From version < 85.11 >
edited by Xiaoling
on 2022/06/08 11:38
To version < 86.5 >
edited by Xiaoling
on 2022/06/14 14:31
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,7 +4,7 @@
4 4  
5 5  
6 6  
7 -**Contents:**
7 +**Table of Contents:**
8 8  
9 9  * [[1. Introduction>>path:#H1.Introduction]]
10 10  ** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
... ... @@ -69,6 +69,8 @@
69 69  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
70 70  
71 71  (((
72 +
73 +
72 72  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
73 73  )))
74 74  
... ... @@ -112,6 +112,7 @@
112 112  
113 113  
114 114  
117 +
115 115  == 1.3 Probe Specification ==
116 116  
117 117  
... ... @@ -124,6 +124,7 @@
124 124  * IP68 Protection
125 125  * Length: 3.5 meters
126 126  
130 +
127 127  (% style="color:#4f81bd" %)**Soil Temperature:**
128 128  
129 129  * Range -40℃~85℃
... ... @@ -134,12 +134,11 @@
134 134  
135 135  
136 136  
141 +
137 137  == 1.4 ​Applications ==
138 138  
139 139  * Smart Agriculture
140 140  
141 -
142 -
143 143  == 1.5 Pin mapping and power on ==
144 144  
145 145  [[image:1654592472094-134.png]]
... ... @@ -335,8 +335,6 @@
335 335  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
336 336  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
337 337  
338 -
339 -
340 340  === 2.3.7 Decode payload in The Things Network ===
341 341  
342 342  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -356,7 +356,7 @@
356 356  
357 357  == 2.4 Uplink Interval ==
358 358  
359 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
360 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
360 360  
361 361  
362 362  
... ... @@ -504,8 +504,6 @@
504 504  
505 505  )))
506 506  
507 -
508 -
509 509  == 2.7 Calibration ==
510 510  
511 511  (((
... ... @@ -522,11 +522,9 @@
522 522  (% style="color:#037691" %)**Calibration Payload**
523 523  
524 524  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
525 -|(((
526 -**Size**
527 -
528 -**(bytes)**
529 -)))|**1**|**1**|**1**|**7**|**1**
524 +|=(% style="width: 62.5px;" %)(((
525 +**Size (bytes)**
526 +)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1**
530 530  |**Value**|(((
531 531  PH4
532 532  
... ... @@ -549,6 +549,7 @@
549 549  * Reply to the confirmation package: 14 01
550 550  * Reply to non-confirmed packet: 14 00
551 551  
549 +
552 552  == 2.8 Frequency Plans ==
553 553  
554 554  (((
... ... @@ -633,6 +633,7 @@
633 633  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
634 634  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
635 635  
634 +
636 636  === 2.8.3 CN470-510 (CN470) ===
637 637  
638 638  (((
... ... @@ -1065,7 +1065,7 @@
1065 1065  
1066 1066  (% style="color:#037691" %)**AT Command: AT+INTMOD**
1067 1067  
1068 -[[image:image-20220607171716-9.png]]
1067 +[[image:image-20220610105907-1.png]]
1069 1069  
1070 1070  
1071 1071  (((
... ... @@ -1319,6 +1319,7 @@
1319 1319  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1320 1320  
1321 1321  
1321 +
1322 1322  = 8. Order Info =
1323 1323  
1324 1324  Part Number: (% style="color:blue" %)**LSPH01-XX**
image-20220610105907-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +15.5 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0