From version < 95.2 >
edited by Xiaoling
on 2022/06/10 11:03
To version < 93.7 >
edited by Xiaoling
on 2022/06/10 10:32
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -913,10 +913,10 @@
913 913  
914 914  
915 915  
916 -= 4.  Configure LLDS12 via AT Command or LoRaWAN Downlink =
916 += 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
917 917  
918 918  (((
919 -Use can configure LLDS12 via AT Command or LoRaWAN Downlink.
919 +Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
920 920  )))
921 921  
922 922  * (((
... ... @@ -927,9 +927,7 @@
927 927  )))
928 928  
929 929  (((
930 -
931 -
932 -There are two kinds of commands to configure LLDS12, they are:
930 +There are two kinds of commands to configure LSPH01, they are:
933 933  )))
934 934  
935 935  * (((
... ... @@ -948,7 +948,7 @@
948 948  )))
949 949  
950 950  (((
951 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
949 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
952 952  )))
953 953  
954 954  (((
... ... @@ -956,16 +956,16 @@
956 956  )))
957 957  
958 958  * (((
959 -(% style="color:#4f81bd" %)** Commands special design for LLDS12**
957 +(% style="color:#4f81bd" %)** Commands special design for LSPH01**
960 960  )))
961 961  
962 962  (((
963 -These commands only valid for LLDS12, as below:
961 +These commands only valid for LSPH01, as below:
964 964  )))
965 965  
966 966  
967 967  
968 -== 4.1  Set Transmit Interval Time ==
966 +== 3.1 Set Transmit Interval Time ==
969 969  
970 970  Feature: Change LoRaWAN End Node Transmit Interval.
971 971  
... ... @@ -997,17 +997,15 @@
997 997  
998 998  )))
999 999  
1000 -== 4.2  Set Interrupt Mode ==
998 +== 3.2 Set Interrupt Mode ==
1001 1001  
1002 1002  Feature, Set Interrupt mode for GPIO_EXIT.
1003 1003  
1004 1004  (% style="color:#037691" %)**AT Command: AT+INTMOD**
1005 1005  
1006 -[[image:image-20220610105806-2.png]]
1004 +[[image:image-20220607171716-9.png]]
1007 1007  
1008 1008  
1009 -
1010 -
1011 1011  (((
1012 1012  (% style="color:#037691" %)**Downlink Command: 0x06**
1013 1013  )))
... ... @@ -1027,10 +1027,20 @@
1027 1027  Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1028 1028  )))
1029 1029  
1026 +(((
1027 +
1028 +)))
1030 1030  
1031 1031  
1032 -== 4.3  Get Firmware Version Info ==
1033 1033  
1032 +== 3.3 Calibrate Sensor ==
1033 +
1034 +Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
1035 +
1036 +
1037 +
1038 +== 3.4 Get Firmware Version Info ==
1039 +
1034 1034  Feature: use downlink to get firmware version.
1035 1035  
1036 1036  (% style="color:#037691" %)**Downlink Command: 0x26**
... ... @@ -1111,12 +1111,12 @@
1111 1111  
1112 1112  
1113 1113  
1114 -= 5.  Battery & How to replace =
1120 += 4. Battery & How to replace =
1115 1115  
1116 -== 5.1  Battery Type ==
1122 +== 4.1 Battery Type ==
1117 1117  
1118 1118  (((
1119 -LLDS12 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1125 +LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1120 1120  )))
1121 1121  
1122 1122  (((
... ... @@ -1126,13 +1126,13 @@
1126 1126  [[image:1654593587246-335.png]]
1127 1127  
1128 1128  
1129 -Minimum Working Voltage for the LLDS12:
1135 +Minimum Working Voltage for the LSPH01:
1130 1130  
1131 -LLDS12:  2.45v ~~ 3.6v
1137 +LSPH01:  2.45v ~~ 3.6v
1132 1132  
1133 1133  
1134 1134  
1135 -== 5.2  Replace Battery ==
1141 +== 4.2 Replace Battery ==
1136 1136  
1137 1137  (((
1138 1138  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
... ... @@ -1144,7 +1144,7 @@
1144 1144  
1145 1145  
1146 1146  
1147 -== 5.3  Power Consumption Analyze ==
1153 +== 4.3 Power Consumption Analyze ==
1148 1148  
1149 1149  (((
1150 1150  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
... ... @@ -1187,7 +1187,7 @@
1187 1187  
1188 1188  
1189 1189  
1190 -=== 5.3.1  ​Battery Note ===
1196 +=== 4.3.1 ​Battery Note ===
1191 1191  
1192 1192  (((
1193 1193  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
... ... @@ -1195,23 +1195,23 @@
1195 1195  
1196 1196  
1197 1197  
1198 -=== ​5.3.2  Replace the battery ===
1204 +=== ​4.3.2 Replace the battery ===
1199 1199  
1200 1200  (((
1201 -You can change the battery in the LLDS12.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
1207 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
1202 1202  )))
1203 1203  
1204 1204  (((
1205 -The default battery pack of LLDS12 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1211 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1206 1206  )))
1207 1207  
1208 1208  
1209 1209  
1210 -= 6.  Use AT Command =
1216 += 5. Use AT Command =
1211 1211  
1212 -== 6.1  Access AT Commands ==
1218 +== 5.1 Access AT Commands ==
1213 1213  
1214 -LLDS12 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LLDS12 for using AT command, as below.
1220 +LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
1215 1215  
1216 1216  [[image:1654593668970-604.png]]
1217 1217  
... ... @@ -1234,9 +1234,9 @@
1234 1234  Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]].
1235 1235  
1236 1236  
1237 -= 7.  FAQ =
1243 += 6.  FAQ =
1238 1238  
1239 -== 7.1  How to change the LoRa Frequency Bands/Region ==
1245 +== 6.1  How to change the LoRa Frequency Bands/Region ==
1240 1240  
1241 1241  You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1242 1242  When downloading the images, choose the required image file for download. ​
... ... @@ -1246,38 +1246,23 @@
1246 1246  
1247 1247  == 8.1  AT Commands input doesn’t work ==
1248 1248  
1249 -
1250 1250  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1251 1251  
1252 1252  
1253 1253  == 8.2  Significant error between the output distant value of LiDAR and actual distance ==
1254 1254  
1260 +Cause ①:Due to the physical principles of The LiDAR probe, the above phenomenon is likely to occur if the detection object is the material with high reflectivity (such as mirror, smooth floor tile, etc.) or transparent substance (such as glass and water, etc.)
1255 1255  
1256 -(((
1257 -(% style="color:blue" %)**Cause ①**(%%)**:**Due to the physical principles of The LiDAR probe, the above phenomenon is likely to occur if the detection object is the material with high reflectivity (such as mirror, smooth floor tile, etc.) or transparent substance (such as glass and water, etc.)
1258 -)))
1259 -
1260 -(((
1261 1261  Troubleshooting: Please avoid use of this product under such circumstance in practice.
1262 -)))
1263 1263  
1264 -(((
1265 -
1266 -)))
1267 1267  
1268 -(((
1269 -(% style="color:blue" %)**Cause ②**(%%)**: **The IR-pass filters are blocked.
1270 -)))
1265 +Cause ②: The IR-pass filters are blocked.
1271 1271  
1272 -(((
1273 -Troubleshooting: please use dry dust-free cloth to gently remove the foreign matter.
1274 -)))
1267 +Troubleshooting: please use dry dust-free cloth to gently remove the foreign matter
1275 1275  
1276 1276  
1277 -
1278 1278  = 9.  Order Info =
1279 1279  
1280 -
1281 1281  Part Number: (% style="color:blue" %)**LLDS12-XX**
1282 1282  
1283 1283  
... ... @@ -1293,6 +1293,7 @@
1293 1293  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1294 1294  
1295 1295  
1287 +
1296 1296  = 10. ​ Packing Info =
1297 1297  
1298 1298  
... ... @@ -1308,6 +1308,7 @@
1308 1308  * Weight / pcs : g
1309 1309  
1310 1310  
1303 +
1311 1311  = 11.  ​Support =
1312 1312  
1313 1313  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
image-20220610105806-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -15.5 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0