 +1268,11 @@
1268 1268  === ​4.3.2 Replace the battery ===
1269 1269  
1270 1270  (((
1271 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there wont be voltage drop between battery and main board.
1290 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
1272 1272  )))
1273 1273  
1274 1274  (((
1275 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user cant find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1294 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1276 1276  )))
1277 1277  
1278 1278  
... ... @@ -1314,9 +1314,9 @@
1314 1314  
1315 1315  = 7. Trouble Shooting =
1316 1316  
1317 -== 7.1 AT Commands input doesnt work ==
1336 +== 7.1 AT Commands input doesn't work ==
1318 1318  
1319 -In the case if user can see the console output but cant type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1338 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1320 1320  
1321 1321  
1322 1322  
... ... @@ -1336,6 +1336,7 @@
1336 1336  * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1337 1337  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1338 1338  
1358 +
1339 1339  = 9. ​Packing Info =
1340 1340  
1341 1341  
... ... @@ -1350,6 +1350,7 @@
1350 1350  * Package Size / pcs : cm
1351 1351  * Weight / pcs : g
1352 1352  
1373 +
1353 1353  = 10. ​Support =
1354 1354  
1355 1355  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.