<
From version < 85.32 >
edited by Xiaoling
on 2022/06/08 13:44
To version < 98.22 >
edited by Xiaoling
on 2022/10/27 14:59
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,72 +4,22 @@
4 4  
5 5  
6 6  
7 -**Contents:**
8 8  
9 -* [[1. Introduction>>path:#H1.Introduction]]
10 -** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 -** [[​1.2 Features>>path:#H200B1.2Features]]
12 -** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 -** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 -** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 -* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 -** [[2.1 How it works>>path:#H2.1Howitworks]]
17 -** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 -** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 -*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 -*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 -*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 -*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 -*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 -*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 -*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 -** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 -** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 -** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 -*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 -*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 -*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 -** [[2.7 Calibration>>path:#H2.7Calibration]]
33 -** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 -*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 -*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 -*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 -*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 -*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 -*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 -*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 -** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 -** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 -* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 -** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 -** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 -** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 -** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 -* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 -** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 -** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 -** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 -*** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 -*** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 -* [[5. Use AT Command>>path:#H5.UseATCommand]]
55 -** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 -* [[6. FAQ>>path:#H6.FAQ]]
57 -** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 -* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 -** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 -* [[8. Order Info>>path:#H8.OrderInfo]]
61 -* [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 -* [[10. ​Support>>path:#H10.A0200BSupport]]
8 +**Table of Contents:**
63 63  
10 +{{toc/}}
64 64  
65 65  
66 66  
67 67  
68 68  
16 +
69 69  = 1. Introduction =
70 70  
19 +
71 71  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
72 72  
22 +
73 73  (((
74 74  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
75 75  )))
... ... @@ -95,9 +95,9 @@
95 95  
96 96  
97 97  
98 -
99 99  == ​1.2 Features ==
100 100  
50 +
101 101  * LoRaWAN 1.0.3 Class A
102 102  * Ultra-low power consumption
103 103  * Monitor soil pH with temperature compensation.
... ... @@ -134,12 +134,18 @@
134 134  * IP68 Protection
135 135  * Length: 3.5 meters
136 136  
87 +
88 +
137 137  == 1.4 ​Applications ==
138 138  
91 +
139 139  * Smart Agriculture
140 140  
94 +
95 +
141 141  == 1.5 Pin mapping and power on ==
142 142  
98 +
143 143  [[image:1654592472094-134.png]]
144 144  
145 145  
... ... @@ -146,19 +146,23 @@
146 146  
147 147  = 2. Configure LSPH01 to connect to LoRaWAN network =
148 148  
105 +
149 149  == 2.1 How it works ==
150 150  
108 +
151 151  (((
152 152  The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
153 153  )))
154 154  
155 155  (((
156 -In case you cant set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
114 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
157 157  )))
158 158  
159 159  
118 +
160 160  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
161 161  
121 +
162 162  (((
163 163  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
164 164  )))
... ... @@ -165,10 +165,14 @@
165 165  
166 166  (((
167 167  [[image:1654592492399-921.png]]
128 +
129 +
168 168  )))
169 169  
170 170  (((
171 171  The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
134 +
135 +
172 172  )))
173 173  
174 174  (((
... ... @@ -192,11 +192,13 @@
192 192  [[image:1654592600093-601.png]]
193 193  
194 194  
159 +
195 195  **Add APP EUI and DEV EUI**
196 196  
197 197  [[image:1654592619856-881.png]]
198 198  
199 199  
165 +
200 200  **Add APP EUI in the application**
201 201  
202 202  [[image:1654592632656-512.png]]
... ... @@ -218,6 +218,8 @@
218 218  
219 219  (((
220 220  (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
187 +
188 +
221 221  )))
222 222  
223 223  [[image:1654592697690-910.png]]
... ... @@ -226,6 +226,7 @@
226 226  
227 227  == 2.3 ​Uplink Payload ==
228 228  
197 +
229 229  (((
230 230  LSPH01 will uplink payload via LoRaWAN with below payload format: 
231 231  )))
... ... @@ -238,14 +238,12 @@
238 238  Normal uplink payload:
239 239  )))
240 240  
241 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
242 -|=(% style="width: 62.5px;" %)(((
243 -**Size (bytes)**
244 -)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1**
210 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:470px" %)
211 +|=(% style="width: 60px;" %)(((
212 +**Size(bytes)**
213 +)))|=(% style="width: 30px;" %)**2**|=(% style="width: 70px;" %)**2**|=(% style="width: 50px;" %)**2**|=(% style="width: 60px;" %)**2**|=(% style="width: 70px;" %)**1**|=(% style="width: 50px;" %)**1**|=(% style="width: 80px;" %)**1**
245 245  |(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)(((
246 -[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
247 -
248 -[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
215 +[[Temperature (Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
249 249  )))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
250 250  [[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
251 251  )))|Reserve|(((
... ... @@ -269,6 +269,7 @@
269 269  
270 270  === 2.3.2 DS18B20 Temperature sensor ===
271 271  
239 +
272 272  This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
273 273  
274 274  
... ... @@ -282,6 +282,7 @@
282 282  
283 283  === 2.3.3 Soil pH ===
284 284  
253 +
285 285  Range: 0 ~~ 14 pH
286 286  
287 287  **Example:**
... ... @@ -292,6 +292,7 @@
292 292  
293 293  === 2.3.4 Soil Temperature ===
294 294  
264 +
295 295  Get Soil Temperature 
296 296  
297 297  
... ... @@ -305,6 +305,7 @@
305 305  
306 306  === 2.3.5 Interrupt Pin ===
307 307  
278 +
308 308  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
309 309  
310 310  
... ... @@ -318,6 +318,7 @@
318 318  
319 319  === 2.3.6 Message Type ===
320 320  
292 +
321 321  (((
322 322  For a normal uplink payload, the message type is always 0x01.
323 323  )))
... ... @@ -327,7 +327,7 @@
327 327  )))
328 328  
329 329  
330 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:499px" %)
302 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:496px" %)
331 331  |=(% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload**
332 332  |(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
333 333  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
... ... @@ -337,6 +337,7 @@
337 337  
338 338  === 2.3.7 Decode payload in The Things Network ===
339 339  
312 +
340 340  While using TTN network, you can add the payload format to decode the payload.
341 341  
342 342  
... ... @@ -347,7 +347,7 @@
347 347  )))
348 348  
349 349  (((
350 -LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
323 +LSPH01 TTN Payload Decoder:  [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
351 351  )))
352 352  
353 353  
... ... @@ -354,6 +354,7 @@
354 354  
355 355  == 2.4 Uplink Interval ==
356 356  
330 +
357 357  The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
358 358  
359 359  
... ... @@ -360,6 +360,7 @@
360 360  
361 361  == 2.5 ​Show Data in DataCake IoT Server ==
362 362  
337 +
363 363  (((
364 364  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
365 365  )))
... ... @@ -402,7 +402,7 @@
402 402  )))
403 403  
404 404  (((
405 -Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
380 +Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
406 406  )))
407 407  
408 408  
... ... @@ -423,8 +423,10 @@
423 423  
424 424  == 2.6 Installation and Maintain ==
425 425  
401 +
426 426  === 2.6.1 Before measurement ===
427 427  
404 +
428 428  (((
429 429  (((
430 430  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
... ... @@ -442,6 +442,8 @@
442 442  
443 443  (((
444 444  [[image:1654592946732-634.png]]
422 +
423 +
445 445  )))
446 446  
447 447  (((
... ... @@ -453,7 +453,7 @@
453 453  )))
454 454  
455 455  (((
456 -Slowly insert the probe to the measure point. Dont use large force which will break the probe. Make sure not shake when inserting.
435 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting.
457 457  )))
458 458  
459 459  (((
... ... @@ -480,6 +480,7 @@
480 480  
481 481  === 2.6.3 Maintain Probe ===
482 482  
462 +
483 483  1. (((
484 484  pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
485 485  )))
... ... @@ -504,6 +504,7 @@
504 504  
505 505  == 2.7 Calibration ==
506 506  
487 +
507 507  (((
508 508  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
509 509  )))
... ... @@ -517,21 +517,16 @@
517 517  
518 518  (% style="color:#037691" %)**Calibration Payload**
519 519  
520 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
521 -|=(% style="width: 62.5px;" %)(((
501 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:500px" %)
502 +|=(% style="width: 60px;" %)(((
522 522  **Size (bytes)**
523 -)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1**
504 +)))|=(% style="width: 100px;" %)**1**|=(% style="width: 100px;" %)**1**|=(% style="width: 100px;" %)**1**|=(% style="width: 50px;" %)**7**|=(% style="width: 90px;" %)**1**
524 524  |**Value**|(((
525 -PH4
526 -
527 -Calibrate value
506 +PH4 Calibrate value
528 528  )))|PH6.86 Calibrate value|(((
529 -PH9.18
530 -
531 -Calibrate value
508 +PH9.18 Calibrate value
532 532  )))|Reserve|(((
533 533  [[Message Type>>||anchor="H2.3.6MessageType"]]
534 -
535 535  Always 0x03
536 536  )))
537 537  
... ... @@ -543,15 +543,20 @@
543 543  * Reply to the confirmation package: 14 01
544 544  * Reply to non-confirmed packet: 14 00
545 545  
522 +
523 +
546 546  == 2.8 Frequency Plans ==
547 547  
526 +
548 548  (((
549 549  The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
550 550  )))
551 551  
552 552  
532 +
553 553  === 2.8.1 EU863-870 (EU868) ===
554 554  
535 +
555 555  (((
556 556  (% style="color:blue" %)**Uplink:**
557 557  )))
... ... @@ -612,6 +612,7 @@
612 612  
613 613  === 2.8.2 US902-928(US915) ===
614 614  
596 +
615 615  (((
616 616  Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
617 617  )))
... ... @@ -625,13 +625,13 @@
625 625  )))
626 626  
627 627  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
628 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
610 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
629 629  
630 630  
631 631  
632 -
633 633  === 2.8.3 CN470-510 (CN470) ===
634 634  
616 +
635 635  (((
636 636  Used in China, Default use CHE=1
637 637  )))
... ... @@ -720,6 +720,7 @@
720 720  
721 721  === 2.8.4 AU915-928(AU915) ===
722 722  
705 +
723 723  (((
724 724  Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
725 725  )))
... ... @@ -737,12 +737,13 @@
737 737  )))
738 738  
739 739  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
740 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
723 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
741 741  
742 742  
743 743  
744 744  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
745 745  
729 +
746 746  (((
747 747  (% style="color:blue" %)**Default Uplink channel:**
748 748  )))
... ... @@ -851,6 +851,7 @@
851 851  
852 852  === 2.8.6 KR920-923 (KR920) ===
853 853  
838 +
854 854  (((
855 855  (% style="color:blue" %)**Default channel:**
856 856  )))
... ... @@ -923,6 +923,7 @@
923 923  
924 924  === 2.8.7 IN865-867 (IN865) ===
925 925  
911 +
926 926  (((
927 927  (% style="color:blue" %)**Uplink:**
928 928  )))
... ... @@ -959,6 +959,7 @@
959 959  
960 960  == 2.9 LED Indicator ==
961 961  
948 +
962 962  The LSPH01 has an internal LED which is to show the status of different state.
963 963  
964 964  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
... ... @@ -969,11 +969,9 @@
969 969  == 2.10 ​Firmware Change Log ==
970 970  
971 971  
972 -**Firmware download link:**
959 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]]
973 973  
974 -[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
975 975  
976 -
977 977  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
978 978  
979 979  
... ... @@ -980,6 +980,7 @@
980 980  
981 981  = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
982 982  
968 +
983 983  (((
984 984  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
985 985  )))
... ... @@ -1011,7 +1011,7 @@
1011 1011  )))
1012 1012  
1013 1013  (((
1014 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1000 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1015 1015  )))
1016 1016  
1017 1017  (((
... ... @@ -1030,6 +1030,7 @@
1030 1030  
1031 1031  == 3.1 Set Transmit Interval Time ==
1032 1032  
1019 +
1033 1033  Feature: Change LoRaWAN End Node Transmit Interval.
1034 1034  
1035 1035  (% style="color:#037691" %)**AT Command: AT+TDC**
... ... @@ -1037,7 +1037,6 @@
1037 1037  [[image:image-20220607171554-8.png]]
1038 1038  
1039 1039  
1040 -
1041 1041  (((
1042 1042  (% style="color:#037691" %)**Downlink Command: 0x01**
1043 1043  )))
... ... @@ -1057,16 +1057,18 @@
1057 1057  Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1058 1058  
1059 1059  
1046 +
1060 1060  
1061 1061  )))
1062 1062  
1063 1063  == 3.2 Set Interrupt Mode ==
1064 1064  
1052 +
1065 1065  Feature, Set Interrupt mode for GPIO_EXIT.
1066 1066  
1067 1067  (% style="color:#037691" %)**AT Command: AT+INTMOD**
1068 1068  
1069 -[[image:image-20220607171716-9.png]]
1057 +[[image:image-20220610105907-1.png]]
1070 1070  
1071 1071  
1072 1072  (((
... ... @@ -1096,6 +1096,7 @@
1096 1096  
1097 1097  == 3.3 Calibrate Sensor ==
1098 1098  
1087 +
1099 1099  Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
1100 1100  
1101 1101  
... ... @@ -1102,6 +1102,7 @@
1102 1102  
1103 1103  == 3.4 Get Firmware Version Info ==
1104 1104  
1094 +
1105 1105  Feature: use downlink to get firmware version.
1106 1106  
1107 1107  (% style="color:#037691" %)**Downlink Command: 0x26**
... ... @@ -1121,11 +1121,9 @@
1121 1121  )))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
1122 1122  |**Value**|Software Type|(((
1123 1123  Frequency
1124 -
1125 1125  Band
1126 1126  )))|Sub-band|(((
1127 1127  Firmware
1128 -
1129 1129  Version
1130 1130  )))|Sensor Type|Reserve|(((
1131 1131  [[Message Type>>||anchor="H2.3.6MessageType"]]
... ... @@ -1132,11 +1132,13 @@
1132 1132  Always 0x02
1133 1133  )))
1134 1134  
1135 -**Software Type**: Always 0x03 for LSPH01
1136 1136  
1137 1137  
1138 -**Frequency Band**:
1125 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01
1139 1139  
1127 +
1128 +(% style="color:#037691" %)**Frequency Band**:
1129 +
1140 1140  *0x01: EU868
1141 1141  
1142 1142  *0x02: US915
... ... @@ -1158,13 +1158,13 @@
1158 1158  *0xa0: AS923-3
1159 1159  
1160 1160  
1161 -**Sub-Band**: value 0x00 ~~ 0x08
1151 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08
1162 1162  
1163 1163  
1164 -**Firmware Version**: 0x0100, Means: v1.0.0 version
1154 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
1165 1165  
1166 1166  
1167 -**Sensor Type**:
1157 +(% style="color:#037691" %)**Sensor Type**:
1168 1168  
1169 1169  0x01: LSE01
1170 1170  
... ... @@ -1184,14 +1184,18 @@
1184 1184  
1185 1185  = 4. Battery & How to replace =
1186 1186  
1177 +
1187 1187  == 4.1 Battery Type ==
1188 1188  
1180 +
1189 1189  (((
1190 1190  LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1191 1191  )))
1192 1192  
1193 1193  (((
1194 -The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
1186 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1187 +
1188 +
1195 1195  )))
1196 1196  
1197 1197  [[image:1654593587246-335.png]]
... ... @@ -1205,6 +1205,7 @@
1205 1205  
1206 1206  == 4.2 Replace Battery ==
1207 1207  
1202 +
1208 1208  (((
1209 1209  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
1210 1210  )))
... ... @@ -1217,6 +1217,7 @@
1217 1217  
1218 1218  == 4.3 Power Consumption Analyze ==
1219 1219  
1215 +
1220 1220  (((
1221 1221  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
1222 1222  )))
... ... @@ -1226,12 +1226,12 @@
1226 1226  )))
1227 1227  
1228 1228  
1229 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1225 +(% style="color:#037691" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1230 1230  
1231 1231  [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1232 1232  
1233 1233  
1234 -**Step 2**: Open it and choose
1230 +(% style="color:#037691" %)**Step 2**(%%): Open it and choose
1235 1235  
1236 1236  * Product Model
1237 1237  * Uplink Interval
... ... @@ -1245,13 +1245,13 @@
1245 1245  The battery related documents as below:
1246 1246  
1247 1247  * (((
1248 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1244 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
1249 1249  )))
1250 1250  * (((
1251 1251  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1252 1252  )))
1253 1253  * (((
1254 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1250 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
1255 1255  )))
1256 1256  
1257 1257  [[image:image-20220607172042-11.png]]
... ... @@ -1260,6 +1260,7 @@
1260 1260  
1261 1261  === 4.3.1 ​Battery Note ===
1262 1262  
1259 +
1263 1263  (((
1264 1264  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
1265 1265  )))
... ... @@ -1268,12 +1268,13 @@
1268 1268  
1269 1269  === ​4.3.2 Replace the battery ===
1270 1270  
1268 +
1271 1271  (((
1272 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there wont be voltage drop between battery and main board.
1270 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
1273 1273  )))
1274 1274  
1275 1275  (((
1276 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user cant find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1274 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1277 1277  )))
1278 1278  
1279 1279  
... ... @@ -1280,12 +1280,16 @@
1280 1280  
1281 1281  = 5. Use AT Command =
1282 1282  
1281 +
1283 1283  == 5.1 Access AT Commands ==
1284 1284  
1284 +
1285 1285  LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
1286 1286  
1287 +
1287 1287  [[image:1654593668970-604.png]]
1288 1288  
1290 +
1289 1289  **Connection:**
1290 1290  
1291 1291  (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
... ... @@ -1307,22 +1307,28 @@
1307 1307  
1308 1308  = 6. FAQ =
1309 1309  
1312 +
1310 1310  == 6.1 How to change the LoRa Frequency Bands/Region ==
1311 1311  
1315 +
1312 1312  You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1313 1313  When downloading the images, choose the required image file for download. ​
1314 1314  
1315 1315  
1320 +
1316 1316  = 7. Trouble Shooting =
1317 1317  
1318 -== 7.1 AT Commands input doesn’t work ==
1319 1319  
1320 -In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1324 +== 7.1 AT Commands input doesn't work ==
1321 1321  
1322 1322  
1327 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1323 1323  
1329 +
1330 +
1324 1324  = 8. Order Info =
1325 1325  
1333 +
1326 1326  Part Number: (% style="color:blue" %)**LSPH01-XX**
1327 1327  
1328 1328  
... ... @@ -1337,6 +1337,8 @@
1337 1337  * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1338 1338  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1339 1339  
1348 +
1349 +
1340 1340  = 9. ​Packing Info =
1341 1341  
1342 1342  
... ... @@ -1351,8 +1351,11 @@
1351 1351  * Package Size / pcs : cm
1352 1352  * Weight / pcs : g
1353 1353  
1364 +
1365 +
1354 1354  = 10. ​Support =
1355 1355  
1368 +
1356 1356  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1357 1357  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
1358 1358  
image-20220610105907-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +15.5 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0