Last modified by Xiaoling on 2025/04/25 14:08

From version 79.4
edited by Xiaoling
on 2022/06/07 18:02
Change comment: There is no comment for this version
To version 89.1
edited by Xiaoling
on 2022/06/25 16:45
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,7 +4,7 @@
4 4  
5 5  
6 6  
7 -**Contents:**
7 +**Table of Contents:**
8 8  
9 9  * [[1. Introduction>>path:#H1.Introduction]]
10 10  ** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
... ... @@ -62,11 +62,15 @@
62 62  * [[10. ​Support>>path:#H10.A0200BSupport]]
63 63  
64 64  
65 +
66 +
65 65  = 1. Introduction =
66 66  
67 67  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
68 68  
69 69  (((
72 +
73 +
70 70  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
71 71  )))
72 72  
... ... @@ -91,6 +91,7 @@
91 91  
92 92  
93 93  
98 +
94 94  == ​1.2 Features ==
95 95  
96 96  * LoRaWAN 1.0.3 Class A
... ... @@ -146,7 +146,7 @@
146 146  )))
147 147  
148 148  (((
149 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>path:#H5.UseATCommand]]to set the keys in the LSPH01.
154 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
150 150  )))
151 151  
152 152  
... ... @@ -158,10 +158,14 @@
158 158  
159 159  (((
160 160  [[image:1654592492399-921.png]]
166 +
167 +
161 161  )))
162 162  
163 163  (((
164 164  The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
172 +
173 +
165 165  )))
166 166  
167 167  (((
... ... @@ -185,11 +185,13 @@
185 185  [[image:1654592600093-601.png]]
186 186  
187 187  
197 +
188 188  **Add APP EUI and DEV EUI**
189 189  
190 190  [[image:1654592619856-881.png]]
191 191  
192 192  
203 +
193 193  **Add APP EUI in the application**
194 194  
195 195  [[image:1654592632656-512.png]]
... ... @@ -232,19 +232,17 @@
232 232  )))
233 233  
234 234  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
235 -|(((
236 -**Size**
246 +|=(% style="width: 62.5px;" %)(((
247 +**Size (bytes)**
248 +)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1**
249 +|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)(((
250 +[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
237 237  
238 -**(bytes)**
239 -)))|**2**|**2**|**2**|**2**|**1**|**1**|**1**
240 -|**Value**|[[BAT>>path:#H2.3.1BatteryInfo]]|(((
241 -[[Temperature>>path:#H2.3.2DS18B20Temperaturesensor]]
242 -
243 -[[(Optional)>>path:#H2.3.2DS18B20Temperaturesensor]]
244 -)))|[[Soil pH>>path:#H2.3.3SoilpH]]|[[Soil Temperature>>path:#H2.3.4SoilTemperature]]|(((
245 -[[Digital Interrupt (Optional)>>path:#H2.3.5InterruptPin]]
252 +[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
253 +)))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
254 +[[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
246 246  )))|Reserve|(((
247 -[[Message Type>>path:#H2.3.6MessageType]]
256 +[[Message Type>>||anchor="H2.3.6MessageType"]]
248 248  )))
249 249  
250 250  [[image:1654592721645-318.png]]
... ... @@ -300,7 +300,7 @@
300 300  
301 301  === 2.3.5 Interrupt Pin ===
302 302  
303 -This data field shows if this packet is generated by interrupt or not. [[Click here>>path:#H3.2SetInterruptMode]] for the hardware and software set up.
312 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
304 304  
305 305  
306 306  **Example:**
... ... @@ -322,11 +322,11 @@
322 322  )))
323 323  
324 324  
325 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
326 -|=**Message Type Code**|=**Description**|=**Payload**
327 -|0x01|Normal Uplink|[[Normal Uplink Payload>>path:#H2.3200BUplinkPayload]]
328 -|0x02|Reply configures info|[[Configure Info Payload>>path:#H3.4GetFirmwareVersionInfo]]
329 -|0x03|Reply Calibration Info|[[Calibration Payload>>path:#H2.7Calibration]]
334 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:499px" %)
335 +|=(% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload**
336 +|(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
337 +|(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
338 +|(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
330 330  
331 331  === 2.3.7 Decode payload in The Things Network ===
332 332  
... ... @@ -347,7 +347,7 @@
347 347  
348 348  == 2.4 Uplink Interval ==
349 349  
350 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
359 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
351 351  
352 352  
353 353  
... ... @@ -511,11 +511,9 @@
511 511  (% style="color:#037691" %)**Calibration Payload**
512 512  
513 513  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
514 -|(((
515 -**Size**
516 -
517 -**(bytes)**
518 -)))|**1**|**1**|**1**|**7**|**1**
523 +|=(% style="width: 62.5px;" %)(((
524 +**Size (bytes)**
525 +)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1**
519 519  |**Value**|(((
520 520  PH4
521 521  
... ... @@ -525,7 +525,7 @@
525 525  
526 526  Calibrate value
527 527  )))|Reserve|(((
528 -[[Message Type>>path:#H2.3.6MessageType]]
535 +[[Message Type>>||anchor="H2.3.6MessageType"]]
529 529  
530 530  Always 0x03
531 531  )))
... ... @@ -541,6 +541,7 @@
541 541  
542 542  
543 543  
551 +
544 544  == 2.8 Frequency Plans ==
545 545  
546 546  (((
... ... @@ -628,6 +628,7 @@
628 628  
629 629  
630 630  
639 +
631 631  === 2.8.3 CN470-510 (CN470) ===
632 632  
633 633  (((
... ... @@ -737,9 +737,6 @@
737 737  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
738 738  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
739 739  
740 -
741 -
742 -
743 743  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
744 744  
745 745  (((
... ... @@ -963,8 +963,6 @@
963 963  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
964 964  * Blink once when device transmit a packet.
965 965  
966 -
967 -
968 968  == 2.10 ​Firmware Change Log ==
969 969  
970 970  
... ... @@ -984,7 +984,7 @@
984 984  )))
985 985  
986 986  * (((
987 -AT Command Connection: See [[FAQ>>path:#H6.FAQ]].
991 +AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
988 988  )))
989 989  * (((
990 990  LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
... ... @@ -1036,7 +1036,6 @@
1036 1036  [[image:image-20220607171554-8.png]]
1037 1037  
1038 1038  
1039 -
1040 1040  (((
1041 1041  (% style="color:#037691" %)**Downlink Command: 0x01**
1042 1042  )))
... ... @@ -1065,7 +1065,7 @@
1065 1065  
1066 1066  (% style="color:#037691" %)**AT Command: AT+INTMOD**
1067 1067  
1068 -[[image:image-20220607171716-9.png]]
1071 +[[image:image-20220610105907-1.png]]
1069 1069  
1070 1070  
1071 1071  (((
... ... @@ -1095,7 +1095,7 @@
1095 1095  
1096 1096  == 3.3 Calibrate Sensor ==
1097 1097  
1098 -Detail See [[Calibration Guide>>path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands
1101 +Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
1099 1099  
1100 1100  
1101 1101  
... ... @@ -1127,7 +1127,7 @@
1127 1127  
1128 1128  Version
1129 1129  )))|Sensor Type|Reserve|(((
1130 -[[Message Type>>path:#H2.3.6MessageType]]
1133 +[[Message Type>>||anchor="H2.3.6MessageType"]]
1131 1131  Always 0x02
1132 1132  )))
1133 1133  
... ... @@ -1190,7 +1190,7 @@
1190 1190  )))
1191 1191  
1192 1192  (((
1193 -The discharge curve is not linear so cant simply use percentage to show the battery level. Below is the battery performance.
1196 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1194 1194  )))
1195 1195  
1196 1196  [[image:1654593587246-335.png]]
... ... @@ -1244,13 +1244,13 @@
1244 1244  The battery related documents as below:
1245 1245  
1246 1246  * (((
1247 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1250 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
1248 1248  )))
1249 1249  * (((
1250 1250  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1251 1251  )))
1252 1252  * (((
1253 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1256 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
1254 1254  )))
1255 1255  
1256 1256  [[image:image-20220607172042-11.png]]
... ... @@ -1301,19 +1301,17 @@
1301 1301  
1302 1302   [[image:1654593712276-618.png]]
1303 1303  
1304 -Valid AT Command please check [[Configure Device>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]].
1307 +Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]].
1305 1305  
1306 1306  
1307 -
1308 1308  = 6. FAQ =
1309 1309  
1310 1310  == 6.1 How to change the LoRa Frequency Bands/Region ==
1311 1311  
1312 -You can follow the instructions for [[how to upgrade image>>path:#H2.10200BFirmwareChangeLog]].
1314 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1313 1313  When downloading the images, choose the required image file for download. ​
1314 1314  
1315 1315  
1316 -
1317 1317  = 7. Trouble Shooting =
1318 1318  
1319 1319  == 7.1 AT Commands input doesn’t work ==
image-20220610105907-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +15.5 KB
Content