Last modified by Xiaoling on 2025/04/25 14:08

From version 72.3
edited by Xiaoling
on 2022/06/07 17:22
Change comment: There is no comment for this version
To version 98.9
edited by Xiaoling
on 2022/08/18 16:33
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,62 +4,7 @@
4 4  
5 5  
6 6  
7 -**Contents:**
8 8  
9 -* [[1. Introduction>>path:#H1.Introduction]]
10 -** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 -** [[​1.2 Features>>path:#H200B1.2Features]]
12 -** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 -** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 -** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 -* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 -** [[2.1 How it works>>path:#H2.1Howitworks]]
17 -** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 -** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 -*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 -*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 -*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 -*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 -*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 -*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 -*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 -** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 -** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 -** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 -*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 -*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 -*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 -** [[2.7 Calibration>>path:#H2.7Calibration]]
33 -** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 -*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 -*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 -*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 -*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 -*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 -*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 -*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 -** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 -** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 -* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 -** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 -** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 -** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 -** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 -* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 -** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 -** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 -** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 -*** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 -*** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 -* [[5. Use AT Command>>path:#H5.UseATCommand]]
55 -** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 -* [[6. FAQ>>path:#H6.FAQ]]
57 -** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 -* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 -** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 -* [[8. Order Info>>path:#H8.OrderInfo]]
61 -* [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 -* [[10. ​Support>>path:#H10.A0200BSupport]]
63 63  
64 64  
65 65  
... ... @@ -68,21 +68,45 @@
68 68  
69 69  
70 70  
16 +**Table of Contents:**
71 71  
18 +{{toc/}}
72 72  
20 +
21 +
22 +
23 +
24 +
25 +
26 +
27 +
28 +
73 73  = 1. Introduction =
74 74  
31 +
75 75  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
76 76  
34 +(((
35 +
36 +
77 77  The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
38 +)))
78 78  
40 +(((
79 79  LSPH01 probe is made by Solid AgCl reference electrode and Pure metal pH sensitive electrode. It can detect soil's** (% style="color:#4f81bd" %)pH (%%)**with high accuracy and stable value. The LSPH01 probe can be buried into soil for long time use.
42 +)))
80 80  
44 +(((
81 81  The LoRa wireless technology used in LSPH01 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
46 +)))
82 82  
48 +(((
83 83  LSPH01 is powered by (% style="color:#4f81bd" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
50 +)))
84 84  
52 +(((
85 85  Each LSPH01 is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
54 +)))
86 86  
87 87  
88 88  [[image:1654592435432-887.png]]
... ... @@ -89,8 +89,10 @@
89 89  
90 90  
91 91  
61 +
92 92  == ​1.2 Features ==
93 93  
64 +
94 94  * LoRaWAN 1.0.3 Class A
95 95  * Ultra-low power consumption
96 96  * Monitor soil pH with temperature compensation.
... ... @@ -106,6 +106,9 @@
106 106  * 8500mAh Battery for long term use
107 107  
108 108  
80 +
81 +
82 +
109 109  == 1.3 Probe Specification ==
110 110  
111 111  
... ... @@ -127,13 +127,20 @@
127 127  * Length: 3.5 meters
128 128  
129 129  
104 +
105 +
106 +
130 130  == 1.4 ​Applications ==
131 131  
109 +
132 132  * Smart Agriculture
133 133  
134 134  
113 +
114 +
135 135  == 1.5 Pin mapping and power on ==
136 136  
117 +
137 137  [[image:1654592472094-134.png]]
138 138  
139 139  
... ... @@ -140,19 +140,23 @@
140 140  
141 141  = 2. Configure LSPH01 to connect to LoRaWAN network =
142 142  
124 +
143 143  == 2.1 How it works ==
144 144  
127 +
145 145  (((
146 146  The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
147 147  )))
148 148  
149 149  (((
150 -In case you cant set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>path:#H5.UseATCommand]]to set the keys in the LSPH01.
133 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
151 151  )))
152 152  
153 153  
137 +
154 154  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
155 155  
140 +
156 156  (((
157 157  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
158 158  )))
... ... @@ -159,10 +159,14 @@
159 159  
160 160  (((
161 161  [[image:1654592492399-921.png]]
147 +
148 +
162 162  )))
163 163  
164 164  (((
165 165  The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
153 +
154 +
166 166  )))
167 167  
168 168  (((
... ... @@ -186,11 +186,13 @@
186 186  [[image:1654592600093-601.png]]
187 187  
188 188  
178 +
189 189  **Add APP EUI and DEV EUI**
190 190  
191 191  [[image:1654592619856-881.png]]
192 192  
193 193  
184 +
194 194  **Add APP EUI in the application**
195 195  
196 196  [[image:1654592632656-512.png]]
... ... @@ -210,8 +210,12 @@
210 210  [[image:image-20220607170442-2.png]]
211 211  
212 212  
204 +(((
213 213  (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
214 214  
207 +
208 +)))
209 +
215 215  [[image:1654592697690-910.png]]
216 216  
217 217  
... ... @@ -218,26 +218,31 @@
218 218  
219 219  == 2.3 ​Uplink Payload ==
220 220  
216 +
217 +(((
221 221  LSPH01 will uplink payload via LoRaWAN with below payload format: 
219 +)))
222 222  
221 +(((
223 223  Uplink payload includes in total 11 bytes.
223 +)))
224 224  
225 +(((
225 225  Normal uplink payload:
227 +)))
226 226  
227 227  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
228 -|(((
229 -**Size**
230 +|=(% style="width: 62.5px;" %)(((
231 +**Size (bytes)**
232 +)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1**
233 +|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)(((
234 +[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
230 230  
231 -**(bytes)**
232 -)))|**2**|**2**|**2**|**2**|**1**|**1**|**1**
233 -|**Value**|[[BAT>>path:#H2.3.1BatteryInfo]]|(((
234 -[[Temperature>>path:#H2.3.2DS18B20Temperaturesensor]]
235 -
236 -[[(Optional)>>path:#H2.3.2DS18B20Temperaturesensor]]
237 -)))|[[Soil pH>>path:#H2.3.3SoilpH]]|[[Soil Temperature>>path:#H2.3.4SoilTemperature]]|(((
238 -[[Digital Interrupt (Optional)>>path:#H2.3.5InterruptPin]]
236 +[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
237 +)))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
238 +[[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
239 239  )))|Reserve|(((
240 -[[Message Type>>path:#H2.3.6MessageType]]
240 +[[Message Type>>||anchor="H2.3.6MessageType"]]
241 241  )))
242 242  
243 243  [[image:1654592721645-318.png]]
... ... @@ -257,6 +257,7 @@
257 257  
258 258  === 2.3.2 DS18B20 Temperature sensor ===
259 259  
260 +
260 260  This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
261 261  
262 262  
... ... @@ -270,6 +270,7 @@
270 270  
271 271  === 2.3.3 Soil pH ===
272 272  
274 +
273 273  Range: 0 ~~ 14 pH
274 274  
275 275  **Example:**
... ... @@ -280,6 +280,7 @@
280 280  
281 281  === 2.3.4 Soil Temperature ===
282 282  
285 +
283 283  Get Soil Temperature 
284 284  
285 285  
... ... @@ -293,9 +293,10 @@
293 293  
294 294  === 2.3.5 Interrupt Pin ===
295 295  
296 -This data field shows if this packet is generated by interrupt or not. [[Click here>>path:#H3.2SetInterruptMode]] for the hardware and software set up.
297 297  
300 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
298 298  
302 +
299 299  **Example:**
300 300  
301 301  0x00: Normal uplink packet.
... ... @@ -306,19 +306,26 @@
306 306  
307 307  === 2.3.6 Message Type ===
308 308  
313 +
314 +(((
309 309  For a normal uplink payload, the message type is always 0x01.
316 +)))
310 310  
318 +(((
311 311  Valid Message Type:
320 +)))
312 312  
313 313  
314 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
315 -|**Message Type Code**|**Description**|**Payload**
316 -|0x01|Normal Uplink|[[Normal Uplink Payload>>path:#H2.3200BUplinkPayload]]
317 -|0x02|Reply configures info|[[Configure Info Payload>>path:#H3.4GetFirmwareVersionInfo]]
318 -|0x03|Reply Calibration Info|[[Calibration Payload>>path:#H2.7Calibration]]
323 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:499px" %)
324 +|=(% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload**
325 +|(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
326 +|(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
327 +|(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
319 319  
320 320  
321 321  
331 +
332 +
322 322  === 2.3.7 Decode payload in The Things Network ===
323 323  
324 324  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -331,7 +331,7 @@
331 331  )))
332 332  
333 333  (((
334 -LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
345 +LSPH01 TTN Payload Decoder:  [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
335 335  )))
336 336  
337 337  
... ... @@ -338,18 +338,29 @@
338 338  
339 339  == 2.4 Uplink Interval ==
340 340  
341 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
342 342  
353 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
343 343  
344 344  
356 +
345 345  == 2.5 ​Show Data in DataCake IoT Server ==
346 346  
359 +
360 +(((
347 347  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
362 +)))
348 348  
364 +(((
365 +
366 +)))
349 349  
368 +(((
350 350  (% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.**
370 +)))
351 351  
372 +(((
352 352  (% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:**
374 +)))
353 353  
354 354  
355 355  [[image:1654592790040-760.png]]
... ... @@ -372,9 +372,13 @@
372 372  [[image:1654592856403-259.png]]
373 373  
374 374  
397 +(((
375 375  (% style="color:blue" %)**Step 5**(%%)**: add payload decode**
399 +)))
376 376  
377 -Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
401 +(((
402 +Download Datacake decoder from: [[https:~~/~~/www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0>>url:https://www.dropbox.com/sh/pj7cgmgqg3gx3ta/AABYFbg1DVOOR9Hmr1mLSBkga?dl=0]]
403 +)))
378 378  
379 379  
380 380  [[image:1654592878525-845.png]]
... ... @@ -394,11 +394,15 @@
394 394  
395 395  == 2.6 Installation and Maintain ==
396 396  
423 +
397 397  === 2.6.1 Before measurement ===
398 398  
426 +
399 399  (((
428 +(((
400 400  If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
401 401  )))
431 +)))
402 402  
403 403  
404 404  
... ... @@ -405,29 +405,53 @@
405 405  === 2.6.2 Measurement ===
406 406  
407 407  
438 +(((
408 408  (% style="color:#4f81bd" %)**Measurement the soil surface:**
440 +)))
409 409  
442 +(((
410 410  [[image:1654592946732-634.png]]
411 411  
445 +
446 +)))
447 +
448 +(((
412 412  Choose the proper measuring position. Split the surface soil according to the measured deep.
450 +)))
413 413  
452 +(((
414 414  Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things.
454 +)))
415 415  
416 -Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting.
456 +(((
457 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting.
458 +)))
417 417  
460 +(((
418 418  Put soil over the probe after insert. And start to measure.
462 +)))
419 419  
464 +(((
465 +
466 +)))
420 420  
468 +(((
421 421  (% style="color:#4f81bd" %)**Measurement inside soil:**
470 +)))
422 422  
472 +(((
423 423  Dig a hole with diameter > 20CM.
474 +)))
424 424  
476 +(((
425 425  Insert the probe inside, method like measure the surface.
478 +)))
426 426  
427 427  
428 428  
429 429  === 2.6.3 Maintain Probe ===
430 430  
484 +
431 431  1. (((
432 432  pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
433 433  )))
... ... @@ -452,9 +452,14 @@
452 452  
453 453  == 2.7 Calibration ==
454 454  
509 +
510 +(((
455 455  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
512 +)))
456 456  
514 +(((
457 457  After stable, user can use below command to calibrate.
516 +)))
458 458  
459 459  [[image:image-20220607171149-4.png]]
460 460  
... ... @@ -461,12 +461,10 @@
461 461  
462 462  (% style="color:#037691" %)**Calibration Payload**
463 463  
464 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
465 -|(((
466 -**Size**
467 -
468 -**(bytes)**
469 -)))|**1**|**1**|**1**|**7**|**1**
523 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
524 +|=(% style="width: 62.5px;" %)(((
525 +**Size (bytes)**
526 +)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1**
470 470  |**Value**|(((
471 471  PH4
472 472  
... ... @@ -476,7 +476,7 @@
476 476  
477 477  Calibrate value
478 478  )))|Reserve|(((
479 -[[Message Type>>path:#H2.3.6MessageType]]
536 +[[Message Type>>||anchor="H2.3.6MessageType"]]
480 480  
481 481  Always 0x03
482 482  )))
... ... @@ -492,46 +492,80 @@
492 492  
493 493  
494 494  
552 +
495 495  == 2.8 Frequency Plans ==
496 496  
555 +
497 497  (((
498 498  The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
499 499  )))
500 500  
501 501  
561 +
502 502  === 2.8.1 EU863-870 (EU868) ===
503 503  
564 +
565 +(((
504 504  (% style="color:blue" %)**Uplink:**
567 +)))
505 505  
569 +(((
506 506  868.1 - SF7BW125 to SF12BW125
571 +)))
507 507  
573 +(((
508 508  868.3 - SF7BW125 to SF12BW125 and SF7BW250
575 +)))
509 509  
577 +(((
510 510  868.5 - SF7BW125 to SF12BW125
579 +)))
511 511  
581 +(((
512 512  867.1 - SF7BW125 to SF12BW125
583 +)))
513 513  
585 +(((
514 514  867.3 - SF7BW125 to SF12BW125
587 +)))
515 515  
589 +(((
516 516  867.5 - SF7BW125 to SF12BW125
591 +)))
517 517  
593 +(((
518 518  867.7 - SF7BW125 to SF12BW125
595 +)))
519 519  
597 +(((
520 520  867.9 - SF7BW125 to SF12BW125
599 +)))
521 521  
601 +(((
522 522  868.8 - FSK
603 +)))
523 523  
605 +(((
606 +
607 +)))
524 524  
609 +(((
525 525  (% style="color:blue" %)**Downlink:**
611 +)))
526 526  
613 +(((
527 527  Uplink channels 1-9 (RX1)
615 +)))
528 528  
617 +(((
529 529  869.525 - SF9BW125 (RX2 downlink only)
619 +)))
530 530  
531 531  
532 532  
533 533  === 2.8.2 US902-928(US915) ===
534 534  
625 +
535 535  (((
536 536  Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
537 537  )))
... ... @@ -545,58 +545,104 @@
545 545  )))
546 546  
547 547  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
548 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
639 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
549 549  
550 550  
551 551  
552 552  
644 +
553 553  === 2.8.3 CN470-510 (CN470) ===
554 554  
647 +
648 +(((
555 555  Used in China, Default use CHE=1
650 +)))
556 556  
652 +(((
557 557  (% style="color:blue" %)**Uplink:**
654 +)))
558 558  
656 +(((
559 559  486.3 - SF7BW125 to SF12BW125
658 +)))
560 560  
660 +(((
561 561  486.5 - SF7BW125 to SF12BW125
662 +)))
562 562  
664 +(((
563 563  486.7 - SF7BW125 to SF12BW125
666 +)))
564 564  
668 +(((
565 565  486.9 - SF7BW125 to SF12BW125
670 +)))
566 566  
672 +(((
567 567  487.1 - SF7BW125 to SF12BW125
674 +)))
568 568  
676 +(((
569 569  487.3 - SF7BW125 to SF12BW125
678 +)))
570 570  
680 +(((
571 571  487.5 - SF7BW125 to SF12BW125
682 +)))
572 572  
684 +(((
573 573  487.7 - SF7BW125 to SF12BW125
686 +)))
574 574  
688 +(((
689 +
690 +)))
575 575  
692 +(((
576 576  (% style="color:blue" %)**Downlink:**
694 +)))
577 577  
696 +(((
578 578  506.7 - SF7BW125 to SF12BW125
698 +)))
579 579  
700 +(((
580 580  506.9 - SF7BW125 to SF12BW125
702 +)))
581 581  
704 +(((
582 582  507.1 - SF7BW125 to SF12BW125
706 +)))
583 583  
708 +(((
584 584  507.3 - SF7BW125 to SF12BW125
710 +)))
585 585  
712 +(((
586 586  507.5 - SF7BW125 to SF12BW125
714 +)))
587 587  
716 +(((
588 588  507.7 - SF7BW125 to SF12BW125
718 +)))
589 589  
720 +(((
590 590  507.9 - SF7BW125 to SF12BW125
722 +)))
591 591  
724 +(((
592 592  508.1 - SF7BW125 to SF12BW125
726 +)))
593 593  
728 +(((
594 594  505.3 - SF12BW125 (RX2 downlink only)
730 +)))
595 595  
596 596  
597 597  
598 598  === 2.8.4 AU915-928(AU915) ===
599 599  
736 +
600 600  (((
601 601  Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
602 602  )))
... ... @@ -614,120 +614,234 @@
614 614  )))
615 615  
616 616  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
617 -* Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
754 +* Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
618 618  
619 619  
620 620  
621 621  
759 +
622 622  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
623 623  
762 +
763 +(((
624 624  (% style="color:blue" %)**Default Uplink channel:**
765 +)))
625 625  
767 +(((
626 626  923.2 - SF7BW125 to SF10BW125
769 +)))
627 627  
771 +(((
628 628  923.4 - SF7BW125 to SF10BW125
773 +)))
629 629  
775 +(((
776 +
777 +)))
630 630  
779 +(((
631 631  (% style="color:blue" %)**Additional Uplink Channel**:
781 +)))
632 632  
783 +(((
633 633  (OTAA mode, channel added by JoinAccept message)
785 +)))
634 634  
787 +(((
788 +
789 +)))
635 635  
791 +(((
636 636  (% style="color:blue" %)**AS920~~AS923 for Japan, Malaysia, Singapore**:
793 +)))
637 637  
795 +(((
638 638  922.2 - SF7BW125 to SF10BW125
797 +)))
639 639  
799 +(((
640 640  922.4 - SF7BW125 to SF10BW125
801 +)))
641 641  
803 +(((
642 642  922.6 - SF7BW125 to SF10BW125
805 +)))
643 643  
807 +(((
644 644  922.8 - SF7BW125 to SF10BW125
809 +)))
645 645  
811 +(((
646 646  923.0 - SF7BW125 to SF10BW125
813 +)))
647 647  
815 +(((
648 648  922.0 - SF7BW125 to SF10BW125
817 +)))
649 649  
819 +(((
820 +
821 +)))
650 650  
823 +(((
651 651  (% style="color:blue" %)**AS923 ~~ AS925 for Brunei, Cambodia, Hong Kong, Indonesia, Laos, Taiwan, Thailand, Vietnam**:
825 +)))
652 652  
827 +(((
653 653  923.6 - SF7BW125 to SF10BW125
829 +)))
654 654  
831 +(((
655 655  923.8 - SF7BW125 to SF10BW125
833 +)))
656 656  
835 +(((
657 657  924.0 - SF7BW125 to SF10BW125
837 +)))
658 658  
839 +(((
659 659  924.2 - SF7BW125 to SF10BW125
841 +)))
660 660  
843 +(((
661 661  924.4 - SF7BW125 to SF10BW125
845 +)))
662 662  
847 +(((
663 663  924.6 - SF7BW125 to SF10BW125
849 +)))
664 664  
851 +(((
852 +
853 +)))
665 665  
855 +(((
666 666  (% style="color:blue" %)**Downlink:**
857 +)))
667 667  
859 +(((
668 668  Uplink channels 1-8 (RX1)
861 +)))
669 669  
863 +(((
670 670  923.2 - SF10BW125 (RX2)
865 +)))
671 671  
672 672  
673 673  
674 674  === 2.8.6 KR920-923 (KR920) ===
675 675  
871 +
872 +(((
676 676  (% style="color:blue" %)**Default channel:**
874 +)))
677 677  
876 +(((
678 678  922.1 - SF7BW125 to SF12BW125
878 +)))
679 679  
880 +(((
680 680  922.3 - SF7BW125 to SF12BW125
882 +)))
681 681  
884 +(((
682 682  922.5 - SF7BW125 to SF12BW125
886 +)))
683 683  
888 +(((
889 +
890 +)))
684 684  
892 +(((
685 685  (% style="color:blue" %)**Uplink: (OTAA mode, channel added by JoinAccept message)**
894 +)))
686 686  
896 +(((
687 687  922.1 - SF7BW125 to SF12BW125
898 +)))
688 688  
900 +(((
689 689  922.3 - SF7BW125 to SF12BW125
902 +)))
690 690  
904 +(((
691 691  922.5 - SF7BW125 to SF12BW125
906 +)))
692 692  
908 +(((
693 693  922.7 - SF7BW125 to SF12BW125
910 +)))
694 694  
912 +(((
695 695  922.9 - SF7BW125 to SF12BW125
914 +)))
696 696  
916 +(((
697 697  923.1 - SF7BW125 to SF12BW125
918 +)))
698 698  
920 +(((
699 699  923.3 - SF7BW125 to SF12BW125
922 +)))
700 700  
924 +(((
925 +
926 +)))
701 701  
928 +(((
702 702  (% style="color:blue" %)**Downlink:**
930 +)))
703 703  
932 +(((
704 704  Uplink channels 1-7(RX1)
934 +)))
705 705  
936 +(((
706 706  921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
938 +)))
707 707  
708 708  
709 709  
710 710  === 2.8.7 IN865-867 (IN865) ===
711 711  
944 +
945 +(((
712 712  (% style="color:blue" %)**Uplink:**
947 +)))
713 713  
949 +(((
714 714  865.0625 - SF7BW125 to SF12BW125
951 +)))
715 715  
953 +(((
716 716  865.4025 - SF7BW125 to SF12BW125
955 +)))
717 717  
957 +(((
718 718  865.9850 - SF7BW125 to SF12BW125
959 +)))
719 719  
961 +(((
962 +
963 +)))
720 720  
965 +(((
721 721  (% style="color:blue" %)**Downlink:**
967 +)))
722 722  
969 +(((
723 723  Uplink channels 1-3 (RX1)
971 +)))
724 724  
973 +(((
725 725  866.550 - SF10BW125 (RX2)
975 +)))
726 726  
727 727  
728 728  
729 729  == 2.9 LED Indicator ==
730 730  
981 +
731 731  The LSPH01 has an internal LED which is to show the status of different state.
732 732  
733 733  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
... ... @@ -736,14 +736,13 @@
736 736  
737 737  
738 738  
990 +
739 739  == 2.10 ​Firmware Change Log ==
740 740  
741 741  
742 -**Firmware download link:**
994 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0>>https://www.dropbox.com/sh/xtm5tw37mewaw99/AAD0uy06odmreQQ7vMzZYVIGa?dl=0]]
743 743  
744 -[[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
745 745  
746 -
747 747  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
748 748  
749 749  
... ... @@ -750,26 +750,51 @@
750 750  
751 751  = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
752 752  
1003 +(((
753 753  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
1005 +)))
754 754  
755 -* AT Command Connection: See [[FAQ>>path:#H6.FAQ]].
756 -* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
1007 +* (((
1008 +AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
1009 +)))
1010 +* (((
1011 +LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
1012 +)))
757 757  
1014 +(((
758 758  There are two kinds of commands to configure LSPH01, they are:
1016 +)))
759 759  
760 -* (% style="color:#4f81bd" %)** General Commands**.
1018 +* (((
1019 +(% style="color:#4f81bd" %)** General Commands**.
1020 +)))
761 761  
1022 +(((
762 762  These commands are to configure:
1024 +)))
763 763  
764 -* General system settings like: uplink interval.
765 -* LoRaWAN protocol & radio related command.
1026 +* (((
1027 +General system settings like: uplink interval.
1028 +)))
1029 +* (((
1030 +LoRaWAN protocol & radio related command.
1031 +)))
766 766  
767 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1033 +(((
1034 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1035 +)))
768 768  
1037 +(((
1038 +
1039 +)))
769 769  
770 -* (% style="color:#4f81bd" %)** Commands special design for LSPH01**
1041 +* (((
1042 +(% style="color:#4f81bd" %)** Commands special design for LSPH01**
1043 +)))
771 771  
1045 +(((
772 772  These commands only valid for LSPH01, as below:
1047 +)))
773 773  
774 774  
775 775  
... ... @@ -782,17 +782,27 @@
782 782  [[image:image-20220607171554-8.png]]
783 783  
784 784  
785 -
1060 +(((
786 786  (% style="color:#037691" %)**Downlink Command: 0x01**
1062 +)))
787 787  
1064 +(((
788 788  Format: Command Code (0x01) followed by 3 bytes time value.
1066 +)))
789 789  
1068 +(((
790 790  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
1070 +)))
791 791  
792 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
793 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1072 +* (((
1073 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1074 +)))
1075 +* (((
1076 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
794 794  
795 795  
1079 +
1080 +)))
796 796  
797 797  == 3.2 Set Interrupt Mode ==
798 798  
... ... @@ -800,24 +800,36 @@
800 800  
801 801  (% style="color:#037691" %)**AT Command: AT+INTMOD**
802 802  
803 -[[image:image-20220607171716-9.png]]
1088 +[[image:image-20220610105907-1.png]]
804 804  
805 805  
1091 +(((
806 806  (% style="color:#037691" %)**Downlink Command: 0x06**
1093 +)))
807 807  
1095 +(((
808 808  Format: Command Code (0x06) followed by 3 bytes.
1097 +)))
809 809  
1099 +(((
810 810  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
1101 +)))
811 811  
812 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
813 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1103 +* (((
1104 +Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1105 +)))
1106 +* (((
1107 +Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1108 +)))
814 814  
1110 +(((
1111 +
1112 +)))
815 815  
816 816  
817 -
818 818  == 3.3 Calibrate Sensor ==
819 819  
820 -Detail See [[Calibration Guide>>path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands
1117 +Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
821 821  
822 822  
823 823  
... ... @@ -832,7 +832,6 @@
832 832  * Reply to the confirmation package: 26 01
833 833  * Reply to non-confirmed packet: 26 00
834 834  
835 -
836 836  Device will send an uplink after got this downlink command. With below payload:
837 837  
838 838  Configures info payload:
... ... @@ -850,14 +850,14 @@
850 850  
851 851  Version
852 852  )))|Sensor Type|Reserve|(((
853 -[[Message Type>>path:#H2.3.6MessageType]]
1149 +[[Message Type>>||anchor="H2.3.6MessageType"]]
854 854  Always 0x02
855 855  )))
856 856  
857 -**Software Type**: Always 0x03 for LSPH01
1153 +(% style="color:#037691" %)**Software Type**(%%): Always 0x03 for LSPH01
858 858  
859 859  
860 -**Frequency Band**:
1156 +(% style="color:#037691" %)**Frequency Band**:
861 861  
862 862  *0x01: EU868
863 863  
... ... @@ -880,13 +880,13 @@
880 880  *0xa0: AS923-3
881 881  
882 882  
883 -**Sub-Band**: value 0x00 ~~ 0x08
1179 +(% style="color:#037691" %)**Sub-Band**(%%): value 0x00 ~~ 0x08
884 884  
885 885  
886 -**Firmware Version**: 0x0100, Means: v1.0.0 version
1182 +(% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
887 887  
888 888  
889 -**Sensor Type**:
1185 +(% style="color:#037691" %)**Sensor Type**:
890 890  
891 891  0x01: LSE01
892 892  
... ... @@ -913,7 +913,7 @@
913 913  )))
914 914  
915 915  (((
916 -The discharge curve is not linear so cant simply use percentage to show the battery level. Below is the battery performance.
1212 +The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
917 917  )))
918 918  
919 919  [[image:1654593587246-335.png]]
... ... @@ -948,12 +948,12 @@
948 948  )))
949 949  
950 950  
951 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1247 +(% style="color:#037691" %)**Step 1**(%%): Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
952 952  
953 953  [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
954 954  
955 955  
956 -**Step 2**: Open it and choose
1252 +(% style="color:#037691" %)**Step 2**(%%): Open it and choose
957 957  
958 958  * Product Model
959 959  * Uplink Interval
... ... @@ -967,13 +967,13 @@
967 967  The battery related documents as below:
968 968  
969 969  * (((
970 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1266 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
971 971  )))
972 972  * (((
973 973  [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
974 974  )))
975 975  * (((
976 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1272 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
977 977  )))
978 978  
979 979  [[image:image-20220607172042-11.png]]
... ... @@ -990,9 +990,13 @@
990 990  
991 991  === ​4.3.2 Replace the battery ===
992 992  
993 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
1289 +(((
1290 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
1291 +)))
994 994  
995 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1293 +(((
1294 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1295 +)))
996 996  
997 997  
998 998  
... ... @@ -1013,29 +1013,29 @@
1013 1013  (% style="background-color:yellow" %)** USB TTL RXD  <~-~-~-~-> UART_TXD**
1014 1014  
1015 1015  
1316 +(((
1016 1016  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below:
1318 +)))
1017 1017  
1018 1018  
1019 1019   [[image:1654593712276-618.png]]
1020 1020  
1021 -Valid AT Command please check [[Configure Device>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]].
1323 +Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]].
1022 1022  
1023 1023  
1024 -
1025 1025  = 6. FAQ =
1026 1026  
1027 1027  == 6.1 How to change the LoRa Frequency Bands/Region ==
1028 1028  
1029 -You can follow the instructions for [[how to upgrade image>>path:#H2.10200BFirmwareChangeLog]].
1330 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1030 1030  When downloading the images, choose the required image file for download. ​
1031 1031  
1032 1032  
1033 -
1034 1034  = 7. Trouble Shooting =
1035 1035  
1036 -== 7.1 AT Commands input doesnt work ==
1336 +== 7.1 AT Commands input doesn't work ==
1037 1037  
1038 -In the case if user can see the console output but cant type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1338 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1039 1039  
1040 1040  
1041 1041  
... ... @@ -1056,8 +1056,6 @@
1056 1056  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1057 1057  
1058 1058  
1059 -
1060 -
1061 1061  = 9. ​Packing Info =
1062 1062  
1063 1063  
... ... @@ -1072,6 +1072,7 @@
1072 1072  * Package Size / pcs : cm
1073 1073  * Weight / pcs : g
1074 1074  
1373 +
1075 1075  = 10. ​Support =
1076 1076  
1077 1077  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
image-20220610105907-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +15.5 KB
Content