Changes for page LSPH01 -- LoRaWAN Soil pH Sensor User Manual
Last modified by Xiaoling on 2025/04/25 14:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,7 +4,7 @@ 4 4 5 5 6 6 7 -**Contents:** 7 +**Table of Contents:** 8 8 9 9 * [[1. Introduction>>path:#H1.Introduction]] 10 10 ** [[1.1 What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]] ... ... @@ -61,12 +61,13 @@ 61 61 * [[9. Packing Info>>path:#H9.200BPackingInfo]] 62 62 * [[10. Support>>path:#H10.A0200BSupport]] 63 63 64 - 65 65 = 1. Introduction = 66 66 67 67 == 1.1 What is LoRaWAN Soil pH Sensor == 68 68 69 69 ((( 69 + 70 + 70 70 The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof. 71 71 ))) 72 72 ... ... @@ -108,9 +108,6 @@ 108 108 * IP68 rate for the Sensor Probe 109 109 * 8500mAh Battery for long term use 110 110 111 - 112 - 113 - 114 114 == 1.3 Probe Specification == 115 115 116 116 ... ... @@ -131,16 +131,10 @@ 131 131 * IP68 Protection 132 132 * Length: 3.5 meters 133 133 134 - 135 - 136 - 137 137 == 1.4 Applications == 138 138 139 139 * Smart Agriculture 140 140 141 - 142 - 143 - 144 144 == 1.5 Pin mapping and power on == 145 145 146 146 [[image:1654592472094-134.png]] ... ... @@ -168,10 +168,14 @@ 168 168 169 169 ((( 170 170 [[image:1654592492399-921.png]] 163 + 164 + 171 171 ))) 172 172 173 173 ((( 174 174 The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 169 + 170 + 175 175 ))) 176 176 177 177 ((( ... ... @@ -195,11 +195,13 @@ 195 195 [[image:1654592600093-601.png]] 196 196 197 197 194 + 198 198 **Add APP EUI and DEV EUI** 199 199 200 200 [[image:1654592619856-881.png]] 201 201 202 202 200 + 203 203 **Add APP EUI in the application** 204 204 205 205 [[image:1654592632656-512.png]] ... ... @@ -545,7 +545,6 @@ 545 545 * Reply to non-confirmed packet: 14 00 546 546 547 547 548 - 549 549 == 2.8 Frequency Plans == 550 550 551 551 ((( ... ... @@ -630,6 +630,7 @@ 630 630 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 631 631 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 632 632 630 + 633 633 === 2.8.3 CN470-510 (CN470) === 634 634 635 635 ((( ... ... @@ -739,6 +739,11 @@ 739 739 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 740 740 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 741 741 740 + 741 + 742 + 743 + 744 + 742 742 === 2.8.5 AS920-923 & AS923-925 (AS923) === 743 743 744 744 ((( ... ... @@ -962,6 +962,11 @@ 962 962 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. 963 963 * Blink once when device transmit a packet. 964 964 968 + 969 + 970 + 971 + 972 + 965 965 == 2.10 Firmware Change Log == 966 966 967 967 ... ... @@ -1033,7 +1033,6 @@ 1033 1033 [[image:image-20220607171554-8.png]] 1034 1034 1035 1035 1036 - 1037 1037 ((( 1038 1038 (% style="color:#037691" %)**Downlink Command: 0x01** 1039 1039 ))) ... ... @@ -1062,7 +1062,7 @@ 1062 1062 1063 1063 (% style="color:#037691" %)**AT Command: AT+INTMOD** 1064 1064 1065 -[[image:image-2022060 7171716-9.png]]1072 +[[image:image-20220610105907-1.png]] 1066 1066 1067 1067 1068 1068 ((( ... ... @@ -1128,10 +1128,10 @@ 1128 1128 Always 0x02 1129 1129 ))) 1130 1130 1131 -**Software Type**: Always 0x03 for LSPH01 1138 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01 1132 1132 1133 1133 1134 -**Frequency Band**: 1141 +(% style="color:#037691" %)**Frequency Band**: 1135 1135 1136 1136 *0x01: EU868 1137 1137 ... ... @@ -1154,13 +1154,13 @@ 1154 1154 *0xa0: AS923-3 1155 1155 1156 1156 1157 -**Sub-Band**: value 0x00 ~~ 0x08 1164 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08 1158 1158 1159 1159 1160 -**Firmware Version**: 0x0100, Means: v1.0.0 version 1167 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 1161 1161 1162 1162 1163 -**Sensor Type**: 1170 +(% style="color:#037691" %)**Sensor Type**: 1164 1164 1165 1165 0x01: LSE01 1166 1166 ... ... @@ -1187,7 +1187,7 @@ 1187 1187 ))) 1188 1188 1189 1189 ((( 1190 -The discharge curve is not linear so can ’t simply use percentage to show the battery level. Below is the battery performance.1197 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 1191 1191 ))) 1192 1192 1193 1193 [[image:1654593587246-335.png]] ... ... @@ -1222,12 +1222,12 @@ 1222 1222 ))) 1223 1223 1224 1224 1225 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 1232 +(% style="color:red" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 1226 1226 1227 1227 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 1228 1228 1229 1229 1230 -**Step 2**: Open it and choose 1237 +(% style="color:#037691" %)**Step 2**(%%): Open it and choose 1231 1231 1232 1232 * Product Model 1233 1233 * Uplink Interval ... ... @@ -1241,13 +1241,13 @@ 1241 1241 The battery related documents as below: 1242 1242 1243 1243 * ((( 1244 -[[Battery Dimension>> url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],1251 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], 1245 1245 ))) 1246 1246 * ((( 1247 1247 [[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 1248 1248 ))) 1249 1249 * ((( 1250 -[[Lithium-ion Battery-Capacitor datasheet>> url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]1257 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]] 1251 1251 ))) 1252 1252 1253 1253 [[image:image-20220607172042-11.png]] ... ... @@ -1265,7 +1265,7 @@ 1265 1265 === 4.3.2 Replace the battery === 1266 1266 1267 1267 ((( 1268 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won ’t be voltage drop between battery and main board.1275 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 1269 1269 ))) 1270 1270 1271 1271 ((( ... ... @@ -1311,9 +1311,9 @@ 1311 1311 1312 1312 = 7. Trouble Shooting = 1313 1313 1314 -== 7.1 AT Commands input doesn ’t work ==1321 +== 7.1 AT Commands input doesn't work == 1315 1315 1316 -In the case if user can see the console output but can ’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.1323 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1317 1317 1318 1318 1319 1319
- image-20220610105907-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.5 KB - Content