<
From version < 86.10 >
edited by Xiaoling
on 2022/06/14 14:35
To version < 99.6 >
edited by Xiaoling
on 2023/05/23 16:45
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,73 +4,22 @@
4 4  
5 5  
6 6  
7 +
7 7  **Table of Contents:**
8 8  
9 -* [[1. Introduction>>path:#H1.Introduction]]
10 -** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 -** [[​1.2 Features>>path:#H200B1.2Features]]
12 -** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 -** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 -** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 -* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 -** [[2.1 How it works>>path:#H2.1Howitworks]]
17 -** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 -** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 -*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 -*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 -*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 -*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 -*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 -*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 -*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 -** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 -** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 -** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 -*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 -*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 -*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 -** [[2.7 Calibration>>path:#H2.7Calibration]]
33 -** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 -*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 -*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 -*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 -*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 -*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 -*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 -*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 -** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 -** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 -* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 -** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 -** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 -** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 -** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 -* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 -** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 -** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 -** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 -*** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 -*** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 -* [[5. Use AT Command>>path:#H5.UseATCommand]]
55 -** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 -* [[6. FAQ>>path:#H6.FAQ]]
57 -** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 -* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 -** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 -* [[8. Order Info>>path:#H8.OrderInfo]]
61 -* [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 -* [[10. ​Support>>path:#H10.A0200BSupport]]
10 +{{toc/}}
63 63  
64 64  
65 65  
66 66  
15 +
16 +
67 67  = 1. Introduction =
68 68  
69 69  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
70 70  
71 -(((
72 -
73 73  
22 +(((
74 74  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
75 75  )))
76 76  
... ... @@ -95,9 +95,9 @@
95 95  
96 96  
97 97  
98 -
99 99  == ​1.2 Features ==
100 100  
49 +
101 101  * LoRaWAN 1.0.3 Class A
102 102  * Ultra-low power consumption
103 103  * Monitor soil pH with temperature compensation.
... ... @@ -112,9 +112,6 @@
112 112  * IP68 rate for the Sensor Probe
113 113  * 8500mAh Battery for long term use
114 114  
115 -
116 -
117 -
118 118  == 1.3 Probe Specification ==
119 119  
120 120  
... ... @@ -127,7 +127,6 @@
127 127  * IP68 Protection
128 128  * Length: 3.5 meters
129 129  
130 -
131 131  (% style="color:#4f81bd" %)**Soil Temperature:**
132 132  
133 133  * Range -40℃~85℃
... ... @@ -136,37 +136,34 @@
136 136  * IP68 Protection
137 137  * Length: 3.5 meters
138 138  
139 -
140 -
141 -
142 142  == 1.4 ​Applications ==
143 143  
86 +
144 144  * Smart Agriculture
145 145  
146 -
147 -
148 -
149 149  == 1.5 Pin mapping and power on ==
150 150  
91 +
151 151  [[image:1654592472094-134.png]]
152 152  
153 153  
154 -
155 155  = 2. Configure LSPH01 to connect to LoRaWAN network =
156 156  
157 157  == 2.1 How it works ==
158 158  
99 +
159 159  (((
160 160  The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
161 161  )))
162 162  
163 163  (((
164 -In case you cant set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
105 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
165 165  )))
166 166  
167 167  
168 168  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
169 169  
111 +
170 170  (((
171 171  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
172 172  )))
... ... @@ -191,10 +191,10 @@
191 191  Each LSPH01 is shipped with a sticker with the default device EUI as below:
192 192  )))
193 193  
194 -[[image:image-20220607170145-1.jpeg]]
136 +[[image:image-20230426084737-1.png||height="246" width="530"]](% style="display:none" %)
195 195  
138 +(% style="display:none" %) (%%)
196 196  
197 -
198 198  You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot:
199 199  
200 200  
... ... @@ -232,14 +232,16 @@
232 232  
233 233  (((
234 234  (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
177 +
178 +
235 235  )))
236 236  
237 237  [[image:1654592697690-910.png]]
238 238  
239 239  
240 -
241 241  == 2.3 ​Uplink Payload ==
242 242  
186 +
243 243  (((
244 244  LSPH01 will uplink payload via LoRaWAN with below payload format: 
245 245  )))
... ... @@ -252,14 +252,12 @@
252 252  Normal uplink payload:
253 253  )))
254 254  
255 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
256 -|=(% style="width: 62.5px;" %)(((
257 -**Size (bytes)**
258 -)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1**
199 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:470px" %)
200 +|=(% style="width: 60px;background-color:#D9E2F3;color:#0070C0" %)(((
201 +**Size(bytes)**
202 +)))|=(% style="width: 30px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 70px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 60px;background-color:#D9E2F3;color:#0070C0" %)**2**|=(% style="width: 70px;background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**1**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**1**
259 259  |(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)(((
260 -[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
261 -
262 -[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
204 +[[Temperature (Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
263 263  )))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
264 264  [[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
265 265  )))|Reserve|(((
... ... @@ -269,7 +269,6 @@
269 269  [[image:1654592721645-318.png]]
270 270  
271 271  
272 -
273 273  === 2.3.1 Battery Info ===
274 274  
275 275  
... ... @@ -280,9 +280,9 @@
280 280  Ex2: 0x0B49 = 2889mV
281 281  
282 282  
283 -
284 284  === 2.3.2 DS18B20 Temperature sensor ===
285 285  
226 +
286 286  This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
287 287  
288 288  
... ... @@ -293,9 +293,9 @@
293 293  If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
294 294  
295 295  
296 -
297 297  === 2.3.3 Soil pH ===
298 298  
239 +
299 299  Range: 0 ~~ 14 pH
300 300  
301 301  **Example:**
... ... @@ -303,9 +303,9 @@
303 303  (% style="color:#037691" %)** 0x02B7(H) = 695(D) = 6.95pH**
304 304  
305 305  
306 -
307 307  === 2.3.4 Soil Temperature ===
308 308  
249 +
309 309  Get Soil Temperature 
310 310  
311 311  
... ... @@ -316,9 +316,9 @@
316 316  If payload is: **FF3FH** :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
317 317  
318 318  
319 -
320 320  === 2.3.5 Interrupt Pin ===
321 321  
262 +
322 322  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
323 323  
324 324  
... ... @@ -329,9 +329,9 @@
329 329  0x01: Interrupt Uplink Packet.
330 330  
331 331  
332 -
333 333  === 2.3.6 Message Type ===
334 334  
275 +
335 335  (((
336 336  For a normal uplink payload, the message type is always 0x01.
337 337  )))
... ... @@ -341,17 +341,15 @@
341 341  )))
342 342  
343 343  
344 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:499px" %)
285 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:496px" %)
345 345  |=(% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload**
346 346  |(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
347 347  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
348 348  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
349 349  
350 -
351 -
352 -
353 353  === 2.3.7 Decode payload in The Things Network ===
354 354  
293 +
355 355  While using TTN network, you can add the payload format to decode the payload.
356 356  
357 357  
... ... @@ -362,19 +362,19 @@
362 362  )))
363 363  
364 364  (((
365 -LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
304 +LSPH01 TTN Payload Decoder:  [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
366 366  )))
367 367  
368 368  
369 -
370 370  == 2.4 Uplink Interval ==
371 371  
310 +
372 372  The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
373 373  
374 374  
375 -
376 376  == 2.5 ​Show Data in DataCake IoT Server ==
377 377  
316 +
378 378  (((
379 379  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
380 380  )))
... ... @@ -405,7 +405,6 @@
405 405  [[image:1654592819047-535.png]]
406 406  
407 407  
408 -
409 409  [[image:1654592833877-762.png]]
410 410  
411 411  
... ... @@ -417,7 +417,7 @@
417 417  )))
418 418  
419 419  (((
420 -Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
358 +Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
421 421  )))
422 422  
423 423  
... ... @@ -435,11 +435,11 @@
435 435  [[image:1654592917530-261.png]]
436 436  
437 437  
438 -
439 439  == 2.6 Installation and Maintain ==
440 440  
441 441  === 2.6.1 Before measurement ===
442 442  
380 +
443 443  (((
444 444  (((
445 445  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
... ... @@ -447,7 +447,6 @@
447 447  )))
448 448  
449 449  
450 -
451 451  === 2.6.2 Measurement ===
452 452  
453 453  
... ... @@ -457,6 +457,8 @@
457 457  
458 458  (((
459 459  [[image:1654592946732-634.png]]
397 +
398 +
460 460  )))
461 461  
462 462  (((
... ... @@ -468,7 +468,7 @@
468 468  )))
469 469  
470 470  (((
471 -Slowly insert the probe to the measure point. Dont use large force which will break the probe. Make sure not shake when inserting.
410 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting.
472 472  )))
473 473  
474 474  (((
... ... @@ -492,9 +492,9 @@
492 492  )))
493 493  
494 494  
495 -
496 496  === 2.6.3 Maintain Probe ===
497 497  
436 +
498 498  1. (((
499 499  pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
500 500  )))
... ... @@ -519,6 +519,7 @@
519 519  
520 520  == 2.7 Calibration ==
521 521  
461 +
522 522  (((
523 523  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
524 524  )))
... ... @@ -532,21 +532,16 @@
532 532  
533 533  (% style="color:#037691" %)**Calibration Payload**
534 534  
535 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
536 -|=(% style="width: 62.5px;" %)(((
475 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:500px" %)
476 +|=(% style="width: 60px;" %)(((
537 537  **Size (bytes)**
538 -)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1**
478 +)))|=(% style="width: 100px;" %)**1**|=(% style="width: 100px;" %)**1**|=(% style="width: 100px;" %)**1**|=(% style="width: 50px;" %)**7**|=(% style="width: 90px;" %)**1**
539 539  |**Value**|(((
540 -PH4
541 -
542 -Calibrate value
480 +PH4 Calibrate value
543 543  )))|PH6.86 Calibrate value|(((
544 -PH9.18
545 -
546 -Calibrate value
482 +PH9.18 Calibrate value
547 547  )))|Reserve|(((
548 548  [[Message Type>>||anchor="H2.3.6MessageType"]]
549 -
550 550  Always 0x03
551 551  )))
552 552  
... ... @@ -558,10 +558,9 @@
558 558  * Reply to the confirmation package: 14 01
559 559  * Reply to non-confirmed packet: 14 00
560 560  
561 -
562 -
563 563  == 2.8 Frequency Plans ==
564 564  
498 +
565 565  (((
566 566  The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
567 567  )))
... ... @@ -569,6 +569,7 @@
569 569  
570 570  === 2.8.1 EU863-870 (EU868) ===
571 571  
506 +
572 572  (((
573 573  (% style="color:blue" %)**Uplink:**
574 574  )))
... ... @@ -626,9 +626,9 @@
626 626  )))
627 627  
628 628  
629 -
630 630  === 2.8.2 US902-928(US915) ===
631 631  
566 +
632 632  (((
633 633  Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
634 634  )))
... ... @@ -642,11 +642,11 @@
642 642  )))
643 643  
644 644  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
645 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
580 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
646 646  
647 -
648 648  === 2.8.3 CN470-510 (CN470) ===
649 649  
584 +
650 650  (((
651 651  Used in China, Default use CHE=1
652 652  )))
... ... @@ -732,9 +732,9 @@
732 732  )))
733 733  
734 734  
735 -
736 736  === 2.8.4 AU915-928(AU915) ===
737 737  
672 +
738 738  (((
739 739  Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
740 740  )))
... ... @@ -752,10 +752,11 @@
752 752  )))
753 753  
754 754  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
755 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
690 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
756 756  
757 757  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
758 758  
694 +
759 759  (((
760 760  (% style="color:blue" %)**Default Uplink channel:**
761 761  )))
... ... @@ -861,9 +861,9 @@
861 861  )))
862 862  
863 863  
864 -
865 865  === 2.8.6 KR920-923 (KR920) ===
866 866  
802 +
867 867  (((
868 868  (% style="color:blue" %)**Default channel:**
869 869  )))
... ... @@ -933,9 +933,9 @@
933 933  )))
934 934  
935 935  
936 -
937 937  === 2.8.7 IN865-867 (IN865) ===
938 938  
874 +
939 939  (((
940 940  (% style="color:blue" %)**Uplink:**
941 941  )))
... ... @@ -969,9 +969,9 @@
969 969  )))
970 970  
971 971  
972 -
973 973  == 2.9 LED Indicator ==
974 974  
910 +
975 975  The LSPH01 has an internal LED which is to show the status of different state.
976 976  
977 977  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
... ... @@ -980,17 +980,14 @@
980 980  == 2.10 ​Firmware Change Log ==
981 981  
982 982  
983 -**Firmware download link:**
919 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]]
984 984  
985 -[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
986 -
987 -
988 988  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
989 989  
990 990  
991 -
992 992  = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
993 993  
926 +
994 994  (((
995 995  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
996 996  )))
... ... @@ -1022,7 +1022,7 @@
1022 1022  )))
1023 1023  
1024 1024  (((
1025 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
958 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1026 1026  )))
1027 1027  
1028 1028  (((
... ... @@ -1038,9 +1038,9 @@
1038 1038  )))
1039 1039  
1040 1040  
1041 -
1042 1042  == 3.1 Set Transmit Interval Time ==
1043 1043  
976 +
1044 1044  Feature: Change LoRaWAN End Node Transmit Interval.
1045 1045  
1046 1046  (% style="color:#037691" %)**AT Command: AT+TDC**
... ... @@ -1048,7 +1048,6 @@
1048 1048  [[image:image-20220607171554-8.png]]
1049 1049  
1050 1050  
1051 -
1052 1052  (((
1053 1053  (% style="color:#037691" %)**Downlink Command: 0x01**
1054 1054  )))
... ... @@ -1058,14 +1058,14 @@
1058 1058  )))
1059 1059  
1060 1060  (((
1061 -If the downlink payload=0100003C, it means set the END Nodes Transmit Interval to 0x00003C=60(S), while type code is 01.
993 +If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
1062 1062  )))
1063 1063  
1064 1064  * (((
1065 -Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
997 +Example 1: Downlink Payload: 0100001E  ~/~/ Set Transmit Interval (TDC) = 30 seconds
1066 1066  )))
1067 1067  * (((
1068 -Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1000 +Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
1069 1069  
1070 1070  
1071 1071  
... ... @@ -1073,6 +1073,7 @@
1073 1073  
1074 1074  == 3.2 Set Interrupt Mode ==
1075 1075  
1008 +
1076 1076  Feature, Set Interrupt mode for GPIO_EXIT.
1077 1077  
1078 1078  (% style="color:#037691" %)**AT Command: AT+INTMOD**
... ... @@ -1093,10 +1093,10 @@
1093 1093  )))
1094 1094  
1095 1095  * (((
1096 -Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1029 +Example 1: Downlink Payload: 06000000  ~/~/ Turn off interrupt mode
1097 1097  )))
1098 1098  * (((
1099 -Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1032 +Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
1100 1100  )))
1101 1101  
1102 1102  (((
... ... @@ -1107,12 +1107,13 @@
1107 1107  
1108 1108  == 3.3 Calibrate Sensor ==
1109 1109  
1043 +
1110 1110  Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
1111 1111  
1112 1112  
1113 -
1114 1114  == 3.4 Get Firmware Version Info ==
1115 1115  
1049 +
1116 1116  Feature: use downlink to get firmware version.
1117 1117  
1118 1118  (% style="color:#037691" %)**Downlink Command: 0x26**
... ... @@ -1132,11 +1132,9 @@
1132 1132  )))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
1133 1133  |**Value**|Software Type|(((
1134 1134  Frequency
1135 -
1136 1136  Band
1137 1137  )))|Sub-band|(((
1138 1138  Firmware
1139 -
1140 1140  Version
1141 1141  )))|Sensor Type|Reserve|(((
1142 1142  [[Message Type>>||anchor="H2.3.6MessageType"]]
... ... @@ -1143,10 +1143,10 @@
1143 1143  Always 0x02
1144 1144  )))
1145 1145  
1146 -**Software Type**: Always 0x03 for LSPH01
1078 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01
1147 1147  
1148 1148  
1149 -**Frequency Band**:
1081 +(% style="color:#037691" %)**Frequency Band**:
1150 1150  
1151 1151  *0x01: EU868
1152 1152  
... ... @@ -1169,13 +1169,13 @@
1169 1169  *0xa0: AS923-3
1170 1170  
1171 1171  
1172 -**Sub-Band**: value 0x00 ~~ 0x08
1104 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08
1173 1173  
1174 1174  
1175 -**Firmware Version**: 0x0100, Means: v1.0.0 version
1107 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
1176 1176  
1177 1177  
1178 -**Sensor Type**:
1110 +(% style="color:#037691" %)**Sensor Type**:
1179 1179  
1180 1180  0x01: LSE01
1181 1181  
... ... @@ -1192,111 +1192,25 @@
1192 1192  0x07: LDDS12
1193 1193  
1194 1194  
1127 += 4. Battery & Power Consumption =
1195 1195  
1196 -= 4. Battery & How to replace =
1197 1197  
1198 -== 4.1 Battery Type ==
1130 +LSPH01 uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
1199 1199  
1200 -(((
1201 -LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1202 -)))
1132 +[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
1203 1203  
1204 -(((
1205 -The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
1206 -)))
1207 1207  
1208 -[[image:1654593587246-335.png]]
1209 -
1210 -
1211 -Minimum Working Voltage for the LSPH01:
1212 -
1213 -LSPH01:  2.45v ~~ 3.6v
1214 -
1215 -
1216 -
1217 -== 4.2 Replace Battery ==
1218 -
1219 -(((
1220 -Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
1221 -)))
1222 -
1223 -(((
1224 -And make sure the positive and negative pins match.
1225 -)))
1226 -
1227 -
1228 -
1229 -== 4.3 Power Consumption Analyze ==
1230 -
1231 -(((
1232 -Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
1233 -)))
1234 -
1235 -(((
1236 -Instruction to use as below:
1237 -)))
1238 -
1239 -
1240 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1241 -
1242 -[[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1243 -
1244 -
1245 -**Step 2**: Open it and choose
1246 -
1247 -* Product Model
1248 -* Uplink Interval
1249 -* Working Mode
1250 -
1251 -And the Life expectation in difference case will be shown on the right.
1252 -
1253 -[[image:1654593605679-189.png]]
1254 -
1255 -
1256 -The battery related documents as below:
1257 -
1258 -* (((
1259 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1260 -)))
1261 -* (((
1262 -[[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1263 -)))
1264 -* (((
1265 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1266 -)))
1267 -
1268 -[[image:image-20220607172042-11.png]]
1269 -
1270 -
1271 -
1272 -=== 4.3.1 ​Battery Note ===
1273 -
1274 -(((
1275 -The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
1276 -)))
1277 -
1278 -
1279 -
1280 -=== ​4.3.2 Replace the battery ===
1281 -
1282 -(((
1283 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
1284 -)))
1285 -
1286 -(((
1287 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1288 -)))
1289 -
1290 -
1291 -
1292 1292  = 5. Use AT Command =
1293 1293  
1294 1294  == 5.1 Access AT Commands ==
1295 1295  
1139 +
1296 1296  LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
1297 1297  
1142 +
1298 1298  [[image:1654593668970-604.png]]
1299 1299  
1145 +
1300 1300  **Connection:**
1301 1301  
1302 1302  (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
... ... @@ -1320,6 +1320,7 @@
1320 1320  
1321 1321  == 6.1 How to change the LoRa Frequency Bands/Region ==
1322 1322  
1169 +
1323 1323  You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1324 1324  When downloading the images, choose the required image file for download. ​
1325 1325  
... ... @@ -1326,14 +1326,15 @@
1326 1326  
1327 1327  = 7. Trouble Shooting =
1328 1328  
1329 -== 7.1 AT Commands input doesnt work ==
1176 +== 7.1 AT Commands input doesn't work ==
1330 1330  
1331 -In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1332 1332  
1179 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1333 1333  
1334 1334  
1335 1335  = 8. Order Info =
1336 1336  
1184 +
1337 1337  Part Number: (% style="color:blue" %)**LSPH01-XX**
1338 1338  
1339 1339  
... ... @@ -1364,7 +1364,6 @@
1364 1364  
1365 1365  = 10. ​Support =
1366 1366  
1215 +
1367 1367  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1368 1368  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
1369 -
1370 -
image-20230426084737-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +190.0 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0