<
From version < 107.1 >
edited by Bei Jinggeng
on 2024/08/02 17:02
To version < 104.1 >
edited by Bei Jinggeng
on 2024/03/30 17:44
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1244,7 +1244,7 @@
1244 1244  In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1245 1245  
1246 1246  
1247 -== 7.2 Possible reasons why the device is unresponsive: ==
1247 +== 5.Possible reasons why the device is unresponsive: ==
1248 1248  
1249 1249  
1250 1250  ​1. Check whether the battery voltage is lower than 2.8V
... ... @@ -1256,46 +1256,9 @@
1256 1256  [[image:image-20240330174406-3.png]]
1257 1257  ​
1258 1258  
1259 -== 7.3 The node cannot read the sensor data ==
1259 +(% class="wikigeneratedid" %)
1260 += =
1260 1260  
1261 -This may be caused by a software firmware(≤1.1.6 version) bug, which we fixed in the latest firmware (>1.0.0 version)
1262 -
1263 -The user can fix this problem via upgrade firmware.
1264 -
1265 -
1266 -By default, The latest firmware value of POWERIC is 1, while the 3322 version requires POWERIC to be set to 0 in order to function properly
1267 -
1268 -
1269 -* **//1. Check if the hardware version is 3322//**
1270 -
1271 -If the sensor hardware version is 3322 or earlier, the user can change the POWERIC value to 0 after a firmware upgrade using one of the following methods
1272 -
1273 -**a. Using AT command**
1274 -
1275 -(% class="box infomessage" %)
1276 -(((
1277 -AT+POWERIC=0.
1278 -)))
1279 -
1280 -
1281 -**b. Using Downlink**
1282 -
1283 -(% class="box infomessage" %)
1284 -(((
1285 -FF 00(AT+POWERIC=0).
1286 -)))
1287 -
1288 -
1289 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20240531090837-1.png?rev=1.1||alt="image-20240531090837-1.png"]]
1290 -
1291 -
1292 -Please check your hardware production date
1293 -
1294 -The first two digits are the week of the year, and the last two digits are the year.
1295 -
1296 -The number 3322 is the first batch we changed the power IC.
1297 -
1298 -
1299 1299  = 8. Order Info =
1300 1300  
1301 1301  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0