Last modified by Xiaoling on 2025/04/25 14:08

From version 79.1
edited by Xiaoling
on 2022/06/07 18:01
Change comment: There is no comment for this version
To version 98.11
edited by Xiaoling
on 2022/08/18 16:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,70 +4,36 @@
4 4  
5 5  
6 6  
7 -**Contents:**
8 8  
9 -* [[1. Introduction>>path:#H1.Introduction]]
10 -** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 -** [[​1.2 Features>>path:#H200B1.2Features]]
12 -** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 -** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 -** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 -* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 -** [[2.1 How it works>>path:#H2.1Howitworks]]
17 -** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 -** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 -*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 -*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 -*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 -*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 -*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 -*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 -*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 -** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 -** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 -** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 -*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 -*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 -*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 -** [[2.7 Calibration>>path:#H2.7Calibration]]
33 -** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 -*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 -*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 -*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 -*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 -*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 -*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 -*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 -** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 -** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 -* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 -** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 -** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 -** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 -** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 -* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 -** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 -** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 -** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 -*** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 -*** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 -* [[5. Use AT Command>>path:#H5.UseATCommand]]
55 -** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 -* [[6. FAQ>>path:#H6.FAQ]]
57 -** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 -* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 -** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 -* [[8. Order Info>>path:#H8.OrderInfo]]
61 -* [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 -* [[10. ​Support>>path:#H10.A0200BSupport]]
63 63  
64 64  
65 65  
11 +
12 +
13 +
14 +
15 +
16 +**Table of Contents:**
17 +
18 +{{toc/}}
19 +
20 +
21 +
22 +
23 +
24 +
25 +
26 +
27 +
28 +
66 66  = 1. Introduction =
67 67  
31 +
68 68  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
69 69  
70 70  (((
35 +
36 +
71 71  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
72 72  )))
73 73  
... ... @@ -92,8 +92,10 @@
92 92  
93 93  
94 94  
61 +
95 95  == ​1.2 Features ==
96 96  
64 +
97 97  * LoRaWAN 1.0.3 Class A
98 98  * Ultra-low power consumption
99 99  * Monitor soil pH with temperature compensation.
... ... @@ -108,6 +108,10 @@
108 108  * IP68 rate for the Sensor Probe
109 109  * 8500mAh Battery for long term use
110 110  
79 +
80 +
81 +
82 +
111 111  == 1.3 Probe Specification ==
112 112  
113 113  
... ... @@ -128,12 +128,21 @@
128 128  * IP68 Protection
129 129  * Length: 3.5 meters
130 130  
103 +
104 +
105 +
106 +
131 131  == 1.4 ​Applications ==
132 132  
109 +
133 133  * Smart Agriculture
134 134  
112 +
113 +
114 +
135 135  == 1.5 Pin mapping and power on ==
136 136  
117 +
137 137  [[image:1654592472094-134.png]]
138 138  
139 139  
... ... @@ -140,19 +140,23 @@
140 140  
141 141  = 2. Configure LSPH01 to connect to LoRaWAN network =
142 142  
124 +
143 143  == 2.1 How it works ==
144 144  
127 +
145 145  (((
146 146  The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
147 147  )))
148 148  
149 149  (((
150 -In case you cant set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>path:#H5.UseATCommand]]to set the keys in the LSPH01.
133 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
151 151  )))
152 152  
153 153  
137 +
154 154  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
155 155  
140 +
156 156  (((
157 157  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
158 158  )))
... ... @@ -159,10 +159,14 @@
159 159  
160 160  (((
161 161  [[image:1654592492399-921.png]]
147 +
148 +
162 162  )))
163 163  
164 164  (((
165 165  The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
153 +
154 +
166 166  )))
167 167  
168 168  (((
... ... @@ -186,11 +186,13 @@
186 186  [[image:1654592600093-601.png]]
187 187  
188 188  
178 +
189 189  **Add APP EUI and DEV EUI**
190 190  
191 191  [[image:1654592619856-881.png]]
192 192  
193 193  
184 +
194 194  **Add APP EUI in the application**
195 195  
196 196  [[image:1654592632656-512.png]]
... ... @@ -212,6 +212,8 @@
212 212  
213 213  (((
214 214  (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
206 +
207 +
215 215  )))
216 216  
217 217  [[image:1654592697690-910.png]]
... ... @@ -220,6 +220,7 @@
220 220  
221 221  == 2.3 ​Uplink Payload ==
222 222  
216 +
223 223  (((
224 224  LSPH01 will uplink payload via LoRaWAN with below payload format: 
225 225  )))
... ... @@ -233,19 +233,17 @@
233 233  )))
234 234  
235 235  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
236 -|(((
237 -**Size**
230 +|=(% style="width: 62.5px;" %)(((
231 +**Size (bytes)**
232 +)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1**
233 +|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)(((
234 +[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
238 238  
239 -**(bytes)**
240 -)))|**2**|**2**|**2**|**2**|**1**|**1**|**1**
241 -|**Value**|[[BAT>>path:#H2.3.1BatteryInfo]]|(((
242 -[[Temperature>>path:#H2.3.2DS18B20Temperaturesensor]]
243 -
244 -[[(Optional)>>path:#H2.3.2DS18B20Temperaturesensor]]
245 -)))|[[Soil pH>>path:#H2.3.3SoilpH]]|[[Soil Temperature>>path:#H2.3.4SoilTemperature]]|(((
246 -[[Digital Interrupt (Optional)>>path:#H2.3.5InterruptPin]]
236 +[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
237 +)))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
238 +[[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
247 247  )))|Reserve|(((
248 -[[Message Type>>path:#H2.3.6MessageType]]
240 +[[Message Type>>||anchor="H2.3.6MessageType"]]
249 249  )))
250 250  
251 251  [[image:1654592721645-318.png]]
... ... @@ -265,6 +265,7 @@
265 265  
266 266  === 2.3.2 DS18B20 Temperature sensor ===
267 267  
260 +
268 268  This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
269 269  
270 270  
... ... @@ -278,6 +278,7 @@
278 278  
279 279  === 2.3.3 Soil pH ===
280 280  
274 +
281 281  Range: 0 ~~ 14 pH
282 282  
283 283  **Example:**
... ... @@ -288,6 +288,7 @@
288 288  
289 289  === 2.3.4 Soil Temperature ===
290 290  
285 +
291 291  Get Soil Temperature 
292 292  
293 293  
... ... @@ -301,9 +301,10 @@
301 301  
302 302  === 2.3.5 Interrupt Pin ===
303 303  
304 -This data field shows if this packet is generated by interrupt or not. [[Click here>>path:#H3.2SetInterruptMode]] for the hardware and software set up.
305 305  
300 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
306 306  
302 +
307 307  **Example:**
308 308  
309 309  0x00: Normal uplink packet.
... ... @@ -314,6 +314,7 @@
314 314  
315 315  === 2.3.6 Message Type ===
316 316  
313 +
317 317  (((
318 318  For a normal uplink payload, the message type is always 0x01.
319 319  )))
... ... @@ -323,12 +323,16 @@
323 323  )))
324 324  
325 325  
326 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
327 -|=**Message Type Code**|=**Description**|=**Payload**
328 -|0x01|Normal Uplink|[[Normal Uplink Payload>>path:#H2.3200BUplinkPayload]]
329 -|0x02|Reply configures info|[[Configure Info Payload>>path:#H3.4GetFirmwareVersionInfo]]
330 -|0x03|Reply Calibration Info|[[Calibration Payload>>path:#H2.7Calibration]]
323 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:499px" %)
324 +|=(% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload**
325 +|(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
326 +|(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
327 +|(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
331 331  
329 +
330 +
331 +
332 +
332 332  === 2.3.7 Decode payload in The Things Network ===
333 333  
334 334  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -341,7 +341,7 @@
341 341  )))
342 342  
343 343  (((
344 -LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
345 +LSPH01 TTN Payload Decoder:  [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
345 345  )))
346 346  
347 347  
... ... @@ -348,12 +348,14 @@
348 348  
349 349  == 2.4 Uplink Interval ==
350 350  
351 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
352 352  
353 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
353 353  
354 354  
356 +
355 355  == 2.5 ​Show Data in DataCake IoT Server ==
356 356  
359 +
357 357  (((
358 358  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
359 359  )))
... ... @@ -396,7 +396,7 @@
396 396  )))
397 397  
398 398  (((
399 -Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
402 +Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
400 400  )))
401 401  
402 402  
... ... @@ -417,8 +417,10 @@
417 417  
418 418  == 2.6 Installation and Maintain ==
419 419  
423 +
420 420  === 2.6.1 Before measurement ===
421 421  
426 +
422 422  (((
423 423  (((
424 424  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
... ... @@ -436,6 +436,8 @@
436 436  
437 437  (((
438 438  [[image:1654592946732-634.png]]
444 +
445 +
439 439  )))
440 440  
441 441  (((
... ... @@ -447,7 +447,7 @@
447 447  )))
448 448  
449 449  (((
450 -Slowly insert the probe to the measure point. Dont use large force which will break the probe. Make sure not shake when inserting.
457 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting.
451 451  )))
452 452  
453 453  (((
... ... @@ -474,6 +474,7 @@
474 474  
475 475  === 2.6.3 Maintain Probe ===
476 476  
484 +
477 477  1. (((
478 478  pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
479 479  )))
... ... @@ -498,6 +498,7 @@
498 498  
499 499  == 2.7 Calibration ==
500 500  
509 +
501 501  (((
502 502  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
503 503  )))
... ... @@ -512,11 +512,9 @@
512 512  (% style="color:#037691" %)**Calibration Payload**
513 513  
514 514  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
515 -|(((
516 -**Size**
517 -
518 -**(bytes)**
519 -)))|**1**|**1**|**1**|**7**|**1**
524 +|=(% style="width: 62.5px;" %)(((
525 +**Size (bytes)**
526 +)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1**
520 520  |**Value**|(((
521 521  PH4
522 522  
... ... @@ -526,11 +526,12 @@
526 526  
527 527  Calibrate value
528 528  )))|Reserve|(((
529 -[[Message Type>>path:#H2.3.6MessageType]]
536 +[[Message Type>>||anchor="H2.3.6MessageType"]]
530 530  
531 531  Always 0x03
532 532  )))
533 533  
541 +
534 534  User can also send 0x14 downlink command to poll the current calibration payload.
535 535  
536 536  [[image:image-20220607171416-7.jpeg]]
... ... @@ -539,15 +539,21 @@
539 539  * Reply to the confirmation package: 14 01
540 540  * Reply to non-confirmed packet: 14 00
541 541  
550 +
551 +
552 +
542 542  == 2.8 Frequency Plans ==
543 543  
555 +
544 544  (((
545 545  The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
546 546  )))
547 547  
548 548  
561 +
549 549  === 2.8.1 EU863-870 (EU868) ===
550 550  
564 +
551 551  (((
552 552  (% style="color:blue" %)**Uplink:**
553 553  )))
... ... @@ -608,6 +608,7 @@
608 608  
609 609  === 2.8.2 US902-928(US915) ===
610 610  
625 +
611 611  (((
612 612  Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
613 613  )))
... ... @@ -621,10 +621,15 @@
621 621  )))
622 622  
623 623  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
624 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
639 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
625 625  
641 +
642 +
643 +
644 +
626 626  === 2.8.3 CN470-510 (CN470) ===
627 627  
647 +
628 628  (((
629 629  Used in China, Default use CHE=1
630 630  )))
... ... @@ -713,6 +713,7 @@
713 713  
714 714  === 2.8.4 AU915-928(AU915) ===
715 715  
736 +
716 716  (((
717 717  Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
718 718  )))
... ... @@ -730,10 +730,15 @@
730 730  )))
731 731  
732 732  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
733 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
754 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
734 734  
756 +
757 +
758 +
759 +
735 735  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
736 736  
762 +
737 737  (((
738 738  (% style="color:blue" %)**Default Uplink channel:**
739 739  )))
... ... @@ -842,6 +842,7 @@
842 842  
843 843  === 2.8.6 KR920-923 (KR920) ===
844 844  
871 +
845 845  (((
846 846  (% style="color:blue" %)**Default channel:**
847 847  )))
... ... @@ -914,6 +914,7 @@
914 914  
915 915  === 2.8.7 IN865-867 (IN865) ===
916 916  
944 +
917 917  (((
918 918  (% style="color:blue" %)**Uplink:**
919 919  )))
... ... @@ -950,6 +950,7 @@
950 950  
951 951  == 2.9 LED Indicator ==
952 952  
981 +
953 953  The LSPH01 has an internal LED which is to show the status of different state.
954 954  
955 955  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
... ... @@ -958,14 +958,13 @@
958 958  
959 959  
960 960  
990 +
961 961  == 2.10 ​Firmware Change Log ==
962 962  
963 963  
964 -**Firmware download link:**
994 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]]
965 965  
966 -[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
967 967  
968 -
969 969  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
970 970  
971 971  
... ... @@ -972,12 +972,13 @@
972 972  
973 973  = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
974 974  
1003 +
975 975  (((
976 976  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
977 977  )))
978 978  
979 979  * (((
980 -AT Command Connection: See [[FAQ>>path:#H6.FAQ]].
1009 +AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
981 981  )))
982 982  * (((
983 983  LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
... ... @@ -1003,7 +1003,7 @@
1003 1003  )))
1004 1004  
1005 1005  (((
1006 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1035 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1007 1007  )))
1008 1008  
1009 1009  (((
... ... @@ -1022,6 +1022,7 @@
1022 1022  
1023 1023  == 3.1 Set Transmit Interval Time ==
1024 1024  
1054 +
1025 1025  Feature: Change LoRaWAN End Node Transmit Interval.
1026 1026  
1027 1027  (% style="color:#037691" %)**AT Command: AT+TDC**
... ... @@ -1029,7 +1029,6 @@
1029 1029  [[image:image-20220607171554-8.png]]
1030 1030  
1031 1031  
1032 -
1033 1033  (((
1034 1034  (% style="color:#037691" %)**Downlink Command: 0x01**
1035 1035  )))
... ... @@ -1049,16 +1049,18 @@
1049 1049  Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1050 1050  
1051 1051  
1081 +
1052 1052  
1053 1053  )))
1054 1054  
1055 1055  == 3.2 Set Interrupt Mode ==
1056 1056  
1087 +
1057 1057  Feature, Set Interrupt mode for GPIO_EXIT.
1058 1058  
1059 1059  (% style="color:#037691" %)**AT Command: AT+INTMOD**
1060 1060  
1061 -[[image:image-20220607171716-9.png]]
1092 +[[image:image-20220610105907-1.png]]
1062 1062  
1063 1063  
1064 1064  (((
... ... @@ -1088,12 +1088,14 @@
1088 1088  
1089 1089  == 3.3 Calibrate Sensor ==
1090 1090  
1091 -Detail See [[Calibration Guide>>path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands
1092 1092  
1123 +Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
1093 1093  
1094 1094  
1126 +
1095 1095  == 3.4 Get Firmware Version Info ==
1096 1096  
1129 +
1097 1097  Feature: use downlink to get firmware version.
1098 1098  
1099 1099  (% style="color:#037691" %)**Downlink Command: 0x26**
... ... @@ -1120,14 +1120,14 @@
1120 1120  
1121 1121  Version
1122 1122  )))|Sensor Type|Reserve|(((
1123 -[[Message Type>>path:#H2.3.6MessageType]]
1156 +[[Message Type>>||anchor="H2.3.6MessageType"]]
1124 1124  Always 0x02
1125 1125  )))
1126 1126  
1127 -**Software Type**: Always 0x03 for LSPH01
1160 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01
1128 1128  
1129 1129  
1130 -**Frequency Band**:
1163 +(% style="color:#037691" %)**Frequency Band**:
1131 1131  
1132 1132  *0x01: EU868
1133 1133  
... ... @@ -1150,13 +1150,13 @@
1150 1150  *0xa0: AS923-3
1151 1151  
1152 1152  
1153 -**Sub-Band**: value 0x00 ~~ 0x08
1186 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08
1154 1154  
1155 1155  
1156 -**Firmware Version**: 0x0100, Means: v1.0.0 version
1189 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
1157 1157  
1158 1158  
1159 -**Sensor Type**:
1192 +(% style="color:#037691" %)**Sensor Type**:
1160 1160  
1161 1161  0x01: LSE01
1162 1162  
... ... @@ -1176,14 +1176,18 @@
1176 1176  
1177 1177  = 4. Battery & How to replace =
1178 1178  
1212 +
1179 1179  == 4.1 Battery Type ==
1180 1180  
1215 +
1181 1181  (((
1182 1182  LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1183 1183  )))
1184 1184  
1185 1185  (((
1186 -The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
1221 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1222 +
1223 +
1187 1187  )))
1188 1188  
1189 1189  [[image:1654593587246-335.png]]
... ... @@ -1197,6 +1197,7 @@
1197 1197  
1198 1198  == 4.2 Replace Battery ==
1199 1199  
1237 +
1200 1200  (((
1201 1201  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
1202 1202  )))
... ... @@ -1209,6 +1209,7 @@
1209 1209  
1210 1210  == 4.3 Power Consumption Analyze ==
1211 1211  
1250 +
1212 1212  (((
1213 1213  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
1214 1214  )))
... ... @@ -1218,12 +1218,12 @@
1218 1218  )))
1219 1219  
1220 1220  
1221 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1260 +(% style="color:#037691" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1222 1222  
1223 1223  [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1224 1224  
1225 1225  
1226 -**Step 2**: Open it and choose
1265 +(% style="color:#037691" %)**Step 2**(%%): Open it and choose
1227 1227  
1228 1228  * Product Model
1229 1229  * Uplink Interval
... ... @@ -1237,13 +1237,13 @@
1237 1237  The battery related documents as below:
1238 1238  
1239 1239  * (((
1240 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1279 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
1241 1241  )))
1242 1242  * (((
1243 1243  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1244 1244  )))
1245 1245  * (((
1246 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1285 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
1247 1247  )))
1248 1248  
1249 1249  [[image:image-20220607172042-11.png]]
... ... @@ -1252,6 +1252,7 @@
1252 1252  
1253 1253  === 4.3.1 ​Battery Note ===
1254 1254  
1294 +
1255 1255  (((
1256 1256  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
1257 1257  )))
... ... @@ -1260,12 +1260,13 @@
1260 1260  
1261 1261  === ​4.3.2 Replace the battery ===
1262 1262  
1303 +
1263 1263  (((
1264 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there wont be voltage drop between battery and main board.
1305 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
1265 1265  )))
1266 1266  
1267 1267  (((
1268 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user cant find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1309 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1269 1269  )))
1270 1270  
1271 1271  
... ... @@ -1272,12 +1272,16 @@
1272 1272  
1273 1273  = 5. Use AT Command =
1274 1274  
1316 +
1275 1275  == 5.1 Access AT Commands ==
1276 1276  
1319 +
1277 1277  LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
1278 1278  
1322 +
1279 1279  [[image:1654593668970-604.png]]
1280 1280  
1325 +
1281 1281  **Connection:**
1282 1282  
1283 1283  (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
... ... @@ -1294,15 +1294,16 @@
1294 1294  
1295 1295   [[image:1654593712276-618.png]]
1296 1296  
1297 -Valid AT Command please check [[Configure Device>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]].
1342 +Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]].
1298 1298  
1299 1299  
1300 -
1301 1301  = 6. FAQ =
1302 1302  
1347 +
1303 1303  == 6.1 How to change the LoRa Frequency Bands/Region ==
1304 1304  
1305 -You can follow the instructions for [[how to upgrade image>>path:#H2.10200BFirmwareChangeLog]].
1350 +
1351 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1306 1306  When downloading the images, choose the required image file for download. ​
1307 1307  
1308 1308  
... ... @@ -1309,14 +1309,17 @@
1309 1309  
1310 1310  = 7. Trouble Shooting =
1311 1311  
1312 -== 7.1 AT Commands input doesn’t work ==
1313 1313  
1314 -In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1359 +== 7.1 AT Commands input doesn't work ==
1315 1315  
1316 1316  
1362 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1317 1317  
1364 +
1365 +
1318 1318  = 8. Order Info =
1319 1319  
1368 +
1320 1320  Part Number: (% style="color:blue" %)**LSPH01-XX**
1321 1321  
1322 1322  
... ... @@ -1331,6 +1331,9 @@
1331 1331  * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1332 1332  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1333 1333  
1383 +
1384 +
1385 +
1334 1334  = 9. ​Packing Info =
1335 1335  
1336 1336  
... ... @@ -1345,9 +1345,15 @@
1345 1345  * Package Size / pcs : cm
1346 1346  * Weight / pcs : g
1347 1347  
1400 +
1401 +
1402 +
1348 1348  = 10. ​Support =
1349 1349  
1405 +
1350 1350  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1351 1351  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
1352 1352  
1409 +
1410 +
1353 1353  
image-20220610105907-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +15.5 KB
Content