Changes for page LSPH01 -- LoRaWAN Soil pH Sensor User Manual
Last modified by Xiaoling on 2025/04/25 14:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,7 +4,7 @@ 4 4 5 5 6 6 7 -**Contents:** 7 +**Table of Contents:** 8 8 9 9 * [[1. Introduction>>path:#H1.Introduction]] 10 10 ** [[1.1 What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]] ... ... @@ -62,16 +62,13 @@ 62 62 * [[10. Support>>path:#H10.A0200BSupport]] 63 63 64 64 65 - 66 - 67 - 68 - 69 - 70 70 = 1. Introduction = 71 71 72 72 == 1.1 What is LoRaWAN Soil pH Sensor == 73 73 74 74 ((( 70 + 71 + 75 75 The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof. 76 76 ))) 77 77 ... ... @@ -113,7 +113,6 @@ 113 113 * IP68 rate for the Sensor Probe 114 114 * 8500mAh Battery for long term use 115 115 116 - 117 117 == 1.3 Probe Specification == 118 118 119 119 ... ... @@ -134,12 +134,10 @@ 134 134 * IP68 Protection 135 135 * Length: 3.5 meters 136 136 137 - 138 138 == 1.4 Applications == 139 139 140 140 * Smart Agriculture 141 141 142 - 143 143 == 1.5 Pin mapping and power on == 144 144 145 145 [[image:1654592472094-134.png]] ... ... @@ -167,10 +167,14 @@ 167 167 168 168 ((( 169 169 [[image:1654592492399-921.png]] 164 + 165 + 170 170 ))) 171 171 172 172 ((( 173 173 The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 170 + 171 + 174 174 ))) 175 175 176 176 ((( ... ... @@ -194,11 +194,13 @@ 194 194 [[image:1654592600093-601.png]] 195 195 196 196 195 + 197 197 **Add APP EUI and DEV EUI** 198 198 199 199 [[image:1654592619856-881.png]] 200 200 201 201 201 + 202 202 **Add APP EUI in the application** 203 203 204 204 [[image:1654592632656-512.png]] ... ... @@ -335,9 +335,6 @@ 335 335 |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]] 336 336 |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]] 337 337 338 - 339 - 340 - 341 341 === 2.3.7 Decode payload in The Things Network === 342 342 343 343 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -546,6 +546,8 @@ 546 546 * Reply to the confirmation package: 14 01 547 547 * Reply to non-confirmed packet: 14 00 548 548 546 + 547 + 549 549 == 2.8 Frequency Plans == 550 550 551 551 ((( ... ... @@ -632,8 +632,6 @@ 632 632 633 633 634 634 635 - 636 - 637 637 === 2.8.3 CN470-510 (CN470) === 638 638 639 639 ((( ... ... @@ -743,9 +743,6 @@ 743 743 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 744 744 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 745 745 746 - 747 - 748 - 749 749 === 2.8.5 AS920-923 & AS923-925 (AS923) === 750 750 751 751 ((( ... ... @@ -969,9 +969,6 @@ 969 969 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. 970 970 * Blink once when device transmit a packet. 971 971 972 - 973 - 974 - 975 975 == 2.10 Firmware Change Log == 976 976 977 977 ... ... @@ -1043,7 +1043,6 @@ 1043 1043 [[image:image-20220607171554-8.png]] 1044 1044 1045 1045 1046 - 1047 1047 ((( 1048 1048 (% style="color:#037691" %)**Downlink Command: 0x01** 1049 1049 ))) ... ... @@ -1072,7 +1072,7 @@ 1072 1072 1073 1073 (% style="color:#037691" %)**AT Command: AT+INTMOD** 1074 1074 1075 -[[image:image-2022060 7171716-9.png]]1065 +[[image:image-20220610105907-1.png]] 1076 1076 1077 1077 1078 1078 ((( ... ... @@ -1138,10 +1138,10 @@ 1138 1138 Always 0x02 1139 1139 ))) 1140 1140 1141 -**Software Type**: Always 0x03 for LSPH01 1131 +**(% style="color:#037691" %)Software Type**(%%): Always 0x03 for LSPH01 1142 1142 1143 1143 1144 -**Frequency Band**: 1134 +**(% style="color:#037691" %)Frequency Band**: 1145 1145 1146 1146 *0x01: EU868 1147 1147 ... ... @@ -1164,13 +1164,13 @@ 1164 1164 *0xa0: AS923-3 1165 1165 1166 1166 1167 -**Sub-Band**: value 0x00 ~~ 0x08 1157 +**(% style="color:#037691" %)Sub-Band**(%%): value 0x00 ~~ 0x08 1168 1168 1169 1169 1170 -**Firmware Version**: 0x0100, Means: v1.0.0 version 1160 +**(% style="color:#037691" %)Firmware Version**(%%): 0x0100, Means: v1.0.0 version 1171 1171 1172 1172 1173 -**Sensor Type**: 1163 +**(% style="color:#037691" %)Sensor Type**: 1174 1174 1175 1175 0x01: LSE01 1176 1176 ... ... @@ -1197,7 +1197,7 @@ 1197 1197 ))) 1198 1198 1199 1199 ((( 1200 -The discharge curve is not linear so can ’t simply use percentage to show the battery level. Below is the battery performance.1190 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 1201 1201 ))) 1202 1202 1203 1203 [[image:1654593587246-335.png]] ... ... @@ -1232,12 +1232,12 @@ 1232 1232 ))) 1233 1233 1234 1234 1235 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 1225 +**(% style="color:red" %)Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 1236 1236 1237 1237 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 1238 1238 1239 1239 1240 -**Step 2**: Open it and choose 1230 +**(% style="color:#037691" %)Step 2**(%%): Open it and choose 1241 1241 1242 1242 * Product Model 1243 1243 * Uplink Interval ... ... @@ -1251,13 +1251,13 @@ 1251 1251 The battery related documents as below: 1252 1252 1253 1253 * ((( 1254 -[[Battery Dimension>> url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],1244 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], 1255 1255 ))) 1256 1256 * ((( 1257 1257 [[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 1258 1258 ))) 1259 1259 * ((( 1260 -[[Lithium-ion Battery-Capacitor datasheet>> url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]1250 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]] 1261 1261 ))) 1262 1262 1263 1263 [[image:image-20220607172042-11.png]] ... ... @@ -1275,7 +1275,7 @@ 1275 1275 === 4.3.2 Replace the battery === 1276 1276 1277 1277 ((( 1278 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won ’t be voltage drop between battery and main board.1268 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 1279 1279 ))) 1280 1280 1281 1281 ((( ... ... @@ -1321,9 +1321,9 @@ 1321 1321 1322 1322 = 7. Trouble Shooting = 1323 1323 1324 -== 7.1 AT Commands input doesn ’t work ==1314 +== 7.1 AT Commands input doesn't work == 1325 1325 1326 -In the case if user can see the console output but can ’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.1316 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1327 1327 1328 1328 1329 1329 ... ... @@ -1344,6 +1344,9 @@ 1344 1344 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1345 1345 1346 1346 1337 + 1338 + 1339 + 1347 1347 = 9. Packing Info = 1348 1348 1349 1349 ... ... @@ -1359,6 +1359,9 @@ 1359 1359 * Weight / pcs : g 1360 1360 1361 1361 1355 + 1356 + 1357 + 1362 1362 = 10. Support = 1363 1363 1364 1364 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- image-20220610105907-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.5 KB - Content