Changes for page LSPH01 -- LoRaWAN Soil pH Sensor User Manual
Last modified by Xiaoling on 2025/04/25 14:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,62 +4,7 @@ 4 4 5 5 6 6 7 -**Contents:** 8 8 9 -* [[1. Introduction>>path:#H1.Introduction]] 10 -** [[1.1 What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]] 11 -** [[1.2 Features>>path:#H200B1.2Features]] 12 -** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]] 13 -** [[1.4 Applications>>path:#H1.4200BApplications]] 14 -** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]] 15 -* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]] 16 -** [[2.1 How it works>>path:#H2.1Howitworks]] 17 -** [[2.2 Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]] 18 -** [[2.3 Uplink Payload>>path:#H2.3200BUplinkPayload]] 19 -*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]] 20 -*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]] 21 -*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]] 22 -*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]] 23 -*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]] 24 -*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]] 25 -*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]] 26 -** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]] 27 -** [[2.5 Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]] 28 -** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]] 29 -*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]] 30 -*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]] 31 -*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]] 32 -** [[2.7 Calibration>>path:#H2.7Calibration]] 33 -** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]] 34 -*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]] 35 -*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]] 36 -*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]] 37 -*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]] 38 -*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]] 39 -*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]] 40 -*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]] 41 -** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]] 42 -** [[2.10 Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]] 43 -* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]] 44 -** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]] 45 -** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]] 46 -** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]] 47 -** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]] 48 -* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]] 49 -** [[4.1 Battery Type>>path:#H4.1BatteryType]] 50 -** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]] 51 -** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]] 52 -*** [[4.3.1 Battery Note>>path:#H4.3.1200BBatteryNote]] 53 -*** [[4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]] 54 -* [[5. Use AT Command>>path:#H5.UseATCommand]] 55 -** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]] 56 -* [[6. FAQ>>path:#H6.FAQ]] 57 -** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]] 58 -* [[7. Trouble Shooting>>path:#H7.TroubleShooting]] 59 -** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]] 60 -* [[8. Order Info>>path:#H8.OrderInfo]] 61 -* [[9. Packing Info>>path:#H9.200BPackingInfo]] 62 -* [[10. Support>>path:#H10.A0200BSupport]] 63 63 64 64 65 65 ... ... @@ -66,11 +66,29 @@ 66 66 67 67 68 68 14 + 15 + 16 +**Table of Contents:** 17 + 18 +{{toc/}} 19 + 20 + 21 + 22 + 23 + 24 + 25 + 26 + 27 + 28 + 69 69 = 1. Introduction = 70 70 31 + 71 71 == 1.1 What is LoRaWAN Soil pH Sensor == 72 72 73 73 ((( 35 + 36 + 74 74 The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof. 75 75 ))) 76 76 ... ... @@ -98,6 +98,7 @@ 98 98 99 99 == 1.2 Features == 100 100 64 + 101 101 * LoRaWAN 1.0.3 Class A 102 102 * Ultra-low power consumption 103 103 * Monitor soil pH with temperature compensation. ... ... @@ -114,6 +114,8 @@ 114 114 115 115 116 116 81 + 82 + 117 117 == 1.3 Probe Specification == 118 118 119 119 ... ... @@ -136,14 +136,19 @@ 136 136 137 137 138 138 105 + 106 + 139 139 == 1.4 Applications == 140 140 109 + 141 141 * Smart Agriculture 142 142 143 143 144 144 114 + 145 145 == 1.5 Pin mapping and power on == 146 146 117 + 147 147 [[image:1654592472094-134.png]] 148 148 149 149 ... ... @@ -150,19 +150,23 @@ 150 150 151 151 = 2. Configure LSPH01 to connect to LoRaWAN network = 152 152 124 + 153 153 == 2.1 How it works == 154 154 127 + 155 155 ((( 156 156 The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 157 157 ))) 158 158 159 159 ((( 160 -In case you can ’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.133 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01. 161 161 ))) 162 162 163 163 137 + 164 164 == 2.2 Quick guide to connect to LoRaWAN server (OTAA) == 165 165 140 + 166 166 ((( 167 167 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example. 168 168 ))) ... ... @@ -169,10 +169,14 @@ 169 169 170 170 ((( 171 171 [[image:1654592492399-921.png]] 147 + 148 + 172 172 ))) 173 173 174 174 ((( 175 175 The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 153 + 154 + 176 176 ))) 177 177 178 178 ((( ... ... @@ -196,11 +196,13 @@ 196 196 [[image:1654592600093-601.png]] 197 197 198 198 178 + 199 199 **Add APP EUI and DEV EUI** 200 200 201 201 [[image:1654592619856-881.png]] 202 202 203 203 184 + 204 204 **Add APP EUI in the application** 205 205 206 206 [[image:1654592632656-512.png]] ... ... @@ -222,6 +222,8 @@ 222 222 223 223 ((( 224 224 (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel. 206 + 207 + 225 225 ))) 226 226 227 227 [[image:1654592697690-910.png]] ... ... @@ -230,6 +230,7 @@ 230 230 231 231 == 2.3 Uplink Payload == 232 232 216 + 233 233 ((( 234 234 LSPH01 will uplink payload via LoRaWAN with below payload format: 235 235 ))) ... ... @@ -273,6 +273,7 @@ 273 273 274 274 === 2.3.2 DS18B20 Temperature sensor === 275 275 260 + 276 276 This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature. 277 277 278 278 ... ... @@ -286,6 +286,7 @@ 286 286 287 287 === 2.3.3 Soil pH === 288 288 274 + 289 289 Range: 0 ~~ 14 pH 290 290 291 291 **Example:** ... ... @@ -296,6 +296,7 @@ 296 296 297 297 === 2.3.4 Soil Temperature === 298 298 285 + 299 299 Get Soil Temperature 300 300 301 301 ... ... @@ -309,6 +309,7 @@ 309 309 310 310 === 2.3.5 Interrupt Pin === 311 311 299 + 312 312 This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up. 313 313 314 314 ... ... @@ -322,6 +322,7 @@ 322 322 323 323 === 2.3.6 Message Type === 324 324 313 + 325 325 ((( 326 326 For a normal uplink payload, the message type is always 0x01. 327 327 ))) ... ... @@ -339,6 +339,8 @@ 339 339 340 340 341 341 331 + 332 + 342 342 === 2.3.7 Decode payload in The Things Network === 343 343 344 344 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -351,7 +351,7 @@ 351 351 ))) 352 352 353 353 ((( 354 -LSPH01 TTN Payload Decoder: agino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]345 +LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]] 355 355 ))) 356 356 357 357 ... ... @@ -358,6 +358,7 @@ 358 358 359 359 == 2.4 Uplink Interval == 360 360 352 + 361 361 The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] 362 362 363 363 ... ... @@ -364,6 +364,7 @@ 364 364 365 365 == 2.5 Show Data in DataCake IoT Server == 366 366 359 + 367 367 ((( 368 368 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 369 369 ))) ... ... @@ -406,7 +406,7 @@ 406 406 ))) 407 407 408 408 ((( 409 -Download Datacake decoder from: [[https:~~/~~/www.dr agino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]402 +Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]] 410 410 ))) 411 411 412 412 ... ... @@ -427,8 +427,10 @@ 427 427 428 428 == 2.6 Installation and Maintain == 429 429 423 + 430 430 === 2.6.1 Before measurement === 431 431 426 + 432 432 ((( 433 433 ((( 434 434 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. ... ... @@ -446,6 +446,8 @@ 446 446 447 447 ((( 448 448 [[image:1654592946732-634.png]] 444 + 445 + 449 449 ))) 450 450 451 451 ((( ... ... @@ -457,7 +457,7 @@ 457 457 ))) 458 458 459 459 ((( 460 -Slowly insert the probe to the measure point. Don ’t use large force which will break the probe. Make sure not shake when inserting.457 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting. 461 461 ))) 462 462 463 463 ((( ... ... @@ -484,6 +484,7 @@ 484 484 485 485 === 2.6.3 Maintain Probe === 486 486 484 + 487 487 1. ((( 488 488 pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 489 489 ))) ... ... @@ -508,6 +508,7 @@ 508 508 509 509 == 2.7 Calibration == 510 510 509 + 511 511 ((( 512 512 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 513 513 ))) ... ... @@ -539,6 +539,7 @@ 539 539 Always 0x03 540 540 ))) 541 541 541 + 542 542 User can also send 0x14 downlink command to poll the current calibration payload. 543 543 544 544 [[image:image-20220607171416-7.jpeg]] ... ... @@ -552,13 +552,16 @@ 552 552 553 553 == 2.8 Frequency Plans == 554 554 555 + 555 555 ((( 556 556 The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 557 557 ))) 558 558 559 559 561 + 560 560 === 2.8.1 EU863-870 (EU868) === 561 561 564 + 562 562 ((( 563 563 (% style="color:blue" %)**Uplink:** 564 564 ))) ... ... @@ -619,6 +619,7 @@ 619 619 620 620 === 2.8.2 US902-928(US915) === 621 621 625 + 622 622 ((( 623 623 Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document. 624 624 ))) ... ... @@ -632,13 +632,15 @@ 632 632 ))) 633 633 634 634 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 635 -* Use the Join successful sub-band if the server doesn ’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)639 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 636 636 637 637 638 638 639 639 644 + 640 640 === 2.8.3 CN470-510 (CN470) === 641 641 647 + 642 642 ((( 643 643 Used in China, Default use CHE=1 644 644 ))) ... ... @@ -727,6 +727,7 @@ 727 727 728 728 === 2.8.4 AU915-928(AU915) === 729 729 736 + 730 730 ((( 731 731 Frequency band as per definition in LoRaWAN 1.0.3 Regional document. 732 732 ))) ... ... @@ -744,12 +744,15 @@ 744 744 ))) 745 745 746 746 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 747 -* Use the Join successful sub-band if the server doesn ’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)754 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 748 748 749 749 750 750 758 + 759 + 751 751 === 2.8.5 AS920-923 & AS923-925 (AS923) === 752 752 762 + 753 753 ((( 754 754 (% style="color:blue" %)**Default Uplink channel:** 755 755 ))) ... ... @@ -858,6 +858,7 @@ 858 858 859 859 === 2.8.6 KR920-923 (KR920) === 860 860 871 + 861 861 ((( 862 862 (% style="color:blue" %)**Default channel:** 863 863 ))) ... ... @@ -930,6 +930,7 @@ 930 930 931 931 === 2.8.7 IN865-867 (IN865) === 932 932 944 + 933 933 ((( 934 934 (% style="color:blue" %)**Uplink:** 935 935 ))) ... ... @@ -966,6 +966,7 @@ 966 966 967 967 == 2.9 LED Indicator == 968 968 981 + 969 969 The LSPH01 has an internal LED which is to show the status of different state. 970 970 971 971 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. ... ... @@ -973,14 +973,14 @@ 973 973 974 974 975 975 976 -== 2.10 Firmware Change Log == 977 977 978 978 979 - **Firmwaredownloadlink:**991 +== 2.10 Firmware Change Log == 980 980 981 -[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]] 982 982 994 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]] 983 983 996 + 984 984 **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]] 985 985 986 986 ... ... @@ -1018,7 +1018,7 @@ 1018 1018 ))) 1019 1019 1020 1020 ((( 1021 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1034 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1022 1022 ))) 1023 1023 1024 1024 ((( ... ... @@ -1044,7 +1044,6 @@ 1044 1044 [[image:image-20220607171554-8.png]] 1045 1045 1046 1046 1047 - 1048 1048 ((( 1049 1049 (% style="color:#037691" %)**Downlink Command: 0x01** 1050 1050 ))) ... ... @@ -1073,7 +1073,7 @@ 1073 1073 1074 1074 (% style="color:#037691" %)**AT Command: AT+INTMOD** 1075 1075 1076 -[[image:image-2022060 7171716-9.png]]1088 +[[image:image-20220610105907-1.png]] 1077 1077 1078 1078 1079 1079 ((( ... ... @@ -1100,7 +1100,6 @@ 1100 1100 ))) 1101 1101 1102 1102 1103 - 1104 1104 == 3.3 Calibrate Sensor == 1105 1105 1106 1106 Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands ... ... @@ -1139,10 +1139,10 @@ 1139 1139 Always 0x02 1140 1140 ))) 1141 1141 1142 -**Software Type**: Always 0x03 for LSPH01 1153 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01 1143 1143 1144 1144 1145 -**Frequency Band**: 1156 +(% style="color:#037691" %)**Frequency Band**: 1146 1146 1147 1147 *0x01: EU868 1148 1148 ... ... @@ -1165,13 +1165,13 @@ 1165 1165 *0xa0: AS923-3 1166 1166 1167 1167 1168 -**Sub-Band**: value 0x00 ~~ 0x08 1179 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08 1169 1169 1170 1170 1171 -**Firmware Version**: 0x0100, Means: v1.0.0 version 1182 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 1172 1172 1173 1173 1174 -**Sensor Type**: 1185 +(% style="color:#037691" %)**Sensor Type**: 1175 1175 1176 1176 0x01: LSE01 1177 1177 ... ... @@ -1198,7 +1198,7 @@ 1198 1198 ))) 1199 1199 1200 1200 ((( 1201 -The discharge curve is not linear so can ’t simply use percentage to show the battery level. Below is the battery performance.1212 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 1202 1202 ))) 1203 1203 1204 1204 [[image:1654593587246-335.png]] ... ... @@ -1233,12 +1233,12 @@ 1233 1233 ))) 1234 1234 1235 1235 1236 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 1247 +(% style="color:#037691" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 1237 1237 1238 1238 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 1239 1239 1240 1240 1241 -**Step 2**: Open it and choose 1252 +(% style="color:#037691" %)**Step 2**(%%): Open it and choose 1242 1242 1243 1243 * Product Model 1244 1244 * Uplink Interval ... ... @@ -1252,13 +1252,13 @@ 1252 1252 The battery related documents as below: 1253 1253 1254 1254 * ((( 1255 -[[Battery Dimension>> url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],1266 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], 1256 1256 ))) 1257 1257 * ((( 1258 1258 [[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 1259 1259 ))) 1260 1260 * ((( 1261 -[[Lithium-ion Battery-Capacitor datasheet>> url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]1272 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]] 1262 1262 ))) 1263 1263 1264 1264 [[image:image-20220607172042-11.png]] ... ... @@ -1276,11 +1276,11 @@ 1276 1276 === 4.3.2 Replace the battery === 1277 1277 1278 1278 ((( 1279 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won ’t be voltage drop between battery and main board.1290 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 1280 1280 ))) 1281 1281 1282 1282 ((( 1283 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can ’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)1294 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 1284 1284 ))) 1285 1285 1286 1286 ... ... @@ -1322,9 +1322,9 @@ 1322 1322 1323 1323 = 7. Trouble Shooting = 1324 1324 1325 -== 7.1 AT Commands input doesn ’t work ==1336 +== 7.1 AT Commands input doesn't work == 1326 1326 1327 -In the case if user can see the console output but can ’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.1338 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1328 1328 1329 1329 1330 1330 ... ... @@ -1344,6 +1344,7 @@ 1344 1344 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1345 1345 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1346 1346 1358 + 1347 1347 = 9. Packing Info = 1348 1348 1349 1349 ... ... @@ -1358,6 +1358,7 @@ 1358 1358 * Package Size / pcs : cm 1359 1359 * Weight / pcs : g 1360 1360 1373 + 1361 1361 = 10. Support = 1362 1362 1363 1363 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.