Changes for page LSPH01 -- LoRaWAN Soil pH Sensor User Manual
Last modified by Xiaoling on 2025/04/25 14:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,69 +4,36 @@ 4 4 5 5 6 6 7 -**Contents:** 8 8 9 -* [[1. Introduction>>path:#H1.Introduction]] 10 -** [[1.1 What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]] 11 -** [[1.2 Features>>path:#H200B1.2Features]] 12 -** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]] 13 -** [[1.4 Applications>>path:#H1.4200BApplications]] 14 -** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]] 15 -* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]] 16 -** [[2.1 How it works>>path:#H2.1Howitworks]] 17 -** [[2.2 Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]] 18 -** [[2.3 Uplink Payload>>path:#H2.3200BUplinkPayload]] 19 -*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]] 20 -*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]] 21 -*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]] 22 -*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]] 23 -*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]] 24 -*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]] 25 -*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]] 26 -** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]] 27 -** [[2.5 Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]] 28 -** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]] 29 -*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]] 30 -*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]] 31 -*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]] 32 -** [[2.7 Calibration>>path:#H2.7Calibration]] 33 -** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]] 34 -*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]] 35 -*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]] 36 -*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]] 37 -*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]] 38 -*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]] 39 -*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]] 40 -*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]] 41 -** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]] 42 -** [[2.10 Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]] 43 -* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]] 44 -** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]] 45 -** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]] 46 -** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]] 47 -** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]] 48 -* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]] 49 -** [[4.1 Battery Type>>path:#H4.1BatteryType]] 50 -** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]] 51 -** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]] 52 -*** [[4.3.1 Battery Note>>path:#H4.3.1200BBatteryNote]] 53 -*** [[4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]] 54 -* [[5. Use AT Command>>path:#H5.UseATCommand]] 55 -** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]] 56 -* [[6. FAQ>>path:#H6.FAQ]] 57 -** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]] 58 -* [[7. Trouble Shooting>>path:#H7.TroubleShooting]] 59 -** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]] 60 -* [[8. Order Info>>path:#H8.OrderInfo]] 61 -* [[9. Packing Info>>path:#H9.200BPackingInfo]] 62 -* [[10. Support>>path:#H10.A0200BSupport]] 63 63 64 64 10 + 11 + 12 + 13 + 14 + 15 + 16 +**Table of Contents:** 17 + 18 +{{toc/}} 19 + 20 + 21 + 22 + 23 + 24 + 25 + 26 + 27 + 28 + 65 65 = 1. Introduction = 66 66 31 + 67 67 == 1.1 What is LoRaWAN Soil pH Sensor == 68 68 69 69 ((( 35 + 36 + 70 70 The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof. 71 71 ))) 72 72 ... ... @@ -94,6 +94,7 @@ 94 94 95 95 == 1.2 Features == 96 96 64 + 97 97 * LoRaWAN 1.0.3 Class A 98 98 * Ultra-low power consumption 99 99 * Monitor soil pH with temperature compensation. ... ... @@ -111,6 +111,7 @@ 111 111 112 112 113 113 82 + 114 114 == 1.3 Probe Specification == 115 115 116 116 ... ... @@ -131,12 +131,21 @@ 131 131 * IP68 Protection 132 132 * Length: 3.5 meters 133 133 103 + 104 + 105 + 106 + 134 134 == 1.4 Applications == 135 135 109 + 136 136 * Smart Agriculture 137 137 112 + 113 + 114 + 138 138 == 1.5 Pin mapping and power on == 139 139 117 + 140 140 [[image:1654592472094-134.png]] 141 141 142 142 ... ... @@ -143,19 +143,23 @@ 143 143 144 144 = 2. Configure LSPH01 to connect to LoRaWAN network = 145 145 124 + 146 146 == 2.1 How it works == 147 147 127 + 148 148 ((( 149 149 The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 150 150 ))) 151 151 152 152 ((( 153 -In case you can ’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.133 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01. 154 154 ))) 155 155 156 156 137 + 157 157 == 2.2 Quick guide to connect to LoRaWAN server (OTAA) == 158 158 140 + 159 159 ((( 160 160 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example. 161 161 ))) ... ... @@ -162,10 +162,14 @@ 162 162 163 163 ((( 164 164 [[image:1654592492399-921.png]] 147 + 148 + 165 165 ))) 166 166 167 167 ((( 168 168 The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 153 + 154 + 169 169 ))) 170 170 171 171 ((( ... ... @@ -189,11 +189,13 @@ 189 189 [[image:1654592600093-601.png]] 190 190 191 191 178 + 192 192 **Add APP EUI and DEV EUI** 193 193 194 194 [[image:1654592619856-881.png]] 195 195 196 196 184 + 197 197 **Add APP EUI in the application** 198 198 199 199 [[image:1654592632656-512.png]] ... ... @@ -215,6 +215,8 @@ 215 215 216 216 ((( 217 217 (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel. 206 + 207 + 218 218 ))) 219 219 220 220 [[image:1654592697690-910.png]] ... ... @@ -223,6 +223,7 @@ 223 223 224 224 == 2.3 Uplink Payload == 225 225 216 + 226 226 ((( 227 227 LSPH01 will uplink payload via LoRaWAN with below payload format: 228 228 ))) ... ... @@ -266,6 +266,7 @@ 266 266 267 267 === 2.3.2 DS18B20 Temperature sensor === 268 268 260 + 269 269 This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature. 270 270 271 271 ... ... @@ -279,6 +279,7 @@ 279 279 280 280 === 2.3.3 Soil pH === 281 281 274 + 282 282 Range: 0 ~~ 14 pH 283 283 284 284 **Example:** ... ... @@ -289,6 +289,7 @@ 289 289 290 290 === 2.3.4 Soil Temperature === 291 291 285 + 292 292 Get Soil Temperature 293 293 294 294 ... ... @@ -302,6 +302,7 @@ 302 302 303 303 === 2.3.5 Interrupt Pin === 304 304 299 + 305 305 This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up. 306 306 307 307 ... ... @@ -315,6 +315,7 @@ 315 315 316 316 === 2.3.6 Message Type === 317 317 313 + 318 318 ((( 319 319 For a normal uplink payload, the message type is always 0x01. 320 320 ))) ... ... @@ -330,6 +330,10 @@ 330 330 |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]] 331 331 |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]] 332 332 329 + 330 + 331 + 332 + 333 333 === 2.3.7 Decode payload in The Things Network === 334 334 335 335 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -342,7 +342,7 @@ 342 342 ))) 343 343 344 344 ((( 345 -LSPH01 TTN Payload Decoder: agino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]345 +LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]] 346 346 ))) 347 347 348 348 ... ... @@ -349,12 +349,14 @@ 349 349 350 350 == 2.4 Uplink Interval == 351 351 352 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]] 353 353 353 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] 354 354 355 355 356 + 356 356 == 2.5 Show Data in DataCake IoT Server == 357 357 359 + 358 358 ((( 359 359 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 360 360 ))) ... ... @@ -397,7 +397,7 @@ 397 397 ))) 398 398 399 399 ((( 400 -Download Datacake decoder from: [[https:~~/~~/www.dr agino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]402 +Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]] 401 401 ))) 402 402 403 403 ... ... @@ -418,8 +418,10 @@ 418 418 419 419 == 2.6 Installation and Maintain == 420 420 423 + 421 421 === 2.6.1 Before measurement === 422 422 426 + 423 423 ((( 424 424 ((( 425 425 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. ... ... @@ -437,6 +437,8 @@ 437 437 438 438 ((( 439 439 [[image:1654592946732-634.png]] 444 + 445 + 440 440 ))) 441 441 442 442 ((( ... ... @@ -448,7 +448,7 @@ 448 448 ))) 449 449 450 450 ((( 451 -Slowly insert the probe to the measure point. Don ’t use large force which will break the probe. Make sure not shake when inserting.457 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting. 452 452 ))) 453 453 454 454 ((( ... ... @@ -475,6 +475,7 @@ 475 475 476 476 === 2.6.3 Maintain Probe === 477 477 484 + 478 478 1. ((( 479 479 pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 480 480 ))) ... ... @@ -499,6 +499,7 @@ 499 499 500 500 == 2.7 Calibration == 501 501 509 + 502 502 ((( 503 503 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 504 504 ))) ... ... @@ -530,6 +530,7 @@ 530 530 Always 0x03 531 531 ))) 532 532 541 + 533 533 User can also send 0x14 downlink command to poll the current calibration payload. 534 534 535 535 [[image:image-20220607171416-7.jpeg]] ... ... @@ -540,15 +540,19 @@ 540 540 541 541 542 542 552 + 543 543 == 2.8 Frequency Plans == 544 544 555 + 545 545 ((( 546 546 The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 547 547 ))) 548 548 549 549 561 + 550 550 === 2.8.1 EU863-870 (EU868) === 551 551 564 + 552 552 ((( 553 553 (% style="color:blue" %)**Uplink:** 554 554 ))) ... ... @@ -609,6 +609,7 @@ 609 609 610 610 === 2.8.2 US902-928(US915) === 611 611 625 + 612 612 ((( 613 613 Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document. 614 614 ))) ... ... @@ -622,10 +622,15 @@ 622 622 ))) 623 623 624 624 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 625 -* Use the Join successful sub-band if the server doesn ’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)639 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 626 626 641 + 642 + 643 + 644 + 627 627 === 2.8.3 CN470-510 (CN470) === 628 628 647 + 629 629 ((( 630 630 Used in China, Default use CHE=1 631 631 ))) ... ... @@ -714,6 +714,7 @@ 714 714 715 715 === 2.8.4 AU915-928(AU915) === 716 716 736 + 717 717 ((( 718 718 Frequency band as per definition in LoRaWAN 1.0.3 Regional document. 719 719 ))) ... ... @@ -731,10 +731,15 @@ 731 731 ))) 732 732 733 733 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 734 -* Use the Join successful sub-band if the server doesn ’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)754 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 735 735 756 + 757 + 758 + 759 + 736 736 === 2.8.5 AS920-923 & AS923-925 (AS923) === 737 737 762 + 738 738 ((( 739 739 (% style="color:blue" %)**Default Uplink channel:** 740 740 ))) ... ... @@ -843,6 +843,7 @@ 843 843 844 844 === 2.8.6 KR920-923 (KR920) === 845 845 871 + 846 846 ((( 847 847 (% style="color:blue" %)**Default channel:** 848 848 ))) ... ... @@ -915,6 +915,7 @@ 915 915 916 916 === 2.8.7 IN865-867 (IN865) === 917 917 944 + 918 918 ((( 919 919 (% style="color:blue" %)**Uplink:** 920 920 ))) ... ... @@ -951,19 +951,22 @@ 951 951 952 952 == 2.9 LED Indicator == 953 953 981 + 954 954 The LSPH01 has an internal LED which is to show the status of different state. 955 955 956 956 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. 957 957 * Blink once when device transmit a packet. 958 958 959 -== 2.10 Firmware Change Log == 960 960 961 961 962 -**Firmware download link:** 963 963 964 -[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]] 965 965 991 +== 2.10 Firmware Change Log == 966 966 993 + 994 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]] 995 + 996 + 967 967 **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]] 968 968 969 969 ... ... @@ -970,6 +970,7 @@ 970 970 971 971 = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink = 972 972 1003 + 973 973 ((( 974 974 Use can configure LSPH01 via AT Command or LoRaWAN Downlink. 975 975 ))) ... ... @@ -1001,7 +1001,7 @@ 1001 1001 ))) 1002 1002 1003 1003 ((( 1004 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1035 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1005 1005 ))) 1006 1006 1007 1007 ((( ... ... @@ -1020,6 +1020,7 @@ 1020 1020 1021 1021 == 3.1 Set Transmit Interval Time == 1022 1022 1054 + 1023 1023 Feature: Change LoRaWAN End Node Transmit Interval. 1024 1024 1025 1025 (% style="color:#037691" %)**AT Command: AT+TDC** ... ... @@ -1027,7 +1027,6 @@ 1027 1027 [[image:image-20220607171554-8.png]] 1028 1028 1029 1029 1030 - 1031 1031 ((( 1032 1032 (% style="color:#037691" %)**Downlink Command: 0x01** 1033 1033 ))) ... ... @@ -1047,16 +1047,18 @@ 1047 1047 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1048 1048 1049 1049 1081 + 1050 1050 1051 1051 ))) 1052 1052 1053 1053 == 3.2 Set Interrupt Mode == 1054 1054 1087 + 1055 1055 Feature, Set Interrupt mode for GPIO_EXIT. 1056 1056 1057 1057 (% style="color:#037691" %)**AT Command: AT+INTMOD** 1058 1058 1059 -[[image:image-2022060 7171716-9.png]]1092 +[[image:image-20220610105907-1.png]] 1060 1060 1061 1061 1062 1062 ((( ... ... @@ -1086,6 +1086,7 @@ 1086 1086 1087 1087 == 3.3 Calibrate Sensor == 1088 1088 1122 + 1089 1089 Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands 1090 1090 1091 1091 ... ... @@ -1092,6 +1092,7 @@ 1092 1092 1093 1093 == 3.4 Get Firmware Version Info == 1094 1094 1129 + 1095 1095 Feature: use downlink to get firmware version. 1096 1096 1097 1097 (% style="color:#037691" %)**Downlink Command: 0x26** ... ... @@ -1122,10 +1122,10 @@ 1122 1122 Always 0x02 1123 1123 ))) 1124 1124 1125 -**Software Type**: Always 0x03 for LSPH01 1160 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01 1126 1126 1127 1127 1128 -**Frequency Band**: 1163 +(% style="color:#037691" %)**Frequency Band**: 1129 1129 1130 1130 *0x01: EU868 1131 1131 ... ... @@ -1148,13 +1148,13 @@ 1148 1148 *0xa0: AS923-3 1149 1149 1150 1150 1151 -**Sub-Band**: value 0x00 ~~ 0x08 1186 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08 1152 1152 1153 1153 1154 -**Firmware Version**: 0x0100, Means: v1.0.0 version 1189 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version 1155 1155 1156 1156 1157 -**Sensor Type**: 1192 +(% style="color:#037691" %)**Sensor Type**: 1158 1158 1159 1159 0x01: LSE01 1160 1160 ... ... @@ -1174,14 +1174,18 @@ 1174 1174 1175 1175 = 4. Battery & How to replace = 1176 1176 1212 + 1177 1177 == 4.1 Battery Type == 1178 1178 1215 + 1179 1179 ((( 1180 1180 LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 1181 1181 ))) 1182 1182 1183 1183 ((( 1184 -The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 1221 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 1222 + 1223 + 1185 1185 ))) 1186 1186 1187 1187 [[image:1654593587246-335.png]] ... ... @@ -1195,6 +1195,7 @@ 1195 1195 1196 1196 == 4.2 Replace Battery == 1197 1197 1237 + 1198 1198 ((( 1199 1199 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 1200 1200 ))) ... ... @@ -1207,6 +1207,7 @@ 1207 1207 1208 1208 == 4.3 Power Consumption Analyze == 1209 1209 1250 + 1210 1210 ((( 1211 1211 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 1212 1212 ))) ... ... @@ -1216,12 +1216,12 @@ 1216 1216 ))) 1217 1217 1218 1218 1219 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 1260 +(% style="color:#037691" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 1220 1220 1221 1221 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 1222 1222 1223 1223 1224 -**Step 2**: Open it and choose 1265 +(% style="color:#037691" %)**Step 2**(%%): Open it and choose 1225 1225 1226 1226 * Product Model 1227 1227 * Uplink Interval ... ... @@ -1235,13 +1235,13 @@ 1235 1235 The battery related documents as below: 1236 1236 1237 1237 * ((( 1238 -[[Battery Dimension>> url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],1279 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], 1239 1239 ))) 1240 1240 * ((( 1241 1241 [[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 1242 1242 ))) 1243 1243 * ((( 1244 -[[Lithium-ion Battery-Capacitor datasheet>> url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]1285 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]] 1245 1245 ))) 1246 1246 1247 1247 [[image:image-20220607172042-11.png]] ... ... @@ -1250,6 +1250,7 @@ 1250 1250 1251 1251 === 4.3.1 Battery Note === 1252 1252 1294 + 1253 1253 ((( 1254 1254 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 1255 1255 ))) ... ... @@ -1258,12 +1258,13 @@ 1258 1258 1259 1259 === 4.3.2 Replace the battery === 1260 1260 1303 + 1261 1261 ((( 1262 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won ’t be voltage drop between battery and main board.1305 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 1263 1263 ))) 1264 1264 1265 1265 ((( 1266 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can ’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)1309 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 1267 1267 ))) 1268 1268 1269 1269 ... ... @@ -1270,12 +1270,16 @@ 1270 1270 1271 1271 = 5. Use AT Command = 1272 1272 1316 + 1273 1273 == 5.1 Access AT Commands == 1274 1274 1319 + 1275 1275 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below. 1276 1276 1322 + 1277 1277 [[image:1654593668970-604.png]] 1278 1278 1325 + 1279 1279 **Connection:** 1280 1280 1281 1281 (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** ... ... @@ -1297,21 +1297,28 @@ 1297 1297 1298 1298 = 6. FAQ = 1299 1299 1347 + 1300 1300 == 6.1 How to change the LoRa Frequency Bands/Region == 1301 1301 1350 + 1302 1302 You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]]. 1303 1303 When downloading the images, choose the required image file for download. 1304 1304 1305 1305 1355 + 1306 1306 = 7. Trouble Shooting = 1307 1307 1308 -== 7.1 AT Commands input doesn’t work == 1309 1309 1310 - Inthe case if user can see the console output but can’t type input to the device.Pleasecheck if youalready include the (%style="color:green"%)**ENTER**(%%) while sending outthe command. Someerial tool doesn’tsend (% style="color:green" %)**ENTER**(%%) while press the sendkey,user need to add ENTER in their string.1359 +== 7.1 AT Commands input doesn't work == 1311 1311 1312 1312 1362 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1363 + 1364 + 1365 + 1313 1313 = 8. Order Info = 1314 1314 1368 + 1315 1315 Part Number: (% style="color:blue" %)**LSPH01-XX** 1316 1316 1317 1317 ... ... @@ -1326,6 +1326,9 @@ 1326 1326 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1327 1327 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1328 1328 1383 + 1384 + 1385 + 1329 1329 = 9. Packing Info = 1330 1330 1331 1331 ... ... @@ -1340,9 +1340,15 @@ 1340 1340 * Package Size / pcs : cm 1341 1341 * Weight / pcs : g 1342 1342 1400 + 1401 + 1402 + 1343 1343 = 10. Support = 1344 1344 1405 + 1345 1345 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1346 1346 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]. 1347 1347 1409 + 1410 + 1348 1348
- image-20220610105907-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.5 KB - Content