67 67  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
68 68  
69 69  (((
70 +
71 +
70 70  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
71 71  )))
72 72  
... ... @@ -108,9 +108,6 @@
108 108  * IP68 rate for the Sensor Probe
109 109  * 8500mAh Battery for long term use
110 110  
111 -
112 -
113 -
114 114  == 1.3 Probe Specification ==
115 115  
116 116  
... ... @@ -162,10 +162,14 @@
162 162  
163 163  (((
164 164  [[image:1654592492399-921.png]]
164 +
165 +
165 165  )))
166 166  
167 167  (((
168 168  The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
170 +
171 +
169 169  )))
170 170  
171 171  (((
... ... @@ -189,11 +189,13 @@
189 189  [[image:1654592600093-601.png]]
190 190  
191 191  
195 +
192 192  **Add APP EUI and DEV EUI**
193 193  
194 194  [[image:1654592619856-881.png]]
195 195  
196 196  
201 +
197 197  **Add APP EUI in the application**
198 198  
199 199  [[image:1654592632656-512.png]]
... ... @@ -349,7 +349,7 @@
349 349  
350 350  == 2.4 Uplink Interval ==
351 351  
352 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
357 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
353 353  
354 354  
355 355  
... ... @@ -624,6 +624,8 @@
624 624  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
625 625  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
626 626  
632 +
633 +
627 627  === 2.8.3 CN470-510 (CN470) ===
628 628  
629 629  (((
... ... @@ -1027,7 +1027,6 @@
1027 1027  [[image:image-20220607171554-8.png]]
1028 1028  
1029 1029  
1030 -
1031 1031  (((
1032 1032  (% style="color:#037691" %)**Downlink Command: 0x01**
1033 1033  )))
... ... @@ -1056,7 +1056,7 @@
1056 1056  
1057 1057  (% style="color:#037691" %)**AT Command: AT+INTMOD**
1058 1058  
1059 -[[image:image-20220607171716-9.png]]
1065 +[[image:image-20220610105907-1.png]]
1060 1060  
1061 1061  
1062 1062  (((
... ... @@ -1181,7 +1181,7 @@
1181 1181  )))
1182 1182  
1183 1183  (((
1184 -The discharge curve is not linear so cant simply use percentage to show the battery level. Below is the battery performance.
1190 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1185 1185  )))
1186 1186  
1187 1187  [[image:1654593587246-335.png]]
... ... @@ -1235,13 +1235,13 @@
1235 1235  The battery related documents as below:
1236 1236  
1237 1237  * (((
1238 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1244 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
1239 1239  )))
1240 1240  * (((
1241 1241  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1242 1242  )))
1243 1243  * (((
1244 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1250 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
1245 1245  )))
1246 1246  
1247 1247  [[image:image-20220607172042-11.png]]
... ... @@ -1305,11 +1305,12 @@
1305 1305  
1306 1306  = 7. Trouble Shooting =
1307 1307  
1308 -== 7.1 AT Commands input doesnt work ==
1314 +== 7.1 AT Commands input doesn't work ==
1309 1309  
1310 -In the case if user can see the console output but cant type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1316 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1311 1311  
1312 1312  
1319 +
1313 1313  = 8. Order Info =
1314 1314  
1315 1315  Part Number: (% style="color:blue" %)**LSPH01-XX**
... ... @@ -1326,6 +1326,10 @@
1326 1326  * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1327 1327  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1328 1328  
1336 +
1337 +
1338 +
1339 +
1329 1329  = 9. ​Packing Info =
1330 1330  
1331 1331  
... ... @@ -1340,6 +1340,10 @@
1340 1340  * Package Size / pcs : cm
1341 1341  * Weight / pcs : g
1342 1342  
1354 +
1355 +
1356 +
1357 +
1343 1343  = 10. ​Support =
1344 1344  