<
From version < 85.32 >
edited by Xiaoling
on 2022/06/08 13:44
To version < 90.2 >
edited by Xiaoling
on 2022/06/25 16:48
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,7 +4,7 @@
4 4  
5 5  
6 6  
7 -**Contents:**
7 +**Table of Contents:**
8 8  
9 9  * [[1. Introduction>>path:#H1.Introduction]]
10 10  ** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
... ... @@ -62,15 +62,13 @@
62 62  * [[10. ​Support>>path:#H10.A0200BSupport]]
63 63  
64 64  
65 -
66 -
67 -
68 -
69 69  = 1. Introduction =
70 70  
71 71  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
72 72  
73 73  (((
70 +
71 +
74 74  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
75 75  )))
76 76  
... ... @@ -112,8 +112,6 @@
112 112  * IP68 rate for the Sensor Probe
113 113  * 8500mAh Battery for long term use
114 114  
115 -
116 -
117 117  == 1.3 Probe Specification ==
118 118  
119 119  
... ... @@ -165,10 +165,14 @@
165 165  
166 166  (((
167 167  [[image:1654592492399-921.png]]
164 +
165 +
168 168  )))
169 169  
170 170  (((
171 171  The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
170 +
171 +
172 172  )))
173 173  
174 174  (((
... ... @@ -192,11 +192,13 @@
192 192  [[image:1654592600093-601.png]]
193 193  
194 194  
195 +
195 195  **Add APP EUI and DEV EUI**
196 196  
197 197  [[image:1654592619856-881.png]]
198 198  
199 199  
201 +
200 200  **Add APP EUI in the application**
201 201  
202 202  [[image:1654592632656-512.png]]
... ... @@ -333,8 +333,6 @@
333 333  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
334 334  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
335 335  
336 -
337 -
338 338  === 2.3.7 Decode payload in The Things Network ===
339 339  
340 340  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -543,6 +543,8 @@
543 543  * Reply to the confirmation package: 14 01
544 544  * Reply to non-confirmed packet: 14 00
545 545  
546 +
547 +
546 546  == 2.8 Frequency Plans ==
547 547  
548 548  (((
... ... @@ -629,7 +629,6 @@
629 629  
630 630  
631 631  
632 -
633 633  === 2.8.3 CN470-510 (CN470) ===
634 634  
635 635  (((
... ... @@ -739,8 +739,6 @@
739 739  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
740 740  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
741 741  
742 -
743 -
744 744  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
745 745  
746 746  (((
... ... @@ -964,8 +964,6 @@
964 964  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
965 965  * Blink once when device transmit a packet.
966 966  
967 -
968 -
969 969  == 2.10 ​Firmware Change Log ==
970 970  
971 971  
... ... @@ -1037,7 +1037,6 @@
1037 1037  [[image:image-20220607171554-8.png]]
1038 1038  
1039 1039  
1040 -
1041 1041  (((
1042 1042  (% style="color:#037691" %)**Downlink Command: 0x01**
1043 1043  )))
... ... @@ -1066,7 +1066,7 @@
1066 1066  
1067 1067  (% style="color:#037691" %)**AT Command: AT+INTMOD**
1068 1068  
1069 -[[image:image-20220607171716-9.png]]
1065 +[[image:image-20220610105907-1.png]]
1070 1070  
1071 1071  
1072 1072  (((
... ... @@ -1191,7 +1191,7 @@
1191 1191  )))
1192 1192  
1193 1193  (((
1194 -The discharge curve is not linear so cant simply use percentage to show the battery level. Below is the battery performance.
1190 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1195 1195  )))
1196 1196  
1197 1197  [[image:1654593587246-335.png]]
... ... @@ -1245,13 +1245,13 @@
1245 1245  The battery related documents as below:
1246 1246  
1247 1247  * (((
1248 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1244 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
1249 1249  )))
1250 1250  * (((
1251 1251  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1252 1252  )))
1253 1253  * (((
1254 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1250 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
1255 1255  )))
1256 1256  
1257 1257  [[image:image-20220607172042-11.png]]
... ... @@ -1315,9 +1315,9 @@
1315 1315  
1316 1316  = 7. Trouble Shooting =
1317 1317  
1318 -== 7.1 AT Commands input doesnt work ==
1314 +== 7.1 AT Commands input doesn't work ==
1319 1319  
1320 -In the case if user can see the console output but cant type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1316 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1321 1321  
1322 1322  
1323 1323  
... ... @@ -1337,6 +1337,10 @@
1337 1337  * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1338 1338  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1339 1339  
1336 +
1337 +
1338 +
1339 +
1340 1340  = 9. ​Packing Info =
1341 1341  
1342 1342  
... ... @@ -1351,6 +1351,10 @@
1351 1351  * Package Size / pcs : cm
1352 1352  * Weight / pcs : g
1353 1353  
1354 +
1355 +
1356 +
1357 +
1354 1354  = 10. ​Support =
1355 1355  
1356 1356  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
image-20220610105907-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +15.5 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0