Last modified by Xiaoling on 2025/04/25 14:08

From version 75.3
edited by Xiaoling
on 2022/06/07 17:59
Change comment: There is no comment for this version
To version 98.13
edited by Xiaoling
on 2022/10/27 13:43
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,72 +4,22 @@
4 4  
5 5  
6 6  
7 -**Contents:**
8 8  
9 -* [[1. Introduction>>path:#H1.Introduction]]
10 -** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 -** [[​1.2 Features>>path:#H200B1.2Features]]
12 -** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 -** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 -** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 -* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 -** [[2.1 How it works>>path:#H2.1Howitworks]]
17 -** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 -** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 -*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 -*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 -*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 -*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 -*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 -*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 -*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 -** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 -** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 -** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 -*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 -*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 -*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 -** [[2.7 Calibration>>path:#H2.7Calibration]]
33 -** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 -*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 -*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 -*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 -*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 -*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 -*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 -*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 -** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 -** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 -* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 -** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 -** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 -** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 -** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 -* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 -** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 -** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 -** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 -*** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 -*** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 -* [[5. Use AT Command>>path:#H5.UseATCommand]]
55 -** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 -* [[6. FAQ>>path:#H6.FAQ]]
57 -** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 -* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 -** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 -* [[8. Order Info>>path:#H8.OrderInfo]]
61 -* [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 -* [[10. ​Support>>path:#H10.A0200BSupport]]
8 +**Table of Contents:**
63 63  
10 +{{toc/}}
64 64  
65 65  
66 66  
67 67  
68 68  
16 +
69 69  = 1. Introduction =
70 70  
19 +
71 71  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
72 72  
22 +
73 73  (((
74 74  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
75 75  )))
... ... @@ -97,6 +97,7 @@
97 97  
98 98  == ​1.2 Features ==
99 99  
50 +
100 100  * LoRaWAN 1.0.3 Class A
101 101  * Ultra-low power consumption
102 102  * Monitor soil pH with temperature compensation.
... ... @@ -111,6 +111,8 @@
111 111  * IP68 rate for the Sensor Probe
112 112  * 8500mAh Battery for long term use
113 113  
65 +
66 +
114 114  == 1.3 Probe Specification ==
115 115  
116 116  
... ... @@ -131,12 +131,17 @@
131 131  * IP68 Protection
132 132  * Length: 3.5 meters
133 133  
87 +
88 +
134 134  == 1.4 ​Applications ==
135 135  
91 +
136 136  * Smart Agriculture
137 137  
94 +
138 138  == 1.5 Pin mapping and power on ==
139 139  
97 +
140 140  [[image:1654592472094-134.png]]
141 141  
142 142  
... ... @@ -143,19 +143,23 @@
143 143  
144 144  = 2. Configure LSPH01 to connect to LoRaWAN network =
145 145  
104 +
146 146  == 2.1 How it works ==
147 147  
107 +
148 148  (((
149 149  The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
150 150  )))
151 151  
152 152  (((
153 -In case you cant set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>path:#H5.UseATCommand]]to set the keys in the LSPH01.
113 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
154 154  )))
155 155  
156 156  
117 +
157 157  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
158 158  
120 +
159 159  (((
160 160  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
161 161  )))
... ... @@ -162,10 +162,14 @@
162 162  
163 163  (((
164 164  [[image:1654592492399-921.png]]
127 +
128 +
165 165  )))
166 166  
167 167  (((
168 168  The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
133 +
134 +
169 169  )))
170 170  
171 171  (((
... ... @@ -189,11 +189,13 @@
189 189  [[image:1654592600093-601.png]]
190 190  
191 191  
158 +
192 192  **Add APP EUI and DEV EUI**
193 193  
194 194  [[image:1654592619856-881.png]]
195 195  
196 196  
164 +
197 197  **Add APP EUI in the application**
198 198  
199 199  [[image:1654592632656-512.png]]
... ... @@ -215,6 +215,8 @@
215 215  
216 216  (((
217 217  (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
186 +
187 +
218 218  )))
219 219  
220 220  [[image:1654592697690-910.png]]
... ... @@ -223,6 +223,7 @@
223 223  
224 224  == 2.3 ​Uplink Payload ==
225 225  
196 +
226 226  (((
227 227  LSPH01 will uplink payload via LoRaWAN with below payload format: 
228 228  )))
... ... @@ -235,20 +235,15 @@
235 235  Normal uplink payload:
236 236  )))
237 237  
238 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
239 -|(((
240 -**Size**
241 -
242 -**(bytes)**
243 -)))|**2**|**2**|**2**|**2**|**1**|**1**|**1**
244 -|**Value**|[[BAT>>path:#H2.3.1BatteryInfo]]|(((
245 -[[Temperature>>path:#H2.3.2DS18B20Temperaturesensor]]
246 -
247 -[[(Optional)>>path:#H2.3.2DS18B20Temperaturesensor]]
248 -)))|[[Soil pH>>path:#H2.3.3SoilpH]]|[[Soil Temperature>>path:#H2.3.4SoilTemperature]]|(((
249 -[[Digital Interrupt (Optional)>>path:#H2.3.5InterruptPin]]
209 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:510px" %)
210 +|=(% style="width: 60px;" %)(((
211 +**Size (bytes)**)))|=(% style="width: 30px;" %)**2**|=(% style="width: 70px;" %)**2**|=(% style="width: 70px;" %)**2**|=(% style="width: 60px;" %)**2**|=(% style="width: 70px;" %)**1**|=(% style="width: 50px;" %)**1**|=(% style="width: 80px;" %)**1**
212 +|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)(((
213 +[[Temperature (Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
214 +)))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
215 +[[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
250 250  )))|Reserve|(((
251 -[[Message Type>>path:#H2.3.6MessageType]]
217 +[[Message Type>>||anchor="H2.3.6MessageType"]]
252 252  )))
253 253  
254 254  [[image:1654592721645-318.png]]
... ... @@ -268,6 +268,7 @@
268 268  
269 269  === 2.3.2 DS18B20 Temperature sensor ===
270 270  
237 +
271 271  This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
272 272  
273 273  
... ... @@ -281,6 +281,7 @@
281 281  
282 282  === 2.3.3 Soil pH ===
283 283  
251 +
284 284  Range: 0 ~~ 14 pH
285 285  
286 286  **Example:**
... ... @@ -291,6 +291,7 @@
291 291  
292 292  === 2.3.4 Soil Temperature ===
293 293  
262 +
294 294  Get Soil Temperature 
295 295  
296 296  
... ... @@ -304,9 +304,10 @@
304 304  
305 305  === 2.3.5 Interrupt Pin ===
306 306  
307 -This data field shows if this packet is generated by interrupt or not. [[Click here>>path:#H3.2SetInterruptMode]] for the hardware and software set up.
308 308  
277 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
309 309  
279 +
310 310  **Example:**
311 311  
312 312  0x00: Normal uplink packet.
... ... @@ -317,6 +317,7 @@
317 317  
318 318  === 2.3.6 Message Type ===
319 319  
290 +
320 320  (((
321 321  For a normal uplink payload, the message type is always 0x01.
322 322  )))
... ... @@ -326,13 +326,14 @@
326 326  )))
327 327  
328 328  
329 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
330 -|=**Message Type Code**|=**Description**|=**Payload**
331 -|0x01|Normal Uplink|[[Normal Uplink Payload>>path:#H2.3200BUplinkPayload]]
332 -|0x02|Reply configures info|[[Configure Info Payload>>path:#H3.4GetFirmwareVersionInfo]]
333 -|0x03|Reply Calibration Info|[[Calibration Payload>>path:#H2.7Calibration]]
300 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:499px" %)
301 +|=(% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload**
302 +|(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
303 +|(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
304 +|(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
334 334  
335 335  
307 +
336 336  === 2.3.7 Decode payload in The Things Network ===
337 337  
338 338  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -345,7 +345,7 @@
345 345  )))
346 346  
347 347  (((
348 -LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
320 +LSPH01 TTN Payload Decoder:  [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
349 349  )))
350 350  
351 351  
... ... @@ -352,12 +352,14 @@
352 352  
353 353  == 2.4 Uplink Interval ==
354 354  
355 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
356 356  
328 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
357 357  
358 358  
331 +
359 359  == 2.5 ​Show Data in DataCake IoT Server ==
360 360  
334 +
361 361  (((
362 362  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
363 363  )))
... ... @@ -400,7 +400,7 @@
400 400  )))
401 401  
402 402  (((
403 -Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
377 +Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
404 404  )))
405 405  
406 406  
... ... @@ -421,8 +421,10 @@
421 421  
422 422  == 2.6 Installation and Maintain ==
423 423  
398 +
424 424  === 2.6.1 Before measurement ===
425 425  
401 +
426 426  (((
427 427  (((
428 428  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
... ... @@ -440,6 +440,8 @@
440 440  
441 441  (((
442 442  [[image:1654592946732-634.png]]
419 +
420 +
443 443  )))
444 444  
445 445  (((
... ... @@ -451,7 +451,7 @@
451 451  )))
452 452  
453 453  (((
454 -Slowly insert the probe to the measure point. Dont use large force which will break the probe. Make sure not shake when inserting.
432 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting.
455 455  )))
456 456  
457 457  (((
... ... @@ -478,6 +478,7 @@
478 478  
479 479  === 2.6.3 Maintain Probe ===
480 480  
459 +
481 481  1. (((
482 482  pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
483 483  )))
... ... @@ -502,6 +502,7 @@
502 502  
503 503  == 2.7 Calibration ==
504 504  
484 +
505 505  (((
506 506  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
507 507  )))
... ... @@ -516,11 +516,9 @@
516 516  (% style="color:#037691" %)**Calibration Payload**
517 517  
518 518  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
519 -|(((
520 -**Size**
521 -
522 -**(bytes)**
523 -)))|**1**|**1**|**1**|**7**|**1**
499 +|=(% style="width: 62.5px;" %)(((
500 +**Size (bytes)**
501 +)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1**
524 524  |**Value**|(((
525 525  PH4
526 526  
... ... @@ -530,7 +530,7 @@
530 530  
531 531  Calibrate value
532 532  )))|Reserve|(((
533 -[[Message Type>>path:#H2.3.6MessageType]]
511 +[[Message Type>>||anchor="H2.3.6MessageType"]]
534 534  
535 535  Always 0x03
536 536  )))
... ... @@ -546,13 +546,16 @@
546 546  
547 547  == 2.8 Frequency Plans ==
548 548  
527 +
549 549  (((
550 550  The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
551 551  )))
552 552  
553 553  
533 +
554 554  === 2.8.1 EU863-870 (EU868) ===
555 555  
536 +
556 556  (((
557 557  (% style="color:blue" %)**Uplink:**
558 558  )))
... ... @@ -613,6 +613,7 @@
613 613  
614 614  === 2.8.2 US902-928(US915) ===
615 615  
597 +
616 616  (((
617 617  Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
618 618  )))
... ... @@ -626,12 +626,13 @@
626 626  )))
627 627  
628 628  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
629 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
611 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
630 630  
631 631  
632 632  
633 633  === 2.8.3 CN470-510 (CN470) ===
634 634  
617 +
635 635  (((
636 636  Used in China, Default use CHE=1
637 637  )))
... ... @@ -720,6 +720,7 @@
720 720  
721 721  === 2.8.4 AU915-928(AU915) ===
722 722  
706 +
723 723  (((
724 724  Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
725 725  )))
... ... @@ -737,10 +737,13 @@
737 737  )))
738 738  
739 739  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
740 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
724 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
741 741  
726 +
727 +
742 742  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
743 743  
730 +
744 744  (((
745 745  (% style="color:blue" %)**Default Uplink channel:**
746 746  )))
... ... @@ -849,6 +849,7 @@
849 849  
850 850  === 2.8.6 KR920-923 (KR920) ===
851 851  
839 +
852 852  (((
853 853  (% style="color:blue" %)**Default channel:**
854 854  )))
... ... @@ -921,6 +921,7 @@
921 921  
922 922  === 2.8.7 IN865-867 (IN865) ===
923 923  
912 +
924 924  (((
925 925  (% style="color:blue" %)**Uplink:**
926 926  )))
... ... @@ -957,6 +957,7 @@
957 957  
958 958  == 2.9 LED Indicator ==
959 959  
949 +
960 960  The LSPH01 has an internal LED which is to show the status of different state.
961 961  
962 962  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
... ... @@ -964,15 +964,12 @@
964 964  
965 965  
966 966  
967 -
968 968  == 2.10 ​Firmware Change Log ==
969 969  
970 970  
971 -**Firmware download link:**
960 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]]
972 972  
973 -[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
974 974  
975 -
976 976  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
977 977  
978 978  
... ... @@ -979,12 +979,13 @@
979 979  
980 980  = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
981 981  
969 +
982 982  (((
983 983  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
984 984  )))
985 985  
986 986  * (((
987 -AT Command Connection: See [[FAQ>>path:#H6.FAQ]].
975 +AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
988 988  )))
989 989  * (((
990 990  LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
... ... @@ -1010,7 +1010,7 @@
1010 1010  )))
1011 1011  
1012 1012  (((
1013 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1001 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1014 1014  )))
1015 1015  
1016 1016  (((
... ... @@ -1029,6 +1029,7 @@
1029 1029  
1030 1030  == 3.1 Set Transmit Interval Time ==
1031 1031  
1020 +
1032 1032  Feature: Change LoRaWAN End Node Transmit Interval.
1033 1033  
1034 1034  (% style="color:#037691" %)**AT Command: AT+TDC**
... ... @@ -1036,7 +1036,6 @@
1036 1036  [[image:image-20220607171554-8.png]]
1037 1037  
1038 1038  
1039 -
1040 1040  (((
1041 1041  (% style="color:#037691" %)**Downlink Command: 0x01**
1042 1042  )))
... ... @@ -1054,16 +1054,20 @@
1054 1054  )))
1055 1055  * (((
1056 1056  Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1057 -)))
1058 1058  
1059 1059  
1047 +
1048 +
1049 +)))
1050 +
1060 1060  == 3.2 Set Interrupt Mode ==
1061 1061  
1053 +
1062 1062  Feature, Set Interrupt mode for GPIO_EXIT.
1063 1063  
1064 1064  (% style="color:#037691" %)**AT Command: AT+INTMOD**
1065 1065  
1066 -[[image:image-20220607171716-9.png]]
1058 +[[image:image-20220610105907-1.png]]
1067 1067  
1068 1068  
1069 1069  (((
... ... @@ -1093,12 +1093,14 @@
1093 1093  
1094 1094  == 3.3 Calibrate Sensor ==
1095 1095  
1096 -Detail See [[Calibration Guide>>path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands
1097 1097  
1089 +Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
1098 1098  
1099 1099  
1092 +
1100 1100  == 3.4 Get Firmware Version Info ==
1101 1101  
1095 +
1102 1102  Feature: use downlink to get firmware version.
1103 1103  
1104 1104  (% style="color:#037691" %)**Downlink Command: 0x26**
... ... @@ -1125,14 +1125,14 @@
1125 1125  
1126 1126  Version
1127 1127  )))|Sensor Type|Reserve|(((
1128 -[[Message Type>>path:#H2.3.6MessageType]]
1122 +[[Message Type>>||anchor="H2.3.6MessageType"]]
1129 1129  Always 0x02
1130 1130  )))
1131 1131  
1132 -**Software Type**: Always 0x03 for LSPH01
1126 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01
1133 1133  
1134 1134  
1135 -**Frequency Band**:
1129 +(% style="color:#037691" %)**Frequency Band**:
1136 1136  
1137 1137  *0x01: EU868
1138 1138  
... ... @@ -1155,13 +1155,13 @@
1155 1155  *0xa0: AS923-3
1156 1156  
1157 1157  
1158 -**Sub-Band**: value 0x00 ~~ 0x08
1152 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08
1159 1159  
1160 1160  
1161 -**Firmware Version**: 0x0100, Means: v1.0.0 version
1155 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
1162 1162  
1163 1163  
1164 -**Sensor Type**:
1158 +(% style="color:#037691" %)**Sensor Type**:
1165 1165  
1166 1166  0x01: LSE01
1167 1167  
... ... @@ -1181,14 +1181,18 @@
1181 1181  
1182 1182  = 4. Battery & How to replace =
1183 1183  
1178 +
1184 1184  == 4.1 Battery Type ==
1185 1185  
1181 +
1186 1186  (((
1187 1187  LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1188 1188  )))
1189 1189  
1190 1190  (((
1191 -The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
1187 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1188 +
1189 +
1192 1192  )))
1193 1193  
1194 1194  [[image:1654593587246-335.png]]
... ... @@ -1202,6 +1202,7 @@
1202 1202  
1203 1203  == 4.2 Replace Battery ==
1204 1204  
1203 +
1205 1205  (((
1206 1206  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
1207 1207  )))
... ... @@ -1214,6 +1214,7 @@
1214 1214  
1215 1215  == 4.3 Power Consumption Analyze ==
1216 1216  
1216 +
1217 1217  (((
1218 1218  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
1219 1219  )))
... ... @@ -1223,12 +1223,12 @@
1223 1223  )))
1224 1224  
1225 1225  
1226 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1226 +(% style="color:#037691" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1227 1227  
1228 1228  [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1229 1229  
1230 1230  
1231 -**Step 2**: Open it and choose
1231 +(% style="color:#037691" %)**Step 2**(%%): Open it and choose
1232 1232  
1233 1233  * Product Model
1234 1234  * Uplink Interval
... ... @@ -1242,13 +1242,13 @@
1242 1242  The battery related documents as below:
1243 1243  
1244 1244  * (((
1245 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1245 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
1246 1246  )))
1247 1247  * (((
1248 1248  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1249 1249  )))
1250 1250  * (((
1251 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1251 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
1252 1252  )))
1253 1253  
1254 1254  [[image:image-20220607172042-11.png]]
... ... @@ -1257,6 +1257,7 @@
1257 1257  
1258 1258  === 4.3.1 ​Battery Note ===
1259 1259  
1260 +
1260 1260  (((
1261 1261  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
1262 1262  )))
... ... @@ -1265,12 +1265,13 @@
1265 1265  
1266 1266  === ​4.3.2 Replace the battery ===
1267 1267  
1269 +
1268 1268  (((
1269 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there wont be voltage drop between battery and main board.
1271 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
1270 1270  )))
1271 1271  
1272 1272  (((
1273 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user cant find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1275 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1274 1274  )))
1275 1275  
1276 1276  
... ... @@ -1277,12 +1277,16 @@
1277 1277  
1278 1278  = 5. Use AT Command =
1279 1279  
1282 +
1280 1280  == 5.1 Access AT Commands ==
1281 1281  
1285 +
1282 1282  LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
1283 1283  
1288 +
1284 1284  [[image:1654593668970-604.png]]
1285 1285  
1291 +
1286 1286  **Connection:**
1287 1287  
1288 1288  (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
... ... @@ -1299,15 +1299,16 @@
1299 1299  
1300 1300   [[image:1654593712276-618.png]]
1301 1301  
1302 -Valid AT Command please check [[Configure Device>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]].
1308 +Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]].
1303 1303  
1304 1304  
1305 -
1306 1306  = 6. FAQ =
1307 1307  
1313 +
1308 1308  == 6.1 How to change the LoRa Frequency Bands/Region ==
1309 1309  
1310 -You can follow the instructions for [[how to upgrade image>>path:#H2.10200BFirmwareChangeLog]].
1316 +
1317 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1311 1311  When downloading the images, choose the required image file for download. ​
1312 1312  
1313 1313  
... ... @@ -1314,14 +1314,17 @@
1314 1314  
1315 1315  = 7. Trouble Shooting =
1316 1316  
1317 -== 7.1 AT Commands input doesn’t work ==
1318 1318  
1319 -In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1325 +== 7.1 AT Commands input doesn't work ==
1320 1320  
1321 1321  
1328 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1322 1322  
1330 +
1331 +
1323 1323  = 8. Order Info =
1324 1324  
1334 +
1325 1325  Part Number: (% style="color:blue" %)**LSPH01-XX**
1326 1326  
1327 1327  
... ... @@ -1337,7 +1337,6 @@
1337 1337  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1338 1338  
1339 1339  
1340 -
1341 1341  = 9. ​Packing Info =
1342 1342  
1343 1343  
... ... @@ -1353,9 +1353,9 @@
1353 1353  * Weight / pcs : g
1354 1354  
1355 1355  
1356 -
1357 1357  = 10. ​Support =
1358 1358  
1367 +
1359 1359  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1360 1360  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
1361 1361  
image-20220610105907-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +15.5 KB
Content