From version < 85.34 >
edited by Xiaoling
on 2022/06/08 13:44
To version < 90.7 >
edited by Xiaoling
on 2022/06/25 16:55
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,7 +4,7 @@
4 4  
5 5  
6 6  
7 -**Contents:**
7 +**Table of Contents:**
8 8  
9 9  * [[1. Introduction>>path:#H1.Introduction]]
10 10  ** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
... ... @@ -61,16 +61,13 @@
61 61  * [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 62  * [[10. ​Support>>path:#H10.A0200BSupport]]
63 63  
64 -
65 -
66 -
67 -
68 -
69 69  = 1. Introduction =
70 70  
71 71  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
72 72  
73 73  (((
69 +
70 +
74 74  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
75 75  )))
76 76  
... ... @@ -112,8 +112,6 @@
112 112  * IP68 rate for the Sensor Probe
113 113  * 8500mAh Battery for long term use
114 114  
115 -
116 -
117 117  == 1.3 Probe Specification ==
118 118  
119 119  
... ... @@ -134,14 +134,10 @@
134 134  * IP68 Protection
135 135  * Length: 3.5 meters
136 136  
137 -
138 -
139 139  == 1.4 ​Applications ==
140 140  
141 141  * Smart Agriculture
142 142  
143 -
144 -
145 145  == 1.5 Pin mapping and power on ==
146 146  
147 147  [[image:1654592472094-134.png]]
... ... @@ -169,10 +169,14 @@
169 169  
170 170  (((
171 171  [[image:1654592492399-921.png]]
163 +
164 +
172 172  )))
173 173  
174 174  (((
175 175  The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
169 +
170 +
176 176  )))
177 177  
178 178  (((
... ... @@ -196,11 +196,13 @@
196 196  [[image:1654592600093-601.png]]
197 197  
198 198  
194 +
199 199  **Add APP EUI and DEV EUI**
200 200  
201 201  [[image:1654592619856-881.png]]
202 202  
203 203  
200 +
204 204  **Add APP EUI in the application**
205 205  
206 206  [[image:1654592632656-512.png]]
... ... @@ -337,8 +337,6 @@
337 337  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
338 338  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
339 339  
340 -
341 -
342 342  === 2.3.7 Decode payload in The Things Network ===
343 343  
344 344  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -547,6 +547,7 @@
547 547  * Reply to the confirmation package: 14 01
548 548  * Reply to non-confirmed packet: 14 00
549 549  
545 +
550 550  == 2.8 Frequency Plans ==
551 551  
552 552  (((
... ... @@ -634,6 +634,8 @@
634 634  
635 635  
636 636  
633 +
634 +
637 637  === 2.8.3 CN470-510 (CN470) ===
638 638  
639 639  (((
... ... @@ -745,6 +745,9 @@
745 745  
746 746  
747 747  
746 +
747 +
748 +
748 748  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
749 749  
750 750  (((
... ... @@ -970,6 +970,9 @@
970 970  
971 971  
972 972  
974 +
975 +
976 +
973 973  == 2.10 ​Firmware Change Log ==
974 974  
975 975  
... ... @@ -1041,7 +1041,6 @@
1041 1041  [[image:image-20220607171554-8.png]]
1042 1042  
1043 1043  
1044 -
1045 1045  (((
1046 1046  (% style="color:#037691" %)**Downlink Command: 0x01**
1047 1047  )))
... ... @@ -1070,7 +1070,7 @@
1070 1070  
1071 1071  (% style="color:#037691" %)**AT Command: AT+INTMOD**
1072 1072  
1073 -[[image:image-20220607171716-9.png]]
1076 +[[image:image-20220610105907-1.png]]
1074 1074  
1075 1075  
1076 1076  (((
... ... @@ -1136,10 +1136,10 @@
1136 1136  Always 0x02
1137 1137  )))
1138 1138  
1139 -**Software Type**: Always 0x03 for LSPH01
1142 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01
1140 1140  
1141 1141  
1142 -**Frequency Band**:
1145 +(% style="color:#037691" %)**Frequency Band**:
1143 1143  
1144 1144  *0x01: EU868
1145 1145  
... ... @@ -1162,13 +1162,13 @@
1162 1162  *0xa0: AS923-3
1163 1163  
1164 1164  
1165 -**Sub-Band**: value 0x00 ~~ 0x08
1168 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08
1166 1166  
1167 1167  
1168 -**Firmware Version**: 0x0100, Means: v1.0.0 version
1171 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
1169 1169  
1170 1170  
1171 -**Sensor Type**:
1174 +(% style="color:#037691" %)**Sensor Type**:
1172 1172  
1173 1173  0x01: LSE01
1174 1174  
... ... @@ -1195,7 +1195,7 @@
1195 1195  )))
1196 1196  
1197 1197  (((
1198 -The discharge curve is not linear so cant simply use percentage to show the battery level. Below is the battery performance.
1201 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1199 1199  )))
1200 1200  
1201 1201  [[image:1654593587246-335.png]]
... ... @@ -1230,12 +1230,12 @@
1230 1230  )))
1231 1231  
1232 1232  
1233 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1236 +(% style="color:red" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1234 1234  
1235 1235  [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1236 1236  
1237 1237  
1238 -**Step 2**: Open it and choose
1241 +(% style="color:#037691" %)**Step 2**(%%): Open it and choose
1239 1239  
1240 1240  * Product Model
1241 1241  * Uplink Interval
... ... @@ -1249,13 +1249,13 @@
1249 1249  The battery related documents as below:
1250 1250  
1251 1251  * (((
1252 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1255 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
1253 1253  )))
1254 1254  * (((
1255 1255  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1256 1256  )))
1257 1257  * (((
1258 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1261 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
1259 1259  )))
1260 1260  
1261 1261  [[image:image-20220607172042-11.png]]
... ... @@ -1273,7 +1273,7 @@
1273 1273  === ​4.3.2 Replace the battery ===
1274 1274  
1275 1275  (((
1276 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there wont be voltage drop between battery and main board.
1279 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
1277 1277  )))
1278 1278  
1279 1279  (((
... ... @@ -1319,9 +1319,9 @@
1319 1319  
1320 1320  = 7. Trouble Shooting =
1321 1321  
1322 -== 7.1 AT Commands input doesnt work ==
1325 +== 7.1 AT Commands input doesn't work ==
1323 1323  
1324 -In the case if user can see the console output but cant type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1327 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1325 1325  
1326 1326  
1327 1327  
... ... @@ -1341,6 +1341,9 @@
1341 1341  * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1342 1342  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1343 1343  
1347 +
1348 +
1349 +
1344 1344  = 9. ​Packing Info =
1345 1345  
1346 1346  
... ... @@ -1355,6 +1355,9 @@
1355 1355  * Package Size / pcs : cm
1356 1356  * Weight / pcs : g
1357 1357  
1364 +
1365 +
1366 +
1358 1358  = 10. ​Support =
1359 1359  
1360 1360  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
image-20220610105907-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +15.5 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0