... ... @@ -1,1 +1,1 @@
1 -LSPH01 -- LoRaWAN Soil pH Sensor User Manual
1 +LSPH01-LoRaWAN Soil pH Sensor User Manual
Content
... ... @@ -471,7 +471,7 @@
471 471  (((
472 472  User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
473 473  
474 -(% style="color:red" %)**Note: Only one ph buffer with one of the ph values needs to be calibrated during calibration. Wait for the sensor measurement value to be stable, it does not need to be the same as the ph marked by the ph buffer**
474 +(% style="color:red" %)**NoteOnly one ph buffer with one of the ph values needs to be calibrated during calibration. Wait for the sensor measurement value to be stable, it does not need to be the same as the ph marked by the ph buffer**
475 475  
476 476  
477 477  (% style="color:blue" %)**Step3 :**(%%)** The numerically stable sensors were calibrated using commands**
... ... @@ -480,8 +480,8 @@
480 480  (((
481 481   User can use below command to calibrate.
482 482  
483 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
484 -|(% style="background-color:#4f81bd; color:white; width:120px" %)**pH buffer solution**|(% style="background-color:#4f81bd; color:white; width:150px" %)**AT Command to calibrate**|(% style="background-color:#4f81bd; color:white; width:145px" %)**Downlink Command**|(% style="background-color:#4f81bd; color:white; width:95px" %)**Read Cal Value**
483 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
484 +|(% style="background-color:#4f81bd; color:white; width:120px" %)**pH buffer solution**|(% style="background-color:#4f81bd; color:white; width:150px" %)**AT Command to calibrate**|(% style="background-color:#4f81bd; color:white; width:150px" %)**Downlink Command**|(% style="background-color:#4f81bd; color:white; width:100px" %)**Read Cal Value**
485 485  |(% style="width:149px" %)4.00|(% style="width:197px" %)AT+PHCAL=4|(% style="width:206px" %)(((
486 486  0x13 04
487 487  Reply with Calibrate payload
... ... @@ -521,7 +521,7 @@
521 521  
522 522  (% style="color:#037691" %)**Calibration Payload**
523 523  
524 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:500px" %)
524 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %)
525 525  |=(% style="width: 60px;background-color:#4F81BD;color:white" %)(((
526 526  **Size(bytes)**
527 527  )))|=(% style="width: 100px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 100px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 100px;background-color:#4F81BD;color:white" %)**1**|=(% style="width: 50px;background-color:#4F81BD;color:white" %)**7**|=(% style="width: 90px;background-color:#4F81BD;color:white" %)**1**
... ... @@ -536,8 +536,8 @@
536 536  
537 537  User can also send 0x14 downlink command to poll the current calibration payload.
538 538  
539 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:480px" %)
540 -|=(% style="width: 183px; background-color:#4F81BD;color:white" %)**Downlink Control Type**|=(% style="width: 55px; background-color:#4F81BD;color:white" %)FPort|=(% style="width: 93px; background-color:#4F81BD;color:white" %)**Type Code**|=(% style="width: 149px; background-color:#4F81BD;color:white" %)**Downlink payload size(bytes)**
539 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:480px" %)
540 +|=(% style="width: 183px; background-color:#4F81BD;color:white" %)**Downlink Control Type**|=(% style="width: 55px; background-color:#4F81BD;color:white" %)FPort|=(% style="width: 93px; background-color:#4F81BD;color:white" %)**Type Code**|=(% style="width: 146px; background-color:#4F81BD;color:white" %)**Downlink payload size(bytes)**
541 541  |(% style="width:183px" %)Get Calibration Version Info|(% style="width:55px" %)Any|(% style="width:93px" %)14|(% style="width:146px" %)2
542 542  
543 543  * Reply to the confirmation package: 14 01
... ... @@ -544,13 +544,12 @@
544 544  
545 545  * Reply to non-confirmed packet: 14 00
546 546  
547 -(% style="color:blue" %)**Step4 : **(%%)**After the calibration is completed, its measurement results in this ph buffer solution should be consistent with the numerical value of the command used in the calibration.**
547 +(% style="color:blue" %)**Step4**(%%)**After the calibration is completed, its measurement results in this ph buffer solution should be consistent with the numerical value of the command used in the calibration.**
548 548  
549 549  Examples:
550 550  After using the command AT+PH=9 in 9.18ph buffer
551 551  The readout returned by the sensor in 9.18ph buffer should be pH=9
552 552  
553 -
554 554  == 2.8 Frequency Plans ==
555 555  
556 556  
image-20240330174324-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -445.4 KB
Content
image-20240330174400-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -445.4 KB
Content
image-20240330174406-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -445.4 KB
Content