Changes for page LSPH01 -- LoRaWAN Soil pH Sensor User Manual
Last modified by Xiaoling on 2025/04/25 14:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,7 +4,7 @@ 4 4 5 5 6 6 7 -**Contents:** 7 +**Table of Contents:** 8 8 9 9 * [[1. Introduction>>path:#H1.Introduction]] 10 10 ** [[1.1 What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]] ... ... @@ -68,6 +68,8 @@ 68 68 == 1.1 What is LoRaWAN Soil pH Sensor == 69 69 70 70 ((( 71 + 72 + 71 71 The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof. 72 72 ))) 73 73 ... ... @@ -92,6 +92,7 @@ 92 92 93 93 94 94 97 + 95 95 == 1.2 Features == 96 96 97 97 * LoRaWAN 1.0.3 Class A ... ... @@ -147,7 +147,7 @@ 147 147 ))) 148 148 149 149 ((( 150 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >> path:#H5.UseATCommand]]to set the keys in the LSPH01.153 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01. 151 151 ))) 152 152 153 153 ... ... @@ -159,10 +159,14 @@ 159 159 160 160 ((( 161 161 [[image:1654592492399-921.png]] 165 + 166 + 162 162 ))) 163 163 164 164 ((( 165 165 The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. 171 + 172 + 166 166 ))) 167 167 168 168 ((( ... ... @@ -186,11 +186,13 @@ 186 186 [[image:1654592600093-601.png]] 187 187 188 188 196 + 189 189 **Add APP EUI and DEV EUI** 190 190 191 191 [[image:1654592619856-881.png]] 192 192 193 193 202 + 194 194 **Add APP EUI in the application** 195 195 196 196 [[image:1654592632656-512.png]] ... ... @@ -233,19 +233,17 @@ 233 233 ))) 234 234 235 235 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %) 236 -|((( 237 -**Size** 245 +|=(% style="width: 62.5px;" %)((( 246 +**Size (bytes)** 247 +)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1** 248 +|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)((( 249 +[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]] 238 238 239 -**(bytes)** 240 -)))|**2**|**2**|**2**|**2**|**1**|**1**|**1** 241 -|**Value**|[[BAT>>path:#H2.3.1BatteryInfo]]|((( 242 -[[Temperature>>path:#H2.3.2DS18B20Temperaturesensor]] 243 - 244 -[[(Optional)>>path:#H2.3.2DS18B20Temperaturesensor]] 245 -)))|[[Soil pH>>path:#H2.3.3SoilpH]]|[[Soil Temperature>>path:#H2.3.4SoilTemperature]]|((( 246 -[[Digital Interrupt (Optional)>>path:#H2.3.5InterruptPin]] 251 +[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]] 252 +)))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|((( 253 +[[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]] 247 247 )))|Reserve|((( 248 -[[Message Type>> path:#H2.3.6MessageType]]255 +[[Message Type>>||anchor="H2.3.6MessageType"]] 249 249 ))) 250 250 251 251 [[image:1654592721645-318.png]] ... ... @@ -301,7 +301,7 @@ 301 301 302 302 === 2.3.5 Interrupt Pin === 303 303 304 -This data field shows if this packet is generated by interrupt or not. [[Click here>> path:#H3.2SetInterruptMode]] for the hardware and software set up.311 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up. 305 305 306 306 307 307 **Example:** ... ... @@ -323,11 +323,11 @@ 323 323 ))) 324 324 325 325 326 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width: 510px" %)327 -|=**Message Type Code**|=**Description**|=**Payload** 328 -|0x01|Normal Uplink|[[Normal Uplink Payload>> path:#H2.3200BUplinkPayload]]329 -|0x02|Reply configures info|[[Configure Info Payload>> path:#H3.4GetFirmwareVersionInfo]]330 -|0x03|Reply Calibration Info|[[Calibration Payload>> path:#H2.7Calibration]]333 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:499px" %) 334 +|=(% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload** 335 +|(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]] 336 +|(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]] 337 +|(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]] 331 331 332 332 === 2.3.7 Decode payload in The Things Network === 333 333 ... ... @@ -348,7 +348,7 @@ 348 348 349 349 == 2.4 Uplink Interval == 350 350 351 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>> path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]358 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] 352 352 353 353 354 354 ... ... @@ -512,11 +512,9 @@ 512 512 (% style="color:#037691" %)**Calibration Payload** 513 513 514 514 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 515 -|((( 516 -**Size** 517 - 518 -**(bytes)** 519 -)))|**1**|**1**|**1**|**7**|**1** 522 +|=(% style="width: 62.5px;" %)((( 523 +**Size (bytes)** 524 +)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1** 520 520 |**Value**|((( 521 521 PH4 522 522 ... ... @@ -526,7 +526,7 @@ 526 526 527 527 Calibrate value 528 528 )))|Reserve|((( 529 -[[Message Type>> path:#H2.3.6MessageType]]534 +[[Message Type>>||anchor="H2.3.6MessageType"]] 530 530 531 531 Always 0x03 532 532 ))) ... ... @@ -961,9 +961,6 @@ 961 961 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. 962 962 * Blink once when device transmit a packet. 963 963 964 - 965 - 966 - 967 967 == 2.10 Firmware Change Log == 968 968 969 969 ... ... @@ -983,7 +983,7 @@ 983 983 ))) 984 984 985 985 * ((( 986 -AT Command Connection: See [[FAQ>> path:#H6.FAQ]].988 +AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]]. 987 987 ))) 988 988 * ((( 989 989 LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]] ... ... @@ -1035,7 +1035,6 @@ 1035 1035 [[image:image-20220607171554-8.png]] 1036 1036 1037 1037 1038 - 1039 1039 ((( 1040 1040 (% style="color:#037691" %)**Downlink Command: 0x01** 1041 1041 ))) ... ... @@ -1064,7 +1064,7 @@ 1064 1064 1065 1065 (% style="color:#037691" %)**AT Command: AT+INTMOD** 1066 1066 1067 -[[image:image-2022060 7171716-9.png]]1068 +[[image:image-20220610105907-1.png]] 1068 1068 1069 1069 1070 1070 ((( ... ... @@ -1094,7 +1094,7 @@ 1094 1094 1095 1095 == 3.3 Calibrate Sensor == 1096 1096 1097 -Detail See [[Calibration Guide>> path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands1098 +Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands 1098 1098 1099 1099 1100 1100 ... ... @@ -1126,7 +1126,7 @@ 1126 1126 1127 1127 Version 1128 1128 )))|Sensor Type|Reserve|((( 1129 -[[Message Type>> path:#H2.3.6MessageType]]1130 +[[Message Type>>||anchor="H2.3.6MessageType"]] 1130 1130 Always 0x02 1131 1131 ))) 1132 1132 ... ... @@ -1189,7 +1189,7 @@ 1189 1189 ))) 1190 1190 1191 1191 ((( 1192 -The discharge curve is not linear so can ’t simply use percentage to show the battery level. Below is the battery performance.1193 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 1193 1193 ))) 1194 1194 1195 1195 [[image:1654593587246-335.png]] ... ... @@ -1243,13 +1243,13 @@ 1243 1243 The battery related documents as below: 1244 1244 1245 1245 * ((( 1246 -[[Battery Dimension>> url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],1247 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], 1247 1247 ))) 1248 1248 * ((( 1249 1249 [[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 1250 1250 ))) 1251 1251 * ((( 1252 -[[Lithium-ion Battery-Capacitor datasheet>> url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]1253 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]] 1253 1253 ))) 1254 1254 1255 1255 [[image:image-20220607172042-11.png]] ... ... @@ -1300,7 +1300,7 @@ 1300 1300 1301 1301 [[image:1654593712276-618.png]] 1302 1302 1303 -Valid AT Command please check [[Configure Device>> path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]].1304 +Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]]. 1304 1304 1305 1305 1306 1306 = 6. FAQ = ... ... @@ -1307,7 +1307,7 @@ 1307 1307 1308 1308 == 6.1 How to change the LoRa Frequency Bands/Region == 1309 1309 1310 -You can follow the instructions for [[how to upgrade image>> path:#H2.10200BFirmwareChangeLog]].1311 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]]. 1311 1311 When downloading the images, choose the required image file for download. 1312 1312 1313 1313 ... ... @@ -1318,6 +1318,7 @@ 1318 1318 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1319 1319 1320 1320 1322 + 1321 1321 = 8. Order Info = 1322 1322 1323 1323 Part Number: (% style="color:blue" %)**LSPH01-XX** ... ... @@ -1335,6 +1335,10 @@ 1335 1335 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1336 1336 1337 1337 1340 + 1341 + 1342 + 1343 + 1338 1338 = 9. Packing Info = 1339 1339 1340 1340 ... ... @@ -1350,6 +1350,10 @@ 1350 1350 * Weight / pcs : g 1351 1351 1352 1352 1359 + 1360 + 1361 + 1362 + 1353 1353 = 10. Support = 1354 1354 1355 1355 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- image-20220610105907-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.5 KB - Content