Changes for page LSPH01 -- LoRaWAN Soil pH Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 17:52
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -LSPH01 -LoRaWAN Soil pH Sensor User Manual1 +LSPH01-LoRaWAN Soil pH Sensor User Manual - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -64,6 +64,7 @@ 64 64 * IP68 rate for the Sensor Probe 65 65 * 8500mAh Battery for long term use 66 66 67 + 67 67 == 1.3 Probe Specification == 68 68 69 69 ... ... @@ -84,11 +84,13 @@ 84 84 * IP68 Protection 85 85 * Length: 3.5 meters 86 86 88 + 87 87 == 1.4 Applications == 88 88 89 89 90 90 * Smart Agriculture 91 91 94 + 92 92 == 1.5 Pin mapping and power on == 93 93 94 94 ... ... @@ -291,6 +291,7 @@ 291 291 |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]] 292 292 |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]] 293 293 297 + 294 294 === 2.3.7 Decode payload in The Things Network === 295 295 296 296 ... ... @@ -462,26 +462,15 @@ 462 462 == 2.7 Calibration == 463 463 464 464 465 -(% style="color:blue" %)**Step1 :**(%%)** Clean probe** 466 - 467 -user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks new, users can clean it to remove hydrochloric acid or other liquids from the surface. 468 - 469 -(% style="color:blue" %)**Step2 :**(%%)** Immerse the sensor in ph buffer solution to make the sensor values stable** 470 - 471 471 ((( 472 472 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 473 - 474 -(% style="color:red" %)**Note: Only one ph buffer with one of the ph values needs to be calibrated during calibration. Wait for the sensor measurement value to be stable, it does not need to be the same as the ph marked by the ph buffer** 475 - 476 - 477 -(% style="color:blue" %)**Step3 :**(%%)** The numerically stable sensors were calibrated using commands** 478 478 ))) 479 479 480 480 ((( 481 - User can use below command to calibrate.474 +After stable, user can use below command to calibrate. 482 482 483 483 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 484 -|(% style="background-color:#4 f81bd;20px" %)**pH buffer solution**|(% style="background-color:#4f81bd;0px" %)**AT Command to calibrate**|(% style="background-color:#4f81bd;45px" %)**Downlink Command**|(% style="background-color:#4f81bd;95px" %)**Read Cal Value**477 +|(% style="background-color:#4F81BD;color:white; width:115px" %)**pH buffer solution**|(% style="background-color:#4F81BD;color:white; width:145px" %)**AT Command to calibrate**|(% style="background-color:#4F81BD;color:white; width:150px" %)**Downlink Command**|(% style="background-color:#4F81BD;color:white; width:100px" %)**Read Cal Value** 485 485 |(% style="width:149px" %)4.00|(% style="width:197px" %)AT+PHCAL=4|(% style="width:206px" %)((( 486 486 0x13 04 487 487 Reply with Calibrate payload ... ... @@ -506,25 +506,13 @@ 506 506 ))) 507 507 ))) 508 508 509 -To use the AT COMMAND, refer to this link: 510 510 511 -* AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 512 - 513 -* AT Command via UART Connection : See [[UART Connection>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 514 - 515 -To use Downlink, take TTN as an example, please refer to this link: 516 - 517 -* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 518 - 519 -When the command is successfully used, the node sends a uplink. 520 -This is the payload for uplink 521 - 522 522 (% style="color:#037691" %)**Calibration Payload** 523 523 524 524 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:500px" %) 525 525 |=(% style="width: 60px;background-color:#4F81BD;color:white" %)((( 526 526 **Size(bytes)** 527 -)))|=(% style="width: 100px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 100px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 100px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 50px;background-color:#4F81BD;color:white" %)**7**|=(% style="width: 508 +)))|=(% style="width: 100px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 100px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 100px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 50px;background-color:#4F81BD;color:white" %)**7**|=(% style="width:90px;background-color:#4F81BD;color:white" %)**1** 528 528 |Value|((( 529 529 PH4 Calibrate value 530 530 )))|PH6.86 Calibrate value|((( ... ... @@ -544,13 +544,7 @@ 544 544 545 545 * Reply to non-confirmed packet: 14 00 546 546 547 -(% style="color:blue" %)**Step4 : **(%%)**After the calibration is completed, its measurement results in this ph buffer solution should be consistent with the numerical value of the command used in the calibration.** 548 548 549 -Examples: 550 -After using the command AT+PH=9 in 9.18ph buffer 551 -The readout returned by the sensor in 9.18ph buffer should be pH=9 552 - 553 - 554 554 == 2.8 Frequency Plans == 555 555 556 556 ... ... @@ -638,6 +638,7 @@ 638 638 639 639 * Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 640 640 616 + 641 641 === 2.8.3 CN470-510 (CN470) === 642 642 643 643 ... ... @@ -749,6 +749,7 @@ 749 749 750 750 * Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 751 751 728 + 752 752 === 2.8.5 AS920-923 & AS923-925 (AS923) === 753 753 754 754 ... ... @@ -965,6 +965,7 @@ 965 965 966 966 * Blink once when device transmit a packet. 967 967 945 + 968 968 == 2.10 Firmware Change Log == 969 969 970 970 ... ... @@ -1119,7 +1119,7 @@ 1119 1119 (% style="color:#037691" %)**Downlink Command: 0x26** 1120 1120 1121 1121 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:500px" %) 1122 -|(% style="background-color:#4 f81bd;f81bd;f81bd;f81bd;1100 +|(% style="background-color:#4F81BD;color:white; width:193px" %)**Downlink Control Type**|(% style="background-color:#4F81BD;color:white; width:57px" %)**FPort**|(% style="background-color:#4F81BD;color:white; width:91px" %)**Type Code**|(% style="background-color:#4F81BD;color:white; width:159px" %)**Downlink payload size(bytes)** 1123 1123 |(% style="width:193px" %)Get Firmware Version Info|(% style="width:57px" %)Any|(% style="width:91px" %)26|(% style="width:149px" %)2 1124 1124 1125 1125 * Reply to the confirmation package: 26 01 ... ... @@ -1131,7 +1131,7 @@ 1131 1131 Configures info payload: 1132 1132 1133 1133 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1134 -|(% style="background-color:#4 f81bd;f81bd;f81bd;f81bd;f81bd;f81bd;f81bd;f81bd;1112 +|(% style="background-color:#4F81BD;color:white; width:50px" %)**Size(bytes)**|(% style="background-color:#4F81BD;color:white; width:70px" %)**1**|(% style="background-color:#4F81BD;color:white; width:70px" %)**1**|(% style="background-color:#4F81BD;color:white; width:50px" %)**1**|(% style="background-color:#4F81BD;color:white; width:70px" %)**1**|(% style="background-color:#4F81BD;color:white; width:60px" %)**1**|(% style="background-color:#4F81BD;color:white; width:50px" %)**5**|(% style="background-color:#4F81BD;color:white; width:90px" %)**1** 1135 1135 |Value|Software Type|((( 1136 1136 Frequency 1137 1137 Band ... ... @@ -1244,21 +1244,6 @@ 1244 1244 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1245 1245 1246 1246 1247 -== 5.3 Possible reasons why the device is unresponsive: == 1248 - 1249 - 1250 -1. Check whether the battery voltage is lower than 2.8V 1251 -2. Check whether the jumper of the device is correctly connected 1252 - 1253 -[[image:image-20240330174400-2.png]] 1254 -3. Check whether the switch here of the device is at the ISP(The switch can operate normally only when it is in RUN) 1255 - 1256 -[[image:image-20240330174406-3.png]] 1257 - 1258 - 1259 -(% class="wikigeneratedid" %) 1260 -= = 1261 - 1262 1262 = 8. Order Info = 1263 1263 1264 1264 ... ... @@ -1276,6 +1276,7 @@ 1276 1276 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1277 1277 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1278 1278 1242 + 1279 1279 = 9. Packing Info = 1280 1280 1281 1281 ... ... @@ -1290,6 +1290,7 @@ 1290 1290 * Package Size / pcs : cm 1291 1291 * Weight / pcs : g 1292 1292 1257 + 1293 1293 = 10. Support = 1294 1294 1295 1295
- image-20240330174324-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -445.4 KB - Content
- image-20240330174400-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -445.4 KB - Content
- image-20240330174406-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -445.4 KB - Content